Laserfiche WebLink
Permit#: FA2502-004 <br /> Site Address: 916 Pacific Ave <br /> Applicant: Larissa Thomson co nve rg j nta <br /> • Application Date:02/05/2025 <br /> convergInt Description Providence Pacific-Level2 Behavioral Health <br /> Review Date: 02/O6/2025 <br /> 450 Shattuck Avenue South,Renton,Washington 98057 <br /> Phone:425-272-2250 Fax:425-251-0949 <br /> EV`TT This document and the inf-b.n/depicb.ns mnWinedlshown <br /> is the exclusive property of con-mint Technologies LLC and shall <br /> Everett Fire Dept.Permit Review ba handled as propnetary and wnfld.nti.1 information and must be <br /> Status'Approved retuRI upon request.This dowm-It cannot be repraduced by any <br /> n,Nna without the wdden authorization of Convergint Technologies LLC. <br /> PROVIDENCE PACIFIC Reviewed KBrown <br /> 02/06/2025 4:04:38 <br /> PM <br /> LEVEL 2 BEHAVIORAL HEALTH <br /> , <br /> 916 PACIFIC AVE, EVERETT, WA 98201 <br /> SYMBOL LEGEND SCOPE OF WORK WIRE LEGEND MOUNTING HEIGHTS <br /> SYM DESCRIPTION MODEL# MANUFACTURER BACK BOX THIS SCOPE OF WORK INCLUDES: ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVANT <br /> EXISTING EST3 ANALOG ADDRESSABLE FIRE ALARM SYSTEM WITH VOICE EVACUATION TO REMAIN. NATIONAL AND LOCAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. A/C SUPPLY DIFFUSER <br /> SPEAKER/STROBE-CEILING MOUNT 4906-9154 SIMPLEX 4"SQUARE RELOCATE AND ADD NEW SMOKE DETECTORS TO SUPPORT NEW ROOM LAYOUT. <br /> REMOVE AND RELOCATED EXISTING AND ADD NEW NOTIFICATION DEVICES TO SUPPORT NEW WIRING INSTALLATION NOTES: CEILING MOUNTED FLUORESCENT LIGHT <br /> c ROOM LAYOUT. •LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND DESCRIPTION. SMOKEIHEAT <br /> SPEAKER-CEILING MOUNT 4902-9721 SIMPLEX 4"SQUARE EXISTING POWER SUPPLY WILL BE USED TO SUPPORT ADDED STROBES. 'LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. DETECTOR TYP. 3'(MIN) <br /> EXISTING EST3 SPEAKER AMPLIFIER WILL BE USED TO SUPPORT ADDED SPEAKERS. 'LABEL ALL NETWORK,ANNUNCIATOR AND I/O CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER NOTE:DIMENSIONS SHOWN <br /> ARE To THE CLOSEST <br /> STROBE-WALL MOUNT 4904-9168 SIMPLEX 4"SQUARE TAG AND DESCRIPTION. CEILING EDGE OF THE DErE.ToR <br /> •VERIFY WITH OWNER AND GENERAL CONTRACTOR THAT OPEN CABLE IS ALLOWED ON SPECIFIC <br /> STANDARD ADDRESSABLE SMOKE DESIGN CRITERIA APPLICABLE STANDARDS AND GUIDANCE: SITE.(FPL,FPLP,RISER,OR 2 HOUR RATED) <br /> Os SIG-OSD EST 4"OCTAGON BOX,1-1/2"DEEP <br /> SIGA-SB4-STANDARD BASE NFPA 72,2019 EDITION 'WHERE REQUIRED,OUR DRAWINGS WILL NOTE WIRE OR PATHWAY REQUIRING SURVIVABILITY. - <br /> 2021 WASHINGTON STATE BUILDING CODE SUBSTITUTE THE RELEVANT CABLE WITH AN EQUIVALENT CABLE COMPATIBLE WITH THE MEANS OF 'I 3' i2• <br /> 2021 WASHINGTON STATE MECHANICAL CODE SURVIVABILITY.THIS OFTEN INCLUDES;CI-C OR Cl CABLE(CIRCUIT INTEGRITY),CONCRETE AUDIONISUAL&VISUAL MAX <br /> 2023 NATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS ENCASEMENT OR OTHER MEANS AS APPROVED BY THE AHJ.REFER TO NFPA 72 FOR FURTHER ONLY DEVICES <br /> 2021 WASHINGTON STATE FIRE CODE INFORMATION. 