Permit#: C2010-W2
<br />Site Address: 3618 SHORE AVE
<br />Owner: CASCADE GENERAL CONTRACTING INC
<br />Tenant: [TenNamel
<br />GENERAL NOTES
<br />GENERAL REQUIREMENTS
<br />ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN),
<br />INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE,
<br />INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE
<br />AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE.
<br />THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO
<br />CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND
<br />WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE
<br />RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER
<br />REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE.
<br />THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR
<br />CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR
<br />DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL
<br />BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND
<br />WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING
<br />COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE
<br />INTENDED OWNER/BUILDER 1S NOT PERMITTED.
<br />ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE.
<br />SITE WORK
<br />1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN
<br />WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND
<br />WATERPROOFING.
<br />2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS
<br />BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES.
<br />3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO
<br />ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE
<br />TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES.
<br />4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER
<br />APPLICABLE CODE.
<br />MECHANICAL
<br />1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN
<br />ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES.
<br />2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL
<br />CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES.
<br />PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE
<br />WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH
<br />THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE
<br />GARAGE FLOOR.
<br />THERMAL AND MOISTURE
<br />1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE
<br />OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON
<br />PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET.
<br />2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION
<br />WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE
<br />INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1)
<br />3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER
<br />MANUFACTURER'S INSTRUCTIONS.
<br />4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES
<br />AND OVER FOOTINGS.
<br />FINISHES
<br />GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8" TYPE "X" GYPSUM WALL BOARD.
<br />GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/8" GYPSUM WALL BOARD.
<br />WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM
<br />WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND
<br />COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS
<br />SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS
<br />SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER-
<br />PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE
<br />INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS,
<br />BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES.
<br />ELECTRICAL
<br />SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN
<br />ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN
<br />THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY.
<br />AREA CALCULATIONS
<br />HEATED AREAS
<br />SQUARE FOOTAGE
<br />2ND FLOOR
<br />1811
<br />MAIN FLOOR
<br />1215
<br />TOTAL
<br />3026
<br />NON -HEATED AREAS
<br />SQUARE FOOTAGE
<br />GARAGE
<br />640
<br />BACK COVERED PATIO
<br />160
<br />COVERED FRONT PORCH
<br />58
<br />EET NO. DESCRIPTION
<br />Al
<br />COVER SHEET, INDEX, GENERAL NOTES
<br />A2
<br />ENERGY CALCULATIONS
<br />A3
<br />ELEVATIONS
<br />A4
<br />ELEVATIONS
<br />A5
<br />MAIN FLOOR PLAN
<br />A6
<br />2ND FLOOR PLAN
<br />A7
<br />BUIDLING CROSS SECTION & MISC. DETAILS
<br />S1
<br />STRUCTURAL NOTES/STRUCTRUAL DETAILS
<br />S2
<br />STRUCTURAL DETAILS
<br />S3
<br />SHEARWALL & HOLDOWN LOCATIONS
<br />S4
<br />FOUNDATION PLAN
<br />S5
<br />MAIN FLOOR FRAMING
<br />S6
<br />2ND FLOOR FRAMING
<br />S7
<br />ROOF PLAN
<br />SYMBOL LEGEND
<br />HAYWARD HOMES
<br />0 '1
<br />Additional Permits Are Required
<br />For This Project To Include:
<br />Plumbing [-1 Sprinkler
<br />Mechanical [ Fire Alarm
<br />Electrical
<br />THOSE DOCUMENTS i
<br />APPROVED
<br />ryt OR. THE ISSUANCE OF
<br />WORKS,PUBLIC ,
<br />SUPPRESSION, ELECTRICAL OR
<br />r'LUMBING PERMITS.
<br />APPROVED
<br />FIRESTOPPING
<br />CARBON MONOXIDE DETECTOR
<br />pfflCe of Community, Planning &Economic Deveiopn►er►t
<br />INTERCONNECTED 110v w/ BATTERY BACKUP
<br />PLANNING DEPARTMENT
<br />FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND
<br />C.O.
<br />CAN BE COMBINED w/ S.D.
<br />HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND
<br />SMOKE DETECTOR
<br />E��--- DATE.
<br />THE ROOF SPACE, FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING
<br />LOCATIONS:
<br />S.D.
<br />INTERCONNECTED 110v w/ BATTERY BACKUP
<br />n
<br />�UNQ,y `gQ���reN
<br />1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0"
<br />O
<br />EXHAUST FAN (VENT TO OUTSIDE)
<br />HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL.
<br />2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT
<br />SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC.
<br />O
<br />KEYNOTE
<br />3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL
<br />CAVITIES IN LINE WITH STRINGERS,
<br />4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH
<br />101
<br />DOOR SCHEDULE SYMBOL
<br />NON-COMBUSTABLE MATERIALS.
<br />1i
<br />WINDOW SCHEDULE SYMBOL
<br />MISCELLANEOUS
<br />A
<br />E DESCRIPTION IN
<br />TITLE BLOCK
<br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING.
<br />SIM
<br />DETAIL SYMBOL
<br />2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND
<br />l
<br />ELECTRICAL WORK.
<br />101
<br />SIMILAR DETAIL
<br />3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND
<br />DETAIL NO.
<br />INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND
<br />SHEET N0.
<br />OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE
<br />SIM
<br />ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE
<br />1
<br />BUILDING CROSS SECTION
<br />BEDROOMS. (R315)
<br />10
<br />4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE
<br />DETAIL NO.
<br />BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS.
<br />SHEET NO.
<br />5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO
<br />MAKE THEM WATERPROOF. ROOF FLASHING PER R903.
<br />Room name
<br />—ROOM NAME
<br />& GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.)
<br />7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER
<br />CANNOT PASS THROUGH.
<br />8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM
<br />NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF
<br />44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1).
<br />t KtIOW what's ti@1®111►• STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO
<br />® call before you dig. LOCATE ALL UNDERGROUND UTILITIES.
<br />Date:
<br />10/23/2020
<br />osed Use:
<br />NEW SINGLE FAMILY
<br />ription:
<br />CONSTRUCT NEW SFR
<br />WITH GARAGE
<br />Date: `f
<br />awed By:
<br />)ffice Set
<br />Job Site Set
<br />Fire/Planning Set
<br />M CO o
<br />Z
<br />oO N C
<br />W
<br />V
<br />t1r:
<br />o °�'
<br />UJ
<br />M
<br />_J
<br />o
<br />W
<br />a
<br />F—
<br />_
<br />Z y d a L m_ V@ "O C. C O O
<br />oZ JcoCjm=a mu°�,oaci`-0o-C
<br />O N�
<br />(�OON2 o2 f0O'ol0.s.N�
<br />� - tTJ
<br />OUJ S2CUo�No�c3.cmo�
<br />UUJ
<br />JJ�
<br />H ZSlV
<br />LU
<br />LU
<br />00
<br />•
<br />LU
<br />too)
<br />UJ
<br />LU
<br />0
<br />__0
<br />PROJECT NO.
<br />200202
<br />DESIGNED BY
<br />TL
<br />DRAWN BY
<br />TL & RM
<br />CHECKED BY
<br />TL
<br />SHEET NO.
<br />Al
<br />PRINT DATE 9/23/2020 8:15:42 AM