Laserfiche WebLink
1 City of Everett <br /> Everpark Garage Repairs Addendum No. 3 <br /> I <br /> ITEM 9 What is the requirement for dust partitions around our work areas? <br /> I <br /> Response: See Specification 01 5700 Section 1.10 DUST CONTROL. <br /> ITEM 10— Is Ground Penetrating Radar testing required prior to deteriorated concrete removal <br /> I <br /> and routing of the slab for the supplemental reinforcement placement at the floor patches due <br /> to the PT construction? <br /> I <br /> Response: Use of ground penetrating radar (GPR) is not required by the design documents. Use <br /> GPR is permissible as a means and methods issue. <br /> I <br /> ITEM 11 —Specification section 01 3544, 1.2, B states that no claims for additional work will be <br /> allowed if any ACM are discovered. When was this structure built? Does the owner have any <br /> knowledge of ACM's on this site? Does this apply to lead based paint if discovered? <br /> IResponse: a. Note the following corrections to Specification 01 3544— Hazardous Materials <br /> Procedures: PART 1—GENERAL, Section 1.1 Summary: strike out the following from paragraph: <br /> I <br /> detached Duplex Building located west <br /> b. Section 1.2 ASBESTOS REMEDATION: Omit from specification 01 3544 section 1.2, paragraph <br /> 1 B. <br /> c. It is presumed that all paint within the building contains traces of lead,the Contractors shall <br /> I provide lead remediation plan as part of their Health and Safety plan. The contractors shall <br /> follow all applicable Federal, State and local ordinances, regulations and rules pertaining to <br /> lead. <br /> IITEM 12—Specification section 01 7423, 3.1, B and E require the contractor to provide pest <br /> control and storm/sewer line cleaning at the completion of the work. Please confirm these are <br /> 1 required for this project. <br /> Response: Specification 01 7423 section 3.1, B and E: Are not required for this project. Omit <br /> 1 from Specification 017423 section 3.1, B and E. <br /> ITEM 13—Specification section 030130, 2.4, B and 3.10 require installation of a Surface Applied <br /> 1 Corrosion Inhibiting Treatment per the drawings. No note requiring this was seen on the <br /> drawings. Please clarify if and where this is required. <br /> 1 Response: See Detail 20/S.11, Note 2, and Detail 19/S.11, Note 2, for corrosion-inhibiting <br /> coating requirements provided in the drawings. <br /> 1 ITEM 14—Specification section 030130, 2.5, A and 3.11 require installation of a Methacrylate <br /> Polymer Sealer to the traffic bearing surfaces, including parking areas and walks. No note <br /> 1 requiring this was seen on the drawings. Please clarify if and where this is required. <br /> I <br /> Page 3 of 5 <br /> I <br />