My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 WALL ST IMAGINE CHILDRENS MUSEUM 2018-01-01 MF Import
>
Address Records
>
WALL ST
>
1502
>
IMAGINE CHILDRENS MUSEUM
>
1502 WALL ST IMAGINE CHILDRENS MUSEUM 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 2:54:05 PM
Creation date
8/21/2019 2:53:28 PM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1502
Tenant Name
IMAGINE CHILDRENS MUSEUM
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
266
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />Ltr. D.Olson (B0306-025) <br />June 27, 2003 <br />Page 2 <br />5. The wood used in the exterior wall details on Sheet A8.3 should be shown to be fire- <br />retardant treated. Section 503.43 <br />6. It should bc noted that all full-height glazing in window type BB is required to be safety <br />glazing. Section 2406.4 <br />7. The guardrail surrounding the central stairs should be shown to be a minimum of 42" high. <br />Section 509.2 <br />8. The iloors in the toilet rooms should be shown to exiend up a minimum of 5" onto the wall <br />surface. Section 307.1.1 <br />9. Hall 125 shauld be relabelc�l as a corridor. Section 1004.3.4 <br />10. Maximum occupant load signs must be posted in Rooms 124, I l9 and the main Floor. The <br />signs and vcrbagc should be shown on the plans. Section 1007.2.6 <br />1I. Door #302 should swing in the direction of travel and be provided with panic hardware. <br />Sections 1007.2.5, 1003.3.1.5 & ]003.2.2.2.4 <br />l2. The details of conswction should be completed for the lighthousc. <br />13. The hot water supplies and drains under the accessible lavatories should be shown recessed, <br />insulated or guarded against contact. Section 1106.I IJ.4 <br />Please prepare a responsc Iettcr showing where each item in this correction letter is addressed on the <br />plan set. <br />Upon resubmission of the drawin�s, your application will be given prioriry and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient intorma[ion to ensure that <br />the proposed stnicture will be conshucted in compliance with all adopted codes. <br />Sincercly, <br />��� <br />Tony R. Lce <br />Plans Examiner <br />
The URL can be used to link to this page
Your browser does not support the video tag.