My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
319 76TH ST SW T MOBILE ANTENNA 2019-08-14
>
Address Records
>
76TH ST SW
>
319
>
T MOBILE ANTENNA
>
319 76TH ST SW T MOBILE ANTENNA 2019-08-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2019 7:49:48 AM
Creation date
8/14/2019 7:49:43 AM
Metadata
Fields
Template:
Address Document
Street Name
76TH ST SW
Street Number
319
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x GROUNDING NOTES: <br /> 1. GROUNDING SHALL COMPLY WITH LATEST EDITION OF THE NATIONAL <br /> ELECTRICAL CODE. T ■ ■M o b •i l e <br /> x <br /> I 2. MINIMUM BENDING RADIUS FOR GROUND CONDUCTOR IS 8". <br /> x 3. NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br /> •• a o =PROJECT INFORMATION: <br /> � p 4. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINTATTHEIR <br /> x ° q ° MATING SURFACES AND INSTALLED PER MANUFACTURER'S EVERETT WATER TANK <br /> 4 4 RECOMMENDATIONS. USE PE NETROX OR EQUIVALENT ANTIOXIDANT <br /> q• p • 4 ® GREASE. SE01605A <br /> 5. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG COMPRESSION <br /> 319 76TH ST SW <br /> x d • TYPE. STACKED CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK EVERETT,WA 96201 <br /> CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BAR WILL BE <br /> PERMITTED. <br /> C 1� \ -ISSUED FOR: <br /> xI -�+,",+,�r4—"—`//��-; 6. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE <br /> a' ® 'ice+'�.�i.e �`��i�i'."40:.►�: MANUFACTURERS SPECIFIED VALUES. BUILDING PERMIT <br /> •.-0j"j��� roMpOte!4"imow: _ <br /> x p Q A ® I a ;\ �/ 7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BYATLEAST6". —REVISION HISTORY: <br /> CH <br /> ° • q � _ �� NO. DATE: DESCRIPTION: BY: <br /> 8. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT <br /> x q . EXCEED A RESISTANCE OF 5 OHMS TO EARTH. <br /> p . ° q 9. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY METAL <br /> x • •q '• N. <br /> p .'q, •• OBJECTS OR SUPPORTS; TO PRECLUDE ESTABLISHING A"CHOKE"POINT. <br /> Iq ° q . • . <br /> • • a fl 10. GROUND BARS SHALL NOT BE FIELD MODIFIED. <br /> x q p' <br /> J q p Q 11. GROUND RING BURIAL DEPTH SHALL BE 30". <br /> CN <br /> + ® < , 0 �n 12. A CERTIFIED CONTRACTOR WILL MAKE ALL MEASUREMENTS REQUIRED TO <br /> / . . I I I TEST THE GROUNDING SYSTEM USING A MEGGER OR EQUIVALENT.THE <br /> 4 •4 U I ACCEPTABLE RESISTANCE MEASURED FOR THE GROUNDING SYSTEM WILL <br /> / NOT EXCEED 5 OHMS RESISTANCE. THREE DISTANCES SHALL BE USED:1 <br /> y. •• _ AT 100 FEET,1 AT 70 FEET,AND 1 AT 35 FEET.THESE DISTANCES ARE <br /> ® SUBJECT TO A SITE BY SITE BASIS. T-MOBILE-WTS SHALL BE GIVEN 24 <br /> (P)MECHANICAL CONNECTION HOURS NOTICE. ALL COSTS ASSOCIATED WITH GROUND TESTING WILL BE <br /> AT THE EXPENSE OF THE CONTRACTOR. <br /> /-- / \ 9/5/2018 REVISED PER REDLINES BJT <br /> d' BOND FROM(P)GENERATOR SYMBOL LEGEND: /1\ 8/22/2018 ISSUED DESIGN REVIEW BJT <br /> + ° TO(E)SITE GROUND RING MGB —PLANS PREPARED BY: <br /> \+ Tr GROUND BAR <br /> \ J B.J. THOMAS, P.E. <br /> + • CADWELD 7607 80TH AVE NE <br /> 1 MARYSVILLE, WA 98270 <br /> x • MECHANICAL CONNECTION 206.851.1106 <br /> COPPER GROUND ROD -DRAWN BY.—CHK.BY: <br /> 0 GROUND INSPECTION WELL JL BJ <br /> -LICENSURE: <br /> / EXPOSED WIRING <br /> ITHOS <br /> 6,)"....,z,/, <br /> UNDERGROUND WIRING OF WIT,,9S <br /> IB r <br /> ',.'•., <br /> X <br /> x BOND FROM(P)PROPANE TANK <br /> TO(E)SITE GROUND RING <br /> —DRAWING INFORMATION: <br /> X DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF TMS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF <br /> DOCUMENTS IS PROPRIETARY BY NATURE AIN(USE OR <br /> DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED <br /> CLIENT IS STRICTLY PROHIBITED. <br /> ELECTRICAL GROUNDING PLAN <br /> DRAWING TITLE: <br /> 22x34 SCALE:1/2"=1' <br /> DE 11x17 SCALE:1/4"=1' <br /> ELECTRICAL <br /> GROUNDING PLAN <br /> =DRAWING NUMBER: <br /> E-2 <br />