5 <br /> FIRE ALARM REMOTE MANUAL PULL <br /> NON PLENUM: SINGLE COND.: PLENUM RATED: FIRE ALARM ANNUNCIATOR STATION <br /> OCCUPANCY/USE CLASSIFICATIONS: CIRCUIT DESCRIPTION (FPLR,FPL) (THHN,TFFN) (FPLP) CONTROL PANEL <br /> 1-2-INSTITUTIONAL <br /> A ZONE/INPUT CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/F7] 80"MIN.TO BOTTOM <br /> DOCUMENTATION AVAILABLE TO CONVERGINT TECHNOLOGIES OF LENS <br /> C IN CIRCUIT BELDEN5120UL (2)#14AWG BELDEN 612OUL OR �+ <br /> ARCHITECTURAL DRAWINGS DATED 08-22-2024 p <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FF] 96'MAX.TO TOPT w <br /> ELECTRICAL DRAWINGS DATED 08-22-2024 O <br /> MECHANICAL DRAWINGS DATED 08-22-2024 D MASS.NOTIFICATION NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL OF LENS 72'AFF 60"AFF <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] 48"MAX(ADA) LL <br /> 42"MIN/54"MAX(NFPA) <br /> E DOOR HOLDER/CONTROL CIRCUIT BELDEN5120UL (2)#14AWG BELDEN 6120UL <br /> CONTACT INFORMATION _2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> FINISHED FLOOR <br /> F FAN/HVAC SHUTDOWN BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> PROJECT MANAGER FIRE ALARM DESIGNER 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] 'DEVICES SHOWN DEPICT DEVICE TYPES ONLY. <br /> CARISS_THOMSON TA5_ _HARRIS G FUTURE ADANAC BELDEN5120UL (2)#14AWG BELDEN 6120UL <br /> 425-757-3295 425-521-3607 CIRCUIT2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FTJ <br /> CARISSA.THOMSON@CONVERGINT.COM TAYLOR.HARRIS@CONVERGINT.COM <br /> SALES REPRESENTATIVE H PHONE CIRCUIT BELDEN 5220FL N/A BELDEN 6220FL ` <br /> KEVIN CURRIE 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.85D][77pF/FT] <br /> 206-941-4692 0 _ <br /> KEVIN.CURREY@CONVERGINT.COM J 2CONDSPEAKERCIRCUIT BELDEN (2)#16 AWG BELDEN 6220UL w _ <br /> E <br /> 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] - <br /> L ELEVATOR CONTROL BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> GENERAL NOTES 2COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FF] <br /> M AUDIO RISER BELDEN 5220FL N/A BELDEN 6220FL <br /> 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> THE FOLLOWING NOTES ARE INTENDED TO BE GENERAL IN NATURE AND ARE NOT SPECIFIC TO EACH N NETWORK COMMUNICATIONS BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> PROJECT.THESE NOTES ARE TO BE FOLLOWED WHERE APPLICABLE TO INDIVIDUAL PROJECTS AND 2 COND.16 AWG [3.850][24pF/FT] 13.850][37pF/F7] <br /> SHOULD NOT BE TAKEN AS SCOPE OR DIRECTION WHERE THEY CONFLICT WITH INFORMATION FOUND <br /> ELSEWHERE IN THIS DRAWING SET. P 24VDC AUX.POWER BELDEN 5120UL (2)#14 AWG BELDEN 6120UL ".,,�,.