<br /> EXISTING 5/8" GWB
<br /> TWO PIECE BONNET, 24 GA. VENT PIPE SUPPORT CHEMLINK SEALANT
<br /> SEAIANT JOINT GALV. STEEL MIN. SEALANT JOINT NOTE: PROVIDE 12" MIN. TYPE M-1 OR DURALINK EXISTING 10" METAL STUDS,
<br /> STAINLESS STEEL PREFABRICATED INSULATED CLEAR FROM ALL HUNG FROM STRUCTURE
<br /> STAINLESS STEEL STAINLESS STEEL ABOVE, MODIFY FOR NEW
<br /> CLAMPING BAND � � LINER AND I WOOD NAILER CLAMPING BAND OBSTRUCTIONS CLAMPING BAND OPENING HEIGHT
<br /> CLEAR OPENING � � � FLASHING MEMBRANE , PORTALS PLUS PVC BOOT . ._ 5/8 GWB, PATCH AND -
<br /> FLASHING MEMBRANE SET � SET IN BONDING � ` OR APPVD SUBSTITUTE �� � PAINT TO MATCH EXISTING
<br /> REF. STRUCT. DWGS. �� w N IN BONDING ADHESIVE i ADHESIVE Q ' 0� _ ;.' f
<br /> F A S T E N A T TERMINATION BAR FASTENED ' H O T A I R W E L D � W H I T E K N I G H T S I N G L E ':.
<br /> 12" O.C. W/ SCREW AND MEMBRANE � z � COMPONENT URETHANE ^: MTL. TRACK PER STRUCT.
<br /> Z AI,R BARRIER WRAPPED K � � , „ •. SEE SHT. 7/S553 3
<br /> SET IN ALL-PURPOSE SEALANT � � 4 BACK ON TOP OF
<br /> � z - ' INSUL. AND SEALED N I FABRIC E RE N�FORCEM E N MIN. 6 �'
<br /> � � SEAM SEALANT � � � T ��
<br /> Q � o � ROOF MEMBRANE A.F.F. '� � . - -
<br /> AIR BARRIER WRAPPED �
<br /> ,.. .- :- ... •. •:. •.
<br /> ... { �• :. i �. � .. .r��:;��'.. i.
<br /> .. ` . . • .•
<br /> . . . ... .. . .. . .. . . .: : :
<br /> �`-� � , - �-� � � i � MTL. STUD SECTION PER STRUCT. � i i �
<br /> � � 4�� 4" BACK ON TOP OF i s , , SEE SHT. 7/S553-3 , , , �
<br /> z
<br /> �
<br /> NOTES: � � � INSUL. AND SEALED _________ _ , ____ ____ ,� _ -� I ,k ; I ; ; • ; ; ; ; -
<br /> 1 . VERIFY ROOF N � ROOF MEMBRANE � � z . �
<br /> , � � i i i i REMOVE LOWER PORTION OF � i i i i
<br /> INSULATION THK. � I � I ! ! � � �- EXISTING WALL AS REQUIRED � ! ! ! ! r
<br /> W/ REVIEWED SHOP i� i ROOF INSULATION EXISTING � NON-PVC SINGLE `�' FOR NEW OPENING HEIGHT �
<br /> DWGS. OF ROOF +� ____ ___ ______ _ __ � (R=30) ROOF SYSTEM PLY ROOF MEMBRANE �
<br /> WSUL. SUBMITTAL � I MTL. ROOF DECK , , � � � ;I � ; f'
<br /> 2. CURBS TO BE , ' �� --�--�---� � � �I� _—__— _ _—__�,
<br /> AIR BARRIER BETWEEN ! !! I I
<br /> FAB R I CATE D W/ ( D EC K AN D I N S U LATI O N � -- ^^-- ---' '--"-- '----' ---- ""--^ L__--_ __ ____� ______ ____ �___ J
<br /> SLOPING BOTI-OMS ROOF INSULATION INSTALLATION NOTES: _ �
<br /> AND LEVEL TOP � (R=30) VENT STACK -REF. 1 . CLEAN SINGLE PLY MEMBRANE AN BOOT WITH MEK OR ACETONE TYPE SOLVENT. � � _
<br /> � (E) MTL. ROOF DECK MECH. DWGS. FOR 2. APPLY BASE COAT OF WHITE-KNIGHT URETHANE COATING TO ROOF SURFACE � NOTE: PATCH JAMB EA. SIDE � � "
<br /> EXHAUST STACK � SIZE EXTENDING PAST BOOT BASE A MINIMUM OF 4". � � W/ 5/8" GWB AND PAINT � z -
<br /> REF: MECH. DWGS. � A I R B A R R I E R B E T W E E N 3. I N S T A L L B O O T I N T O B A S E A N D A P P L Y A D D I T I O N A L W H I T E-K N I G H T T O B A S E O F B O O T. T O M A T C H � w �
<br /> DECK AND INSULATION X �
<br /> DETAILS 8/M558 � 4. EMBED POLYESTER REINFORCING FABRIC INTO WHITE-KNIGHT COATING AT BOOT w o � �
<br /> AND 2/M588 STEEL PURLIN -REF: BASE EXTENDING TO ROOF SURFACE A MINIMUM OF 3".
