My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
319 76TH ST SW T MOBILE ANTENNA 2019-08-14
>
Address Records
>
76TH ST SW
>
319
>
T MOBILE ANTENNA
>
319 76TH ST SW T MOBILE ANTENNA 2019-08-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2019 7:49:48 AM
Creation date
8/14/2019 7:49:43 AM
Metadata
Fields
Template:
Address Document
Street Name
76TH ST SW
Street Number
319
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL NOTES: <br /> 1. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL 11 ■M o b i 1 e <br /> CODE AND ANY LOCAL,CITY,OR COUNTY CODES THAT MAY APPLY. <br /> 2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. <br /> 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PERMITTING,FILINGS,INSPECTIONS,AND TESTING AS REQUIRED BY THE -PROJECT INFORMATION: <br /> PERMITTING AUTHORITY AND T-MOBILE. <br /> 4. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT,SCHEDULE 40,TYPE 1,CONFORMING TO UL EVERETT WATER TANK <br /> ARTICLE 651; MANUFACTURED BY WESTERN PLASTICS,CARLON,OR EQUAL.ALL BENDS SHALL BE 30"MINIMUM RADIUS. SE01605A <br /> 5. CONTRACTOR SHALL CONTACT ALL UTILITIES FOR LOCATION OF UNDERGROUND SERVICES.SERVICE LOCATIONS TO BE <br /> CONFIRMED PRIOR TO CONSTRUCTION. 319 76TH ST SW <br /> EVERETT,WA 98201 <br /> 6. ALL EQUIPMENT,WIRING,AND MATERIALS MUST HAVE A UL LABEL. <br /> 7. WIRES AND CABLES SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITH NO SPLICES ALLOWED. -ISSUED FOR: <br /> 8. ALL JUNCTION AND OUTLET BOXES SHALL BE LABELED WITH KROY TAPE OR EQUAL.CONTRACTOR TO DESIGNATE ALL BUILDING PERMIT <br /> CIRCUIT NUMBERS CONTAINED IN EACH BOX. <br /> -REVISION HISTORY: <br /> CHK <br /> 9. THE DISTRIBUTION PANEL SHALL HAVE A TYPED LEGEND IDENTIFYING THE LOADS OF ALL CIRCUIT BREAKERS. NO. DATE: DESCRIPTION: BY: <br /> 10.CONTRACTOR SHALL INSTALL CONDUIT SEALING COMPOUND(BLACKBURN DX DUCT SEAL OR EQUAL)AFTER WIRING IS <br /> PULLED AND TERMINATED. <br /> (P)(3)#3 THWN W/(1)#8 GRN <br /> GRD IN 1-1/2"U/G PVC CONDUIT- <br /> (P)100 AMP 120/240V 18 <br /> AUTOMATIC TRANSFER SWITCH GENERATOR RECEPTACLE <br /> (SERVICE RATED) WITHIN POWER CABINET <br /> (P)100 AMP DISCONNECT <br /> (SERVICE RATED) (E)100 AMP PANEL <br /> 100/2 F <br /> (E)100AMPSERVICE METER I <br /> 0 WALKING BEAM ItJITERLOCK <br /> I 100/2 100/2 <br /> (E)100 AMP METER BASE I I , \ 9/5/2018 REVISED PER REDIJNES BJT <br /> (P)(3)#3 THWN IN 1-1/2"PVC CONDUIT I I A 8/22/2018 ISSUED DESIGN REVIEW BJT <br /> 100/2 30/2 30/2 20/1 20/1 <br /> (P)(3)#3 THWN W/(1)#8 GRN - _ _ - - - =PLANS PREPARED BY: <br /> GRD IN 1-1/2"U/G PVC CONDUIT <br /> (P)(3)#3 THWN W/(1)#8 GRN O GROUND PER NEC B. J.THOMAS, P.E. <br /> GRD IN 1-1/2"U/G PVC CONDUIT RECEPTACLE 7607 80TH AVE NE <br /> RECTIFIER TELCO MARYSVILLE,WA 98270 <br /> RECTIFIER TRAY2 206-851-1106 <br /> (P)GENE RAC#RG025 25KW GENERATOR TRAY 1 <br /> -DRAWN BY: CHK.BY: <br /> ELECTRICAL ONE LINE JL BJ <br /> 4 <br /> LICENSURE: <br /> wAsi <br /> ibto:rhadr. <br /> =DRAWING INFORMATION: <br /> DO NOT SCALE DRAWINGS.COMRACTOR MUST VERIFY <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF <br /> DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR <br /> DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED <br /> CLIENT IS STRICTLY PROHIBITED. <br /> =DRAWING TITLE: <br /> ELECTRICAL <br /> DETAILS <br /> =DRAWING NUMBER:- <br /> E. 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.