My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-27 Plans 2025-09-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-27
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-27 Plans 2025-09-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2025 3:40:05 PM
Creation date
9/9/2025 3:40:00 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-27
Permit
FA2408-006
Year
2024
Notes
Fire Alarm T.I. Building 40-27
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADD. BASE EQUIPMENT LEGEND / BILL OF MATERIAL <br /> PROJ. PROJ. <br /> SYMBOL CITY CITY ITEM DESCRIPTION PART NUMBER MANUFACTURER <br /> FACP EXIST. 1 FIRE ALARM CONTROL PANEL XLS SIEMENS <br /> 1 2 ZONE INDICATING CARD ZIC-4A SIEMENS <br /> BOENG COMMERDA ARP A N E GROUP ❑ 1 3 ADDRESSABLE RELAY MODULE SIEMENS <br /> M4 1 4 QUAD INTERFACE MODULE 41NPUT/4OUTPUT FDC10422 SIEMENS <br /> H 5623 3 5 HEAT DETECTOR, 135FT, CONVENTIONAL (SHUNT TRIP) 5623 SYSTEM SENSOR <br /> S 4 6 ADDRESSABLE SMOKE DETECTOR OP921 SIEMENS <br /> Permit d 3003 W-Cas 4 0 - 2 7 TENANT IMPROVEMENT 4 7 SMOKE DETECTOR BASE MB-11 SIEMENS <br /> Site Address: 3003 W Casino Rd BLDG 40-27 �_r-y� <br /> Applicant: Seatronics Inc HOD 2 8 6" ELECTRIC BELL M624-6 SIEMENS <br /> Application Date:08/19/2024 TS 9 SPRINKLER VALVE SWITCH (BY OTHERS) <br /> Description: Fire Alarm T.I.Building 40-27 <br /> Review Date: 08/21/2024 B 0 E I N G EVERETT F A CU T Y <br /> EVERETT ere <br /> .... 3003 WEST CAST N 0 ROAD <br /> Everett Fire Dept.Permit Review Status:Approved EVERETT, W A S H I N G T O N 98203 <br /> Reviewed By:KBrown <br /> 08/21/2024 12:19:23 <br /> PM <br /> FIRE ALARM GENERAL ELECTRICAL NOTES SYSTEM SEQUENCE OF OPERATION: <br /> 1. THE INSTALLATION OF THE SYSTEM(S) SHALL MEET THE REQUIREMENTS OF THE <br /> SPECIFICATION, NFPA 70 (NEC), NFPA 72, ALL APPLICABLE LOCAL CODES, AND 1. ALARM CONDITIONS - ELEVATOR LOBBIES: <br /> THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. 1.1 ACTIVATION OF SMOKE DETECTOR ON THE FLOOR 2 LOBBY SHALL <br /> 2. FASTEN EQUIPMENT TO STRUCTURAL MEMBERS OF BUILDING OR METAL SUPPORTS CAUSE THE FOLLOWING TO OCCUR: <br /> ATTACHED TO STRUCTURE, OR TO CONCRETE SURFACES. A. ILLUMINATE THE RED "ALARM" INDICATOR ON THE FAP. <br /> B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING <br /> 3. ALL PANELS SHALL BE MOUNTED WITH SUFFICIENT CLEARANCE FOR OBSERVATION, LOCATION INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. <br /> TESTING AND MAINTENANCE. ALL JUNCTION BOXES & COVERS SHALL BE PAINTED C. ACTIVATE ALARM BELL UNIT(S) IN ELEVATOR LOBBIES. <br /> RED. D. TRANSMIT AN "ALARM"SIGNAL TO THE REMOTE MONITORING STATION. <br /> 4. ALL WIRE SHALL BE SUPPLIED AND INSTALLED IN COMPLIANCE WITH THE E. RECALL ELEVATOR TO PRIMARY FLOOR (FLOOR 1). <br /> REQUIREMENTS OF NFPA 70, ARTICLE 760 AND AS NOTED ON THE DRAWINGS. F. ACTIVATE HVAC SHUT DOWN RELAY. <br /> 5. A CONSISTENT COLOR CODE FOR FIRE ALARM SYSTEM CONDUCTORS SHALL BE 1.2 ACTIVATION OF SMOKE DETECTOR ON THE 1ST FLOOR ELEVATOR LOBBY <br /> USED THROUGHOUT THE INSTALLATION. SHALL CAUSE THE FOLLOWING TO OCCUR: <br /> 6. