Laserfiche WebLink
Permit#: C2010-W2 <br />Site Address: 3618 SHORE AVE <br />Owner: CASCADE GENERAL CONTRACTING INC <br />Tenant: [TenNamel <br />GENERAL NOTES <br />GENERAL REQUIREMENTS <br />ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), <br />INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, <br />INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE <br />AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. <br />THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO <br />CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND <br />WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE <br />RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER <br />REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. <br />THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR <br />CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR <br />DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL <br />BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND <br />WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING <br />COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE <br />INTENDED OWNER/BUILDER 1S NOT PERMITTED. <br />ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. <br />SITE WORK <br />1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN <br />WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND <br />WATERPROOFING. <br />2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS <br />BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. <br />3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO <br />ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE <br />TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. <br />4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER <br />APPLICABLE CODE. <br />MECHANICAL <br />1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN <br />ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. <br />2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL <br />CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES. <br />PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE <br />WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH <br />THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE <br />GARAGE FLOOR. <br />THERMAL AND MOISTURE <br />1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE <br />OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON <br />PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. <br />2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION <br />WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE <br />INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) <br />3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER <br />MANUFACTURER'S INSTRUCTIONS. <br />4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES <br />AND OVER FOOTINGS. <br />FINISHES <br />GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD. <br />GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/8" GYPSUM WALL BOARD. <br />WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM <br />WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND <br />COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS <br />SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS <br />SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- <br />PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE <br />INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, <br />BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. <br />ELECTRICAL <br />SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN <br />ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN <br />THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. <br />AREA CALCULATIONS <br />HEATED AREAS <br />SQUARE FOOTAGE <br />2ND FLOOR <br />1811 <br />MAIN FLOOR <br />1215 <br />TOTAL <br />3026 <br />NON -HEATED AREAS <br />SQUARE FOOTAGE <br />GARAGE <br />640 <br />BACK COVERED PATIO <br />160 <br />COVERED FRONT PORCH <br />58 <br />EET NO. DESCRIPTION <br />Al <br />COVER SHEET, INDEX, GENERAL NOTES <br />A2 <br />ENERGY CALCULATIONS <br />A3 <br />ELEVATIONS <br />A4 <br />ELEVATIONS <br />A5 <br />MAIN FLOOR PLAN <br />A6 <br />2ND FLOOR PLAN <br />A7 <br />BUIDLING CROSS SECTION & MISC. DETAILS <br />S1 <br />STRUCTURAL NOTES/STRUCTRUAL DETAILS <br />S2 <br />STRUCTURAL DETAILS <br />S3 <br />SHEARWALL & HOLDOWN LOCATIONS <br />S4 <br />FOUNDATION PLAN <br />S5 <br />MAIN FLOOR FRAMING <br />S6 <br />2ND FLOOR FRAMING <br />S7 <br />ROOF PLAN <br />SYMBOL LEGEND <br />HAYWARD HOMES <br />0 '1 <br />Additional Permits Are Required <br />For This Project To Include: <br />Plumbing [-1 Sprinkler <br />Mechanical [ Fire Alarm <br />Electrical <br />THOSE DOCUMENTS i <br />APPROVED <br />ryt OR. THE ISSUANCE OF <br />WORKS,PUBLIC , <br />SUPPRESSION, ELECTRICAL OR <br />r'LUMBING PERMITS. <br />APPROVED <br />FIRESTOPPING <br />CARBON MONOXIDE DETECTOR <br />pfflCe of Community, Planning &Economic Deveiopn►er►t <br />INTERCONNECTED 110v w/ BATTERY BACKUP <br />PLANNING DEPARTMENT <br />FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND <br />C.O. <br />CAN BE COMBINED w/ S.D. <br />HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND <br />SMOKE DETECTOR <br />E��--- DATE. <br />THE ROOF SPACE, FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING <br />LOCATIONS: <br />S.D. <br />INTERCONNECTED 110v w/ BATTERY BACKUP <br />n <br />�UNQ,y `gQ���reN <br />1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" <br />O <br />EXHAUST FAN (VENT TO OUTSIDE) <br />HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. <br />2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT <br />SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. <br />O <br />KEYNOTE <br />3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL <br />CAVITIES IN LINE WITH STRINGERS, <br />4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH <br />101 <br />DOOR SCHEDULE SYMBOL <br />NON-COMBUSTABLE MATERIALS. <br />1i <br />WINDOW SCHEDULE SYMBOL <br />MISCELLANEOUS <br />A <br />E DESCRIPTION IN <br />TITLE BLOCK <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. <br />SIM <br />DETAIL SYMBOL <br />2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND <br />l <br />ELECTRICAL WORK. <br />101 <br />SIMILAR DETAIL <br />3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND <br />DETAIL NO. <br />INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND <br />SHEET N0. <br />OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE <br />SIM <br />ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE <br />1 <br />BUILDING CROSS SECTION <br />BEDROOMS. (R315) <br />10 <br />4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE <br />DETAIL NO. <br />BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. <br />SHEET NO. <br />5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO <br />MAKE THEM WATERPROOF. ROOF FLASHING PER R903. <br />Room name <br />—ROOM NAME <br />& GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) <br />7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER <br />CANNOT PASS THROUGH. <br />8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM <br />NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF <br />44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). <br />t KtIOW what's ti@1®111►• STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO <br />® call before you dig. LOCATE ALL UNDERGROUND UTILITIES. <br />Date: <br />10/23/2020 <br />osed Use: <br />NEW SINGLE FAMILY <br />ription: <br />CONSTRUCT NEW SFR <br />WITH GARAGE <br />Date: `f <br />awed By: <br />)ffice Set <br />Job Site Set <br />Fire/Planning Set <br />M CO o <br />Z <br />oO N C <br />W <br />V <br />t1r: <br />o °�' <br />UJ <br />M <br />_J <br />o <br />W <br />a <br />F— <br />_ <br />Z y d a L m_ V@ "O C. C O O <br />oZ JcoCjm=a mu°�,oaci`-0o-C <br />O N� <br />(�OON2 o2 f0O'ol0.s.N� <br />� - tTJ <br />OUJ S2CUo�No�c3.cmo� <br />UUJ <br />JJ� <br />H ZSlV <br />LU <br />LU <br />00 <br />• <br />LU <br />too) <br />UJ <br />LU <br />0 <br />__0 <br />PROJECT NO. <br />200202 <br />DESIGNED BY <br />TL <br />DRAWN BY <br />TL & RM <br />CHECKED BY <br />TL <br />SHEET NO. <br />Al <br />PRINT DATE 9/23/2020 8:15:42 AM <br />