My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 WALL ST IMAGINE CHILDRENS MUSEUM 2018-01-01 MF Import
>
Address Records
>
WALL ST
>
1502
>
IMAGINE CHILDRENS MUSEUM
>
1502 WALL ST IMAGINE CHILDRENS MUSEUM 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 2:54:05 PM
Creation date
8/21/2019 2:53:28 PM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1502
Tenant Name
IMAGINE CHILDRENS MUSEUM
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
266
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Botesch, Nash & Hall <br />Architects, P.S. <br />Juiy 1, 2003 <br />I�Ir. Tony Lee, Plans Examiner <br />City of Everelt <br />3200 Cedar Street <br />Everett, WA, 98201 <br />RE: Children's Museum in Snohomish County <br />Response lo Plan Review Comments <br />Job No. 1316 <br />Dear Tony: <br />The following are our response to your plan review comments. <br />1. The coversheet should note that the basement is also an A-3 occupancy. Section 303.2. <br />The occupancy for the basement has been changed to an A-3 per Section 303.2. <br />2. The coversheet should nole that the type of construction is Iil 1-HR with sprinkler <br />substitution in lieu of one-hour fire-resistive construction (this is an occupancy <br />requiremenl). Section 508 and 302.2.2 <br />The construction type has been changed to type lll 1-HR with sprinkler su6stitution in <br />(ieu of one-hour fire-resistive construction. <br />3. The listings o( the fire-rated walls/partitions should be shown on the plans. Section <br />703.1 <br />Fire-ratings have been added to slieet A5.0 as required by Section 703.1. <br />4. The horizontal exit uses a combination of existing wall, wall type A4 on the exterior, and <br />wall type A3 on the interior. Building Section 3/A6.0 shows that the existing wall is <br />discontinuous (at least at the old glazing areas). A wall of at least two-hour fire resistive <br />construction should be provided at those locations — Wall type A3 is only sufficient for up <br />to one-hour construction. Section 1005.3.5.2 <br />The interior wall type has been changed to wall rype A4 to meet the two-hour fire <br />resistive construction rating. Th�s wall will extend from linish floor to the underside of <br />the structural framing above. The wall type has been changed on sheets A1.1 and <br />A 1.2. <br />5. The wood used in the exterior wali details on sheet A8.3 should be shown as fire- <br />retardant treated. Section 503.4.3 <br />The wood used in the exterior wall details on Sheet A8.3 has 6een changed to metal <br />sfud framing to meet ihe requirements on Section 503.4.3. <br />6. It should be noted that all full-height glazing in window type BB is required to be safety <br />glazing. Section 2406.4 <br />The glazing type in window BB has been changed to tempered glazing as noted on <br />sheet A9.0. <br />i� <br />S\1J16A�CIrilJren s Mvsaum BuilJinq�Docvnrents\Ltllers0.ee Lalin O1L1-XMJ.Doc <br />2915 Hewitt Avenue • E�er,:lt, VJA 98201 • 425•259•OB68 • 425•774•3341 • Fax 425-252-4334 • e-mail bnhWbnharch.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.