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION SHALL BE A. ILLUMINATE THE RED "ALARM" INDICATOR ON THE FAR. <br /> DETERMINED IN THE FIELD BUT SHALL GENERALLY CONFORM TO TO THE LAYOUT B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING <br /> SHOWN. INSTALLER SHALL MAINTAIN A SET OF DRAWINGS WHICH SHOW ALL LOCATION INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. <br /> C. ACTIVATE ALARM BELL UNIT(S) IN ELEVATOR LOBBIES. <br /> CHANGES IN ROUTING OF CONDUIT AND/OR CABLING. A COMPLETE SET OF THESE <br /> D. TRANSMIT AN "ALARM"SIGNAL R THE REMOTE MONITORING STATION. <br /> "MARKED UP" DRAWINGS SHALL BE PROVIDED TO SEATRONICS UPON COMPLETION E. RECALL ELEVATOR TO THE ALTERNATE FLOOR (FLOOR 2). <br /> OF THE INSTALLATION. <br /> F. ACTIVATE HVAC SHUT DOWN RELAY. <br /> 7. ALL NAC DEVICES SHALL BE INSTALLED IN THE SEQUENCE SHOWN ON THE <br /> DRAWINGS. <br /> 2. ALARM CONDITIONS - MACHINE ROOM & HOISTWAY <br /> 8. ALL FIELD WIRING SHALL BE TESTED FOR SHORTS, OPENS AND GROUNDS PRIOR <br /> TO CONNECTION TO THE CONTROL PANEL AND BEFORE DETECTORS ARE PLUGGED 2.1 ACTIVATION OF A SMOKE DETECTOR IN THE ELEVATOR MACHINE ROOM <br /> INTO THE BASES. OR TOP OF HOISTWAY SHALL CAUSE THE FOLLOWING TO OCCUR: <br /> A. ILLUMINATE THE RED "ALARM" INDICATOR ON THE ELEVATOR FAR. <br /> 9. SHIELD DRAIN WIRE: UNLESS OTHERWISE NOTED, CABLE SHIELD DRAIN WIRE SHALL B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING <br /> BE GROUNDED ONLY AT THE THE PANEL/MODULE OF CIRCUIT ORIGIN. AT ALL LOCATION INFORMATION FOR THE DEVICE THAT WAS ACTIVATED, <br /> OTHER LOCATIONS DRAIN WIRE SHALL BE SPLICED THROUGH AND INSULATED FROM C. ACTIVATE ALARM BELL UNIT(S) IN ELEVATOR LOBBIES. <br /> CONTACT WITH ANY POTENTIAL GROUND SOURCE. D. TRANSMIT AN "ALARM"SIGNAL TO THE REMOTE MONITORING STATION. <br /> E. RECALL ELEVATOR TO THE PRIMARY FLOOR (FLOOR 1) <br /> F. ACTIVATE ELEVATOR FLASHING FIRE-HAT CONTROL. <br /> G. ACTIVATE HVAC SHUT DOWN RELAY. <br /> 2.2 ACTIVATION OF A HEAT DETECTOR IN THE ELEVATOR MACHINE ROOM <br /> OR TOP OF HOISTWAY SHALL CAUSE THE FOLLOWING TO OCCUR: <br /> A. ILLUMINATE THE RED "ALARM" INDICATOR ON THE ELEVATOR FAR. <br /> B. DISPLAY MESSAGE ON THE CONTROL PANEL LCD DISPLAY INDICATING SCOPE OF WORK <br /> LOCATION INFORMATION FOR THE DEVICE THAT WAS ACTIVATED. <br /> C. ACTIVATE ALARM BELL UNIT(S) IN ELEVATOR LOBBIES. <br /> D. TRANSMIT AN "ALARM"SIGNAL TO THE REMOTE MONITORING STATION. <br /> E. ACTIVATE ELEVATOR POWER SHUNT TRIP BREAKER (SHUTDOWN POWER EOL <br /> TO ELEVATOR). SCOPE OF WORK 1/2 1/1 <br /> F. ACTIVATE HVAC SHUT DOWN RELAY. <br /> y14/2 <br /> AM <br /> 1:59 1:58 1:57 1:56 <br /> S S M4 S EXISTING SLC CIRCUIT <br /> EXISTING <br /> L H PIT �TS SPRINKLER TAMPER <br /> . EOL FACP <br /> H TOP OF SHAFT <br /> FOIL <br /> RISER DIAGRAM <br /> SCALE: N.T.S. <br /> Timothy C.Eastman-263- g2* <br /> NICETC �cayQn i�� 2� PO BOX 9 <br /> �Jrri e Cevel IV AUBURN,9-060 t <br /> REATRON CS 253-s3s-Soso <br /> E�rti 1f Cation o xpires:March 01,2025 FlRE PRo EcnoN sERMces,oa.1 o 9`1 <br /> 10403203 9132326-E2 <br /> SUBTITLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY SEATRON 4,11,24 FIRE DETECTION&ALARM SYSTEM _ - 4.11.24 <br /> A FIRE ALARM SUBMITTAL SEA SEA 4.11.24 THIS DESIGN AND/OR CHECKED BILL OF MATERIAL&NOTES <br /> SPECIFICATION IS APPROVED SHEET 1 <br /> BOE/NG® APPROVED BY DEPT DATE N IN E BREAKROOM AND RESTROOM ADD El <br /> 1 <br /> CHECKED <br /> APPROVED BUILDING 40-027 JOB NO. 10403203 COMP NO. <br /> APPROVED ELECTRICAL MASTER COL 9- 9.8/ Ll EVERETT, WA DWG No. 40-027-E1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.