4 <br /> k <br /> Highlander Apartments Fire Damage Repairs 17264.10 September 18, 2017 <br /> Corrections Notice#1 Response Page 2 of 2 <br /> 7. All dwelling units within the building not affected by the fire will be required to be inspected for <br /> smoke alarms and carbon monoxide alarms prior to final approval. IFC Section 1101.4.2. <br /> We acknowledge and accept this inspection requirement. <br /> 8. The location and sizing of exhaust fans in the bathroom and kitchen should be shown. IMC Section <br /> 403.3.1.1. <br /> The exhaust fans have been added to plan sheets S2.1 and S2.2. <br /> 9. The exterior walls appear to be 2x4 construction.The plans should show that R-15 insulation will be <br /> installed in the exterior wall cavities.WSEC Section R503.1.1. <br /> R-15 insulation has been added as a plan note on plan sheets S2.1 and S2.2. <br /> 10. Draft stops should be provided in the attic space installed above, and in line with walls separating <br /> dwelling units and between dwelling units and stairs. IBC Section 718.4.2. <br /> A note requiring draft stops has been added to plan sheet S2.2. <br /> 11. The roof assembly should be shown insulated up to a maximum amount of R-49.A minimum of 1" of <br /> attic space should be left and shown ventilated. WSEC Section 503.1.1 and IBC Section 1203.3. <br /> Detail 1/54.2 has been revised to show these requirements. <br /> If you have any questions or comments regarding the responses to this review please do not hesitate to call. <br /> Sincerely, <br /> CG Engineering <br /> gym/ W404....._ <br /> Mike Maechler, PE,SE <br /> Project Manager <br /> 250 4th Avenue South,Suite 200 <br /> Edmonds,WA 98020 <br /> ENGINEERING ph.425.778.8500 I f.425.778.5536 <br /> www.cgengineering.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.