°.. <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] _ <br /> 1. ALL WIRE AND CONDUIT SHALL BE INSTALLED IN ACCORDANCE WITH PLANS AND Q VESDA NET BELDEN 9841 _ <br /> SPECIFICATIONS AND SHALL MEET ALL APPLICABLE CODES. N/A BELDEN 89841 dQ <br /> 2 COND.22 AWG [240][12.8pF/FT] [240][12pF/FT] �IN <br /> 2. ALL WIRE AND CABLE SHALL BE RATED FOR FIRE ALARM USE PER THE LATEST REVISIONS OF R REMOTE LED CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL THE NATIONAL ELECTRICAL CODE(NEC)SECTION 760.THIS IS A POWER LIMITED FIRE ALARM 2 COND.16 AWG [3.850][24pF/FT] [3.85D][37pF/FT] <br /> SYSTEM.ALL CABLE MUST BE MARKED FPL,FPLP,FPLR OR Cl.FURTHER NEC,REQUIRES ALL t, <br /> WIRE BE RATED FOR THE ENVIRONMENT FOR WHICH IT IS INSTALLED.ANY REFERENCES TO S ADDRESSABLE DATA SLC LOOP BELDEN 5320UL (2)#18 AWG BELDEN 632OUL 3ma s, nz^o <br /> WIRE DESIGNATIONS ASSUME ELECTRICAL CONTRACTOR WILL SUBSTITUTE APPROPRIATE 2 COND.18 AWG [6.40][29pF/FT] [6.40][31pF/FT] <br /> WIRE TO MEET CODE. w+m"Arc <br /> T1 ANALOG TWO-WAY COMM.CABLE N/A N/A RATH RP66010001 3 <br /> ,00�eea«r�een Meama came <br /> 3. ALL CONDUCTORS SHALL TEST FREE OF GROUNDS AND SHORTS BEFORE MAKING ANY 2 COND.18 AWG [2-HOUR CIC] 3 - ai°e°mws%P°im fo,wo,ne" a' <br /> CONNECTION TO THE FIRE ALARM CONTROL PANEL. T2 ANALOG WAY COMM.CABLE RATH 66120 N/A <br /> 18 A <br /> 2 COND.18 A N/A ` = DESIGNER OF RECORD <br /> 4. TO RETAIN WARRANTY,THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE AWG [2-HOUR] vas <br /> SUPERVISION OF A QUALIFIED MANUFACTURERS TECHNICIAN. TP ANALOG TWO-WAY POWER CABLE N/A RATH R66010001 33rd slo aim s, LOR HAR <br /> 2 COND.18 AWG N/A [2-HOUR CIC] v"re,c, L 5 PiREA TA IARN SlsTENs <br /> yi Ris <br /> 5. THE INSTALLING ELECTRICAL CONTRACTOR SHALL COORDINATE ALL FIELD CHANGES WITH THE - a <br /> FIRE ALARM CONTRACTOR.THIS INCLUDES CHANGES IN DEVICES,WIRE,CONDUIT RUNS AND U SUPPRESSION RELEASING CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> OPERATION OF THE SYSTEM.FIRE ALARM CONTRACTOR SHALL NOT BE HELD RESPONSIBLE 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/Fl] N1i°w E csanPicAnoettsysa <br /> EXPIRE DATE'.,gn1-2a2] <br /> FOR UNDOCUMENTED CHANGES OR THE RESULTS OF THOSE CHANGES. W SINGLE MODE FIBER NETWORK BUDGET SMXL02/SMXH12:15/25 dBm x FORVERiFICATON.PLEA SIT.NiCETORGrvERiFY <br /> 6. FIRE ALARM NOTIFICATION DEVICES SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL 8.3p SM CONNECTOR:DUPLEX SC <br /> HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE THE AVERAGE AMBIENT SOUND X MULTIMODE FIBER NETWORK BUDGET MMXVR:10 dBm <br /> LEVEL OR 5db ABOVE THE MAXIMUM SOUND LEVEL,MEASURED AT 5'0"ABOVE