My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:46:08 PM
Creation date
9/12/2019 2:11:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1809-027
Year
2018
Notes
INSLATT NEW COMPRESSORON GROUND FLOOR DRYER PADS MEZZANINE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBSTATIONS 11-1 AND 11-2 SECTION 26 11 16 <br /> PROJECT#22349762 SECONDARY UNIT SUBSTATIONS <br /> BOEING- EVERETT SITE SERVICES <br /> c. Fault close asymmetrical rating of 61 kA. <br /> d. Fused switch fault close rating of 99 kA Asym rms. <br /> B. Windows: Provide with three rupture-proof viewing windows; two to inspect each set of <br /> switchblades, and one to view the blown fuse indicators (where the selected fuse type <br /> has such indicators). <br /> C. Fuses: Fuses shall be sized as recommended by the transformer manufacturer, <br /> consideririg fan cooling, temperature-rise specification, and cycle loading. Comply with <br /> the following: <br /> 1. The selected fuse size shall achieve the best balance of IEEE/ANSI recommended <br /> protection levels, load carrying capability, and coordinate properly with the secondary <br /> switchgear breakers. <br /> 2. The sizes shown on the drawings are approximate, and are subject to revision by the <br /> manufacturer, if required, with no change in price. <br /> 3. Current-limiting type, rated minimum of 50-kA RMS symmetrical current-interrupting <br /> capacity. <br /> a. Gould-Shawmut CS-3 <br /> b. Cutler-Hammer CLE <br /> c. General Electric EJO-1, Type 9F62 <br /> 4. Indicator integral with each fuse to show when it has blown. <br /> 5. Spares: Include three fuses in use and three spare fuses in storage clips in switch. <br /> D. Construction. <br /> 1. Dual gang operated quick make/quick break mechanisms which shall operate the <br /> contacts independently of the speed of movement of the operating handle. The <br /> operating handle shall be non-removable. <br /> 2. The mechanism shall be field adjustable for alignment, open gap, and sequencing. <br /> 3. All switch current carrying components, fuse clips, interconnecting buses, outgoing <br /> buses, and incoming lug landings shall be copper, with silver plating at joints and <br /> terminations. <br /> 4. All buses and conductors shall be insulated, except for the switch moving parts and <br /> contacts. Insulation on buses shall consist of Noryl sleeves, or fluidized bed epoxy. <br /> Corners, joints, insulator connection points, and the lug landing pads shall be <br /> insulated with removable PVC boots. Coordinate the boots for the lug landing pads <br /> with the number and size of cable terminations identified. Heat shrink coverings and <br /> insulated tapes are not acceptable. <br /> 5. All live parts shall be insulated from ground by polyester. <br /> 6. The switch connecting rods shall be polyester insulated. <br /> 7. The switch load side bus shall be connected to the transformer incoming terminals <br /> via cables. <br /> 8. Each primary termination provision shall have adequate space for termination of four <br /> (4) 15kV 500 kcmil shielded cables per phase from the top and bottom of the air <br /> terrninal chamber, including adequate allowance for cable bending limitations. <br /> a. Provide A.B. Chance ground stud, part#C600-2102, on accessible part of <br /> phase bus in each switch for connection of owner's maintenance grounding <br /> equipment <br /> 2611 16-7 <br /> (07/15/18) <br />
The URL can be used to link to this page
Your browser does not support the video tag.