My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2415 11TH ST 2019-08-13
>
Address Records
>
11TH ST
>
2415
>
2415 11TH ST 2019-08-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2019 9:49:23 AM
Creation date
8/13/2019 9:49:18 AM
Metadata
Fields
Template:
Address Document
Street Name
11TH ST
Street Number
2415
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC WDIMS <br /> September 13, 2017 <br /> Jeff Sorenson <br /> jsorenson@servproeverettwa.com <br /> SERVPRO <br /> 1830 Bickford Ave. STE 101 <br /> Snohomish, WA 98290 <br /> Owner: Highlander Associates, LLC <br /> Job Address: 2415 11th ST <br /> Plan Check No: B1708-028 <br /> RE: Corrections Letter <br /> Dear Mr.Sorenson, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> General <br /> 1. A listing for the one-hour walls should be provided. IEBC Section 603.1 <br /> 2. A listing for the one-hour floor/ceiling assembly between the upper and lower floors <br /> should be provided. IEBC Section 603.1 <br /> 3. Duct penetrations through a one-hour floor/ceiling assembly should be provided with <br /> ceiling radiation dampers or a shaft. IBC Section 717.6.2 <br /> 4. A manual fire alarm system should be provided for the building if the project does not <br /> fall under an exception provided under IFC Section 1103.7.6 <br /> 5. The locations of smoke alarms within the repaired units should be shown on the plans. <br /> The alarms should be hardwired, interconnected and provided with battery backup. IFC <br /> Section 1103.8 <br /> 6. Carbon monoxide alarms should be shown on the plans. IFC Section 1103.9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.