<br /> STRUCT. DWGS. 5. APPLY TOPCOAT OF WHITE-KNIGHT TO COMPLETELY EMBED REINFORCING FABRIC.
<br /> PROVID�TGUYW REK SUPPOR� 6. INSTALL HOSE CLAMP ANQ APPLY SEALANT TO TOP OF BOOT. H EA D E R D ETA I L 4A H EA D E R D ETA I � q-B f
<br /> AND ANCHORAGE. SCALE: 3"=1 '-0" - A616 SCALE: 3"=1 '-0" - A616
<br /> EXHAUST STACK PIPE PENETRATION RETROFIT PIPE PENETRATION
<br /> DETAI � � DETAI � � FLASHING BOOT DETA � �
<br /> SCALE: 1 1/2"=1 '-0" A616 SCALE: 1 1/2"=1 '-0" A616 SCALE: 1 1/2"=1 '-0" A616 CURB MOUNTED
<br /> � � �
<br /> EQUIP. REF: .
<br /> MECH. DWGS.
<br /> BLOCKED OPENING CLEAR OPENING � NRE�F ABRI�CATED
<br /> PER STRUCTURAL REF. STRUCT. DWGS. CURB W/
<br /> 1 '-8" CORREGATED INTERIOR MTL.
<br /> HEAD FLASHING METAL WALL 1/4" X 4"� STEEL CAP
<br /> ;---- -------- - ----------------------------- - -------- ----; LI N E R A N D
<br /> �� ; + -� + ; WELDED TO VERTICAL. Il WOOD NAILER
<br /> SEALAN T � ' �---------------------------------------------- ; H EAD FLASH I N G r� FLA S H I N G
<br /> ; ; ; � �--- 4" DIA. STL.
<br /> ; ; ; , MEMBRANE
<br /> � '
<br /> PIPE GUARDPOST FASTEN AT SET IN BONDING
<br /> � � ,
<br /> ; ; � ; 14" DIA. PIPE FILL WITH CONC. 12" O.C. ADHESIVE k
<br /> I � � � � t .
<br /> i i �
<br /> i i i � O •
<br /> I TERMINATION
<br /> � ' � ' ' BLOCKED OPENING � WAR S REW N ED •
<br /> � ' ' �
<br /> � ; �
<br /> `- ; i i � BEYOND PER STRUCT. „ „ „ � AND MEMBRANE
<br /> z ; � ; ; 9 X9 X1/2 STL. - - SET IN ALL-
<br /> , , , ,
<br /> � ' ' ' ' PLATE W/ (4) 1/2" DIA. PURPOSE SEALANT
<br /> �
<br /> Q ' ' i � STEEL ANGLE »
<br /> FLASHING PLATE I_ � � ' ' ' FRAMING BEYOND x 3 1/4 EMBED EXP. BOLTS SEAM SEALANT
<br /> o � ; :
<br /> II L_____________________________________________J � . _
<br /> J � '
<br /> �� �� � ; ; 3/16 AIR BARRIER �` �
<br /> 14 DIA. DUCT = ; + + + ; SILL FLASHING Q 4>>
<br /> WRAPPED �'
<br /> SILL FLASHING SEE MECH. � �_ �
<br /> ------------- - ----------------------------- - ------------- ,
<br /> � �- 4" BACK k �
<br /> � z °- o ON TOP OF
<br /> '�' � _ � INSUL. AND .