THE FINISHED 50/125P'62.5/125p OR 100/140p MM CONNECTOR:ST - <br /> FLOOR. VICINITY MAP <br /> Y TWO-WAY COMMUNICATIONS BELDEN 1583A N/A BELDEN 1585A <br /> 7. MAIN BUILDING FIRE ALARM&SUPPRESSION SYSTEMS SHALL BE CLASS"B"WIRING. I CAT5E-(4)PAIR 22 AWG ,N <br /> PRE-ACTION&DELUGE ALARM SYSTEMS SHALL BE CLASS"A"WIRING.CLASS"A"APPLICATIONS Z FIRE/SMOKE DAMPER INTERFACE BELDEN 5120UL (2)#14 AWG BELDEN 6120UL conve rg j nt'SHALL MAINTAIN A MINIMUM SEPARATION OF 48 INCHES HORIZONTALLY&12 INCHES 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> VERTICALLY BETWEEN OUTGOING AND RETURN CIRCUITS. <br /> NOTE:ALL LISTED RESISTANCE AND CAPACITANCE ARE CONDUCTOR TO CONDUCTOR.ALL <br /> 8. ALL PULL STATIONS AND NOTIFICATION DEVICES SHALL BE MOUNTED AT HEIGHTSSPECIFIED RESISTANCE VALUES ARE PER 1000 FEET. ABBREVIATIONS <br /> PER NFPA 72 AND ADA REQUIREMENTS. <br /> 9. ALL DETECTOR SPACING SHALL BE PER NFPA 72&LOCAL CODES. AC-ABOVE CEILING FSD-FIRE SMOKE DAMPER(THIRD PARTY) <br /> SHEET LIST TABLE AFF-ABOVE FINISHED FLOOR HVAC-HEATING,VENTILATION,AND AIR <br /> 10. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH-IN LOCATIONS WITH OTHER A -AMERICAN DISABILITIES ACT CONDITIONING(THIRD PARTY) <br /> TRADES. SHEET NUMBER SHEET TITLE AHJ-AUTHORITY HAVING JURISDICTION LA-LOW AIR(THIRD PARTY) <br /> FA-0-1 COVER SHEET AHU-AIR HANDLING UNIT(THIRD PARTY) N/A-NOTAPPLICABLE <br /> FA-0-2 NOTES ASD-ASPIRATION SMOKE DETECTION NAC-NOTIFICATION APPLIANCE CIRCUIT <br /> 11. ALL FIRE ALARM DEVICES SHALL BE SECURELY FASTENED TO WALLS OR CEILINGS. FA-1-2.2 LEVEL 2 NORTH FA-2-1 TYPICAL RISER CD-CANDELA(EX.15CD) NFPA-NATIONAL FIRE PROTECTION ASSOCIATION <br /> 12. SMOKE DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY AIR REGISTER OR F -1 D I <br /> DIFFUSER. DH-DOOR HOLDER(THIRD PARTY UNO) NTS-NOT TO SCALE CIS-COMMON INTELLIGIBILITY SCALE NIC-NOT IN CONTRACT <br /> EF-EXHAUST FAN(THIRD PARK) PS-POWER SUPPLY <br /> 13. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY AIR REGISTER OR ELEV-ELEVATOR(THIRD PARTY) RTU-ROOF TOP UNIT(THIRD PARTY) <br /> EOL-END OF LINE SLC-SIGNALING LINE CIRCUIT <br /> DIFFUSER. EPF-ELEVATOR PRESSURIZATION FAN(THIRD PARTY) SPF-STAIR PRESSURIZATION FAN(THIRD PARTY) <br /> 14. PER NFPA 72,CHAPTER 17;SMOKE DETECTORS INSTALLED PRIOR TO FINAL CLEAN MUST BE FA-FIRE ALARM STI-SPEECH TRANSMISSION INDEX <br /> CLEANED AND VERIFIED TO BE OPERATING IN ACCORDANCE WITH THE LISTED SENSITIVITY,OR FAA-FIRE ALARM ANNUNCIATOR NP-TYPICAL <br /> THEY SHALL BE REPLACED PRIOR TO THE FINAL COMMISSIONING OF THE SYSTEM. FACP-FIRE ALARM CONTROL PANEL UNO-UNLESS NOTED OTHERWISE <br /> CONVERGINT BEARS NO RESPONSIBILITY FOR LABOR OR MATERIAL ASSOCIATED WITH FACU-FIRE ALARM CONTROL UNIT VAV-VARIABLE AIR VOLUME(THIRD PARTY) <br /> CLEANING,SENSITIVITY TESTING OR REPLACEMENT OF SMOKE DETECTORS INSTALLED PRIOR FA7--FIRE ALARM TERMINAL CABINET VFD-VARIABLE FREQUENCY DRIVE(THIRD PARK) <br /> FBO-FURNISHED IT OTHERS W/-WITH <br /> TO FINAL CLEANING. FCU-FAN COIL UNIT(THIRD PARK) W-WATT(EX.1/2W) <br /> 15. