DOOR SCHEDULE <br /> DOOR SW NG �EGEND GE�IERAL FRANIE AND DOOR NOTES � <br /> DOOR DOOR SIZE TYPE MATL FINISH RATING FRAME FRAME FRAME HDW DETAILS NOTES INSIDE INSIDE <br /> MARK (MIN.) TYPE MATL FINISH GROUP HEAD JAMB SILL RH LOCK LH LOCK 1. PROVIDE FRAMES WITH THROATS TO ACCOMMODATE WALLS IN WHICH DOORS <br /> �rFy ,��,y <br /> ARE LOCATED, EXCEPT WHERE INDICATED OTHERWISE ON PLAN DETAILS. <br /> 17K3 3'-0"X7'-0" A HM PT. - A HM PT. 1 1 A354 2 A354 - RH HINGE LH HINGE 2. CLOSERS SHALL BE PROVIDED ON LABELED DOORS. <br /> RH HAND JAMB JAMB LH HAND � <br /> STRIKE JAMB STRIKE JAMB <br /> � � 3. ALL DOORS SHALL BE 1 3/4" THICK UNLESS OTHERWISE NOTED. � <br /> OUTSIDE OUTSIDE 4. SEE DOOR SCHEDULE FOR DOOR AND FRAME FINISHES. DOOR EDGES TO � <br /> RH DOOR (SWING IN) RH FRAME LH DOOR (SWING IN) LH FRAME MATCH FINISHES OF DOOR SURFACES. � <br /> 5. WOOD DOORS TO BE STAINED DARK CHERRY TO MATCH CONTROL SAMPLE. <br /> HARDWARE GROUPS : HARDWARE NOTES . INSIDE �NS�oE <br /> 6. NOT USED. <br /> � � 7. DOOR OPENINGS ARE 6" FROM ADJACENT PERPENDICULAR WALLS, OR <br /> GROUP 1 GENERAL HARDWARE NOTES: LH STRIKE RH STRIKE - <br /> 1 . PROVIDE ALL LOCKSETS LESS CYLINDER, TYPICAL. JAMB LH RH JAMB CENTERED IN ROOM, UNLESS DIMENSIONED OTHERWISE. `� <br /> '4; , <br /> HINGES STANLEY FBB179 x 4.5 x 4.5 X US26D RHRB LOCK y HINGE JAMB HINGE JAMB � LHRB LOCK 8. GLASS GLAZING. ' <br /> EXIT DEVICE VON DUPRIN 99E0 x 36" x US26D HARDWARE NOTES: `�� OUTSIDE OUTSIDE FY A. UNCOATED CLEAR HEAT TREATED FLOAT GLASS: ASTM C1048, <br /> DOOR CLOSER YALE 4400 LN 689 CONDITION A (UNCOATED SURFACES), TYPE I (TRANSPARENT • <br /> 1 . PROVIDE US 26D FINISH: SATIN CHROME RIGHT HAND REVERSE BEVEL DOOR LEFT HAND REVERSE BEVEL DOOR <br /> DOORSEAL PEMKO S88D x 17' (SWING OUT) LEFT HAND FRAME (SWWG OUT) RIGHT HAND FRAME GLASS, FLAT), CLASS I (CLEAR) QUALITY q3 (GLAZING SELECT), <br /> 2. PROVIDE CUTOUTS FOR SPECIFIED HARDWARE. KIND FT FULLY TEMPERED AT DOOR LITES, DOOR SIDELITES AND <br /> WALL STOP IVES #4 1/2" X US26D � ) <br /> KICK PLATE TRIMCO K0050.630 x 12" x 34" 3. PROVIDE WALL STOPS IF WALL IS ADJACENT AT 90 DEGREES RH INSIDE LH RH INSIDE LH TRANSOMS AND ELSEWHERE AS REQUIRED OR INDICATED, EXCEPT <br /> FROM DOOR +/-. PROVIDE FLOOR STOPS AT OTHER HINGE JAMB HINGE JAMB HINGE JAMB HINGE JAMB AT RATED LOCATIONS. <br /> LOCATIONS. JNAC�TI�VE � � INACTIVE _ THICKNESS:1/4" EXCEPT 3/16" AT LITES IN DOORS. <br /> LH RH <br /> ASTRAGAL ASTRAGAL B. GLAZING FOR 20-MINUTE RATED ASSEMBLIES: POLISHED <br /> 3 5/8" x 18 GA. „ LHRB ACTIVE FY ��`RHRB ACTIVE WIRE GLASS PER ASTM C1036 TYPE II (PATTERNED