<br /> PAINT SAFETY YELLOW � ,L SEALED
<br /> 00 = o
<br /> �
<br /> PENETRATI0 �1 DETAIL - SECTION 5 PENETRATI0 �1 DETAI � - E �E�ATION 6 DETAI � ROOF MEMBRANE
<br /> . „ , „ . „ , „ . „ , g K �
<br /> SCALE. 1 1/2 =1 -0 - A616 SCALE. 1 1/2 =1 -0 -
<br /> - A616 SCALE. 1 1/2 =1 -0 1 A10-42 A616
<br /> �
<br /> NOTE: PROVIDE ALECO STRIP DOOR OR
<br /> EQUAL STANDARD CLEAR PVC STRIPS,
<br /> EXIST. HEADER 12" X 0.120" SMOOTH, OVERLAP 50�, � PANEL (480V, 120V, FHC, ETC) NOTES: � ,�
<br /> UNIVERSAL MOUNTING SYSTEM ALUMINUM �
<br /> 1 . VERIFY ROOF �
<br /> FOR SIDE-WALL OR LINTEL MOUNTING, J INSULATION THK. �
<br /> z W/ REVIEWED ROOF
<br /> - R : -800-633-1320, � INSULATION
<br /> _ - _ _ _ _ EMAIL: INFOt�ALECO.COM, Q SHOP DWGS. I R-30
<br /> WEB: WWW.ALECO.COM � �- •
<br /> > z ¢ � > 2" YELLOW STRIPE � ( - )
<br /> FREEZER STRIP o 0 0 = o OF ROOF I
<br /> BRACKET � �' J� �' 2. CURBS TO BE ' �
<br /> CONTRACTOR VERIFY HT. _ '�-' I
<br /> � � Q � � �- Q FABRICATED W/ � MTL. ROOF - _
<br /> a SLOPING BOTTOMS DECK
<br /> APPROX. 27' A.F.F. N m Q� � 3" LETTERING, HELVETICA, AND LEVEL TOP
<br /> STL. BEAM � � � '� CENTERED AND 3" FROM BORDER � �
<br /> CONTRACTOR VERIFY HT ATTACH TO STL. BEAM W/ 7/16" Q � 3. CURB THICKNESS I AIR BARRIER �
<br /> EXIST. HEADER DIA. WELDED THREADED STUDS - KEEP CLEA TO BE DETERMINED � BETWEEN DECK _
<br /> FREEZER STRIP APPROX. 8' 8c 16' A.F.F. FREEZER STRIP @ 16" O.C. � BY CURB MANUF. I AND INSULATION .
<br /> BRACKET FOR LOAD SUPPORTED �
<br /> �
<br /> ATTACH TO EA. STUD W/ 7/16" DIA. FREEZER STRIP
<br /> CENTER BOLT ON STUD AND LOCATE 4" � STEEL PURLIN -
<br /> MIN. ABOVE BOTTOM OF STUD. FIE�D VFY. WIDTH OF PNL. (36"MIN.) GEN. NOTE: STACK MFR. TO REF: STRUCT.
<br /> STUD LOCATIONS AND SPACING PRIOR TO PROVIDE GUYWIRE SUPPORT DWGS.
<br /> FABRICATION OF CONNECTION BRACKET AIR INTAKE AND ANCHORAGE.
<br /> DETAI � � � .
<br /> FREEZER STRIP @ FREEZER STRIP @
<br /> , , SCALE: 3"=1 '-0" - A616
<br /> H EAD ER D ETAI � 7 ST�. B EAM D ETA � K EEP C �EAR D ETAI � AT PA�I E�S � � ISSUED FOR PERMIT �
<br /> ,, , ,� . ,, , » cite �
<br /> �
<br /> SCALE: 3 =1 -0 - A616 SCALE. 3 =1 -0 - A616 SCALE: N.T.S. - A616 ^
<br /> �7. 1 �. � 7 architecture planning interior design N -
<br /> 105 SouM Main Street,Suite 323,Seaitle,WA 98104 20o.624A222 N
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABIL DRAWN DATE SUBTITLE CURRENT REVISION SYMeo� DATE N .
<br /> _ fiso4 THIS DESIGN AND OR CHECKED MISCELLANEOUS DETAILS W2572915 K o7.13.17 ,
<br /> K IRC - WBS 2.2.3.1.4 INTEGRATED PAINT FACILITY W2572915 C/ROLLUD 07.13.17 E IRC WBS 2.2.3.2.5 PARTITIONS (1 PP/2SF/5MB) W2572915 RAI 09.23.15 GISTERED � �
<br /> SPECIFICATION IS APPROVED SHEEf �
<br /> F IRC-WBS2.2.3.1.5 CURING OVENS-HAND LAYUP W2572915 RAI 02.03.16 � A HITECT APPROVED BY DEPT. DATE NGINEER TITLE IRC — WBS 2.2.3.1 .4 INTEGRATED PAINT FACILITY
<br /> ° A616 �
<br /> B IRC - WBS 2.2.3.1.8 - CLV VACUUM PUMPS W2572915 RAI 09.17.15 G IRC-WBS2.2.3.1.5CURING OVENS-HAND LAYUP-DCN2 W2572915 RAI 03.10.16 RIC C T CHECKED � '
<br /> STATE OF WASHINGTON APPROVED �U I LD I N G 40��� JOB N0. COMP N0. m
<br /> C IRC - WBS 2.2.3.2.21-VACUUM FORMS (4MC)-DCN W2572915 RAI 09.23.15 H IRC-WBS 2.2.3.2.9 LININGS (1 SF, 1 LB) W2572915 EC/ROLLUDA 06.29.16 W2572915 0
<br /> �
<br /> D IRC - WBS 2.2.3.2.31 PARTITIONS (3MB) W2572915 RAI 08.26.15 J ADDITIVE MANUFACTURING (3D PRINT SHOP) W2572915 C/ROLLUD 10.26.16 APPROVED ARCHITECTURAL MASTER EVEREIT, �IA °wc r,o. 40-056-A616
<br />
|