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY HEAT GENERATING FFT-FIREFIGHTER'S TELEPHONE WP-WEATHERPROOF <br /> DEVICE(FUSES,BOILERS,WATER HEATERS,ETC.)IN MECHANICAL ROOMS. FM-FACTORY MUTUAL XP-EXPLOSION PROOF <br /> JON-DESCRIPTION DATE <br /> 16. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 18"TO ANY PART OF ANY LIGHT FLOOR PLAN KEY TH <br /> FIXTURE. I ENGINEERING REVISIONS <br /> DEVICE ADDRESS KEY DETAIL BUBBLE KEY <br /> 17. HEAT DETECTORS SHALL BE MOUNTED WITHIN 24"OF A SPRINKLER HEAD WHEN USED FOR <br /> ELEVATOR SHUNT TRIP IN ELEVATOR MACHINE ROOMS&SHAFTS. L DETAIL NUMBER <br /> FIRE ALARM PANE # <br /> 18. INITIATING AND SIGNALING CIRCUITS MAY BE RUN IN SAME CONDUIT. 0 DEVICE ADDRESS 4DETAIL <br /> ////19. ALL CONDUCTORS SHALL BE LABELED BY ZONE OR SLC LOOP NUMBER. z-x-xxzz-x LOCATION I- SAME SHEET) <br /> p 20. THESE DRAWINGS ARE INTENDED TO SHOW PROJECT SPECIFIC PANELS,DEVICES AND WIRING DATACARD, _ISOLATED <br /> I S L REDBRANCH <br /> U DEPICTED DIAGRAMMATICALLY.WIRING SHOWN IS NOT INTENDED TO DEPICT RACEWAY OR LOGICAL ADDRESS (A ) TAnoR H. <br /> 0 PATHWAY LOCATIONS.DEVICE AND PANEL LOCATIONS SHALL BE COORDINATED BY INSTALLING PROJECT DESIGNER: T-OR H. <br /> JCONTRACTOR AS PART OF THE CONSTRUCTION PROCESS. <br /> Q NOTIFICATION DEVICE CIRCUIT KEY DRAWING SHEET INDEX KEY usm ja eea <br /> U 21. AS THE FIRE ALARM VENDOR UTILIZED FOR THIS BUILDING,NFPA 72 REQUIRES WE KEEP owN DATE '-,e-za: <br /> U ACCURATE RECORD DRAWING INFORMATION.AS SUCH,IT IS NECESSARY THAT WE DEPICT SPCEAKER CIRCUIT NUMBER FIRE ALARM �LEVEIJFLOOR/ARFA <br /> Q EXISTING DEVICES AND WIRING IN ADDITION TO THOSE COMPONENTS ASSOCIATED WITH YOUR IRCUIT <br /> t/7 SCOPEW HERE APPLICABLE.UNLESS OTHERWISE NOTED,IT IS ASSUMED EXISTING CIRCUIT NUMBER Sp FA-X.XX PROVIDENCE PACIFIC <br /> POWER SUPPLY XW <br /> COMPONENTS WILL REMAIN UN-DISTURBED BY YOUR SCOPE OF WORK.TO AID IN IDENTIFYING SUFFIX H LEVEL 2 BEHAVIORAL HEALTH <br /> NEW VS.EXISTING,WE WILL TURN EXISTING COMPONENTS TO A LIGHTER SHADE.REMOVAL OF O=COVER SHEET 916 PACIFIC AVE <br /> v -x <br /> THE EXISTING DEVICES AND WIRING MAY OTHERWISE IMPACT THE CONTEXT OF THE /Nxx-x-x 1=FLOOR PLANS <br /> x COMPLETE,CODE REQUIRED FIRE ALARM SYSTEM,THEREFORE THEY CANNOT BE OMITTED `\ 2-RISER DIAGRAMS EVERETT,WA 98201 <br /> FROM OUR DRAWING PACKAGE. `LOGICAL DEVICE NUMBER 3=FIRE PANEL DETAILS <br /> O 4=DEVICE DETAILS <br /> M <br /> 5=CALCULATIONS <br /> z6=2-WAVCOMMUNICATION COVER SHEET <br /> FIRE ALARM SYSTEM <br /> () <br /> Z <br /> wlNc. <br /> o FA-0-1 <br /> tL <br />