AND WIRED � <br /> D 0 0 R TYP ES FRAM E TYP ES STL STUDS AT 16 o.c. OUTSIDE OUTSIDE GLASS FLAT), CLASS I (CLEAR) QUALITY q8 (GLAZING); 6.4MM <br /> SCALE: 1 4"=1 '-0" SCALE: 1 4"=1 '-0" 5/$" GWB EA. SIDE PAIR DOORS - LHRB ACTIVE PAIR DOORS - RHRB ACTIVE THICK. PROVIDE FORM I (WIRED, POLISHED BOTH SIDES), WITH M2 � <br /> „ / „ �_ ��/ <br /> 3 0 (SWING OUT)DBL DR FRAME-RH ACT. (SWING OUT)DBL DR FRAME-LH ACT. SQUARE MESH. <br /> 6 8 � <br /> INSIDE INSIDE 9. ADJUST EXIST. DOORS WITHIN AREA OF WORK TO ACHIEVE POSITIVE <br /> o LH ACTIVE RH ACTIVE LATCHING. <br /> � � <br /> BOX HEADER PER STRUCTURAL ��-y INACTIVE INACTIVE �FY 10. EXISTING PAINTED DOORS AND FRAMES TO REMAIN SHALL BE CLEANED <br /> N o R�� � LH _ AND RE-PAINTED, AND EXISTING STAINED WOOD DOORS SHALL BE CLEANED � <br /> � _ . .. 16 GA. HM FRAME LH HINGE ASTRAGAL RH HINGE LH HINGE ASTRAGAL RH HINGE AND RE-STAINED TO MATCH NEW DOORS, PER SPEC. SECTION N0. 09900 r <br /> JAMB JAMB JAMB JAMB WHERE INDICATED ON DOOR SCHEDULE. <br /> 3/16" TEMPERED OUTSIDE OUTSIDE <br /> GLASS LITE PAIR DOORS — LH ACTIVE PAIR DOORS — RH ACTIVE 11 . DOOR MARKS ARE ASSIGNED RELATIVE TO THE MAJOR BUILDING—GRID BAY IN <br /> GROUT SOLID (SWING IN)DBL DR FRAME-LH ACT. (SWING IN)DBL DR FRAME-RH ACT. WHICH THE ELEMENT OCCURS. THE DOOR MARK IS COMPOSED AS FOLLOWS: <br /> A KICKPLATE /� 18 GA. HM DOOR �103B6� <br /> n <br /> HM FLOOR NUMBER �� GRID NUMBER TO NW <br /> SEQUENCE NUMBER GRID LETTER TO NW <br /> ,q DOO R H EAD JAM B 12. DOOR FRAMES HUNG WITH LABELED DOORS SHALL ALSO BE LABELED TO <br /> MATCH THAT OF DOOR FOR OVERALL ASSMEBLY RATING. <br /> A354 A354 SCALE: 1 1/2" = 1 '-0" <br /> �. <br /> ISSUED FOR PERMIT ' � <br /> rolluda arch �tects � ����� <br /> Q7. � 3. � 7 architecture planning interior design ^ <br /> 105 South Main Street,Suite 323,Seattle,WA 98104 206.624.4222 � <br /> ri-j - <br /> � <br /> ACCEPTABILITY EC ROLLUDA �06.01.�7 SUBTITLE DOOR SCHEDULE DOOR & FRAME TYPES CURRENT REVISION SYMBOL — DATE o ,;� <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE N , <br /> — IRC — WBS 2.2.3.1.4 INTEGRATED PAINT FACILITY W2572915 C/ROLLUD 07.13.17 sso4 THIS DESIGN AND/OR CHECKED HARDWARE SCHEDULE � W2572915 ��.�3.17 � }'t <br /> GISTERED SPECIFICATION IS APPROVED SHEEf � <br /> � A HITECT N INEER TITLE IRC - WBS 2.2.3.1 .4 INTEGRATED PAINT FACILITY � <br /> BOE,�� APPROVED BY DEPT. DATE � , <br /> � CHECKED A3 54 N <br /> R'� � T BUILDING 40-056 <br /> STATE OF WASHINGTON APPROVED JOB N0. COMP N0. o <br /> W2572915 -� � <br /> � <br /> APPROVED ARCHITECTURAL MASTER EVERETT, Wq °wc No. 40-056-A354 <br />