My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2025 BLDG 40-58 Plans 2025-09-17
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2025 BLDG 40-58 Plans 2025-09-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2025 8:58:41 AM
Creation date
9/17/2025 8:58:32 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
FA2503-015
Year
2025
Notes
ADDING DUAL MONITOR MODULES FOR WATERLOW AND TAMPERS AND CEI
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2503-015 <br /> Site Address: 3003 W Casino Rd BLDG 40-58 <br /> BOEING BUILDING 40-58 PAINT BOOTH Applicant: EVERON LLC <br /> Application Date:03/28/2025 a <br /> Description: Adding dual monitor modules for Tj <br /> waternow and tampers and Get <br /> Review Date: 04/0 712 0 2 5 O <br /> FIRE ALARM SYSTEM w �U <br /> aZ � <br /> EVERETT LIU Z O <br /> Everett Fire Dept.Permit Review Q j <br /> Status:Approved Q Z J 6 <br /> EVERETT, WA 98204 Reviewed By:kbrown <br /> 04/0 7/2 022 5 1 1:33:24 a) W O LO <br /> AM Q OO Q SHEET INDEX GENERAL NOTES O W w <br /> QTY SYMBOL DESCRIPTION MODEL SUPPLIER MOUNTING o H LU <br /> SHEET NO. DESCRIPTION INSTALLATION&GENERAL WIRING NOTES: NUMBER HEIGHT <br /> FA-01 <br /> TITLE SHEET GENERAL NOTES: REMOTE BOOSTER <br /> 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE E(1) NAC POWER SUPPLY FCPS24-S8 NOTIFIER 66"A.F.F TO <br /> WITH NFPA,LOCAL AND STATE AHJ's,NEC AND CONTRACT E (EXISTING) THE TOP <br /> FA-02 TYPICAL WIRING DETAILS&CALCULATIONS DRAWINGS <br /> 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT <br /> INTENDED FOR ACTUAL CONDUIT ROUTING. <br /> FA-03 LEVEL FIRE ALARM PLAN 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL n O FIRE ALARM PC2WL SYSTEM SENSOR CEILING <br /> CONTRACTOR PER NEC AND AHJ. L O HORN STROBE <br /> 4. VERIFY ALL LOCATIONS OF DEVICES WITH <br /> ELECTRICAL/ARCHITECTURAL PLANS.SCALE AND PLACE ALL <br /> DEVICE PER ELECTRICAL/ARCHITECTURAL PLANS. <br /> 5. ALLCIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR DUAL INPUT FDM NOTIFIER CEILING <br /> OPENS,SHORTS,GROUNDS AND PROPER"END-OF-LINE" <br /> RESISTANCE.EACH CIRCUITS METER READING MUST BE 8 DM MONITOR MODULE _ <br /> DOCUMENTED AND PRESENTED TO THE EVERON FIELD <br /> TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP&CHECKOUT. O <br /> 6. AS-BUILTS: <br /> 6.1. A SET OF INSTALLATION AS-BUILT DRAWINGS SHOWING EXISTING TO VERIFY IN O <br /> ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT ... m <br /> ADDING DUAL MONITOR MODULES FOR WATERLOW AND TAMPERS AND BY PROJECT FOREMAN FOR USE BY THE EVERON REMAIN FIELD LOCATION <br /> CEILING MOUNT HORN/STROBES IN FC ROOMS. TECHNICIAN. <br /> 6.2. AS-BUILTS SHALL BE KEPT ORDERLY AND BE CLEARLY RELOCATE EXISTING VERIFY IN L 7 O <br /> MARKED WITH DIFFERENT COLOR PENS FOR EACH CIRCUIT RE W <br /> AND/OR CIRCUIT TYPE AND LABELED PER THE WIRE LEGEND. ... ... <br /> AS-BUILTS MUST INDICATE CHANGES TO THE FINAL DEVICE DEVICE FIELD LOCATION Q N <br /> INSTALLED LOCATIONS IF NOT INSTALLED AT LOCATION /^ N 00 <br /> SHOWN ON DESIGN DOCUMENTS. 00 >- 0 Ci) <br /> 6.3. AS-BUILT REDLINES NOT PROVIDING THIS INFORMATION WILL A.F.F ABOVE FINISHED VERIFY IN O Q BE RETURNED TO THE INSTALLATION CONTRACTOR FOR ... ... U7 > I— <br /> CORRECTION.EVERON IS NOT RESPONSIBLE FOR THESE FLOOR FIELD LOCATION O Z <br /> W <br /> DELAYS. W'^ <br /> 7. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS I vJ W <br /> WILL BE MADEWITH THE EVERON PROJECT MANAGER. END OF LINE VERIFY IN (D < Q _ <br /> 8. ALL EVERON FIELD SERVICES MUST BE SCHEDULED WITH THE <br /> EVERON PROJECT MANAGER WITH A MINIMUM OF 14 WORKINGS RESISTANCE -" -" FIELD LOCATION \J W <br /> DAYS ADVANCE NOTICE. Z J M W <br /> Q W <br /> 9. DO NOT INSTALL LINE VOLTAGE IN SAME CONDUIT AS POWER 0 Q � J <br /> LIMITED CABLES. J W O W <br /> LEGENDS W M > H <br /> m LL W <br /> Z_ <br /> W <br /> APPLICABLE CODES O <br /> m <br /> NFPA 72 2019 EDITION <br /> IBC 2018 EDITION WITH WASHINGTON AMENDMENTS <br /> NFPA 70(NEC)2017 EDITION <br /> SCOPE OF WORK <br /> Z <br /> CODE INFORMATIONS <br /> s �: ;:: <br /> WIRE DESIGNATION o 0 0 0 <br /> SYMBOL CIRCUITTYPE DESCRIPTION <br /> �• _ I aaaaa <br /> ' ri7 t � .• - - ,��a O Fill D SLC ADDRESSABLE LINE 16/2AWG FIRE RATED CABLE <br /> :a{S O Q>9SI : 11 -p e t S STROBE CIRCUIT 14/2AWG FIRE RATED CABLE <br /> V PREPARED APL <br /> REVIEW RM <br /> — } <br /> - F - - I-• y•r MMIDDIYI' 12/21122 <br /> O;• ra!' '� -J�a ". SCALE NOT TO SCALE <br /> T— Gs <br /> f ' <br /> JOB NO. 501209854 <br /> :Iy NOTES: <br /> O - a Drawing PreparedlReviewed by: <br /> • O "STRIPES ARE NOT REQUIRED,HOWEVER IT DOES MAKE IT EASIER FOR CIRCUIT IDENTIFICATION. <br /> Daniel J.Kelso <br /> • 0 -n,O 1.WIRE MANUFACTURER IS FOR REFERENCE PURPOSE ONLY.WHEN USING OTHER MANUFACTURE,ENSURE PROPER CROSS REFERENCE <br /> NICET Certification#149793 <br /> ® 2.FPLP CAN BE USED IN MOST ALL APPLICATIONS WITH THE EXCLUSION OF WET AND CIRCUIT INTEGRITY REQUIREMENTS Fire Alarm Systems-Level III <br /> O 3-INSTALL WIRING PER NEC.USE CABLE TYPE CONSISTENT WITH NEC REQUIREMENTS,IE:PLENUM,RISER,UNDERGROUND,ETC. <br /> Expiration: 2028-03-01 <br /> VICINITY MAP <br /> SHEET FA-01 <br /> 0 2024 Everon.All rights reserved.The product/se es listed in this document are marks and or registered marks of their respective owners and used under license.Unauthorized use strict) prohibited. <br />
The URL can be used to link to this page
Your browser does not support the video tag.