Laserfiche WebLink
City of Everett <br /> ' Everpark Garage Repairs Addendum No.4 <br /> Response: Corrosion inhibiting products in both Specification 030130 Sections 2.4 A and 2.4 B <br /> should be provided per Note 2 in both Details 19 and 20/S.11. This is intended to apply at the <br /> patch locations, as noted. The Surface Applied Corrosion-Inhibiting Treatment should extend 6 <br /> inches minimum past the extents of the patch along the path of the reinforcing at each <br /> ' reinforcing location. <br /> ITEM 5—Can a base bid quantity and unit price be established for the overhead beam repairs as <br /> ' was done with the floor repairs? <br /> Response: Per Detail 19/S.11, a 3-inch minimum overhead patch width is expected. Note that <br /> ' typical overhead patches each run along the length of a single bar, so the total quantity should <br /> be straight-forward to determine from the plan. Please see the attached, revised Bid form in <br /> Addendum 3 requiring a unit price for additional patching. A base value of 30 additional lineal <br /> feet is expected. <br /> All other requirements of the plans and specifications remain in effect. <br /> This addendum shall be attached to and made part of the plans and specifications and shall be <br /> acknowledged on the bidder's proposal. <br /> ' END OF ADDENDUM NO.4 <br /> Page 3 of 3 <br />