3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:46:08 PM
Creation date
9/12/2019 2:11:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1809-027
Year
2018
Notes
INSLATT NEW COMPRESSORON GROUND FLOOR DRYER PADS MEZZANINE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBSTATIONS 11-1 AND 11-2 SECTION 26 11 16 <br /> PROJECT#22349762 SECONDARY UNIT SUBSTATIONS <br /> BOEING- EVERETT SITE SERVICES <br /> K. Provide safety signs per current regulatory requirements, including the following at <br /> minimum. <br /> 1. High voltage section shall be marked with a sign at all the access points that a <br /> hazard exists using the words <br /> WARNING: 12,470 VOLTS <br /> LOCK-OUT ALL SOURCES INCLUDING <br /> THE SECONDARY MAIN,TEST AND GROUND-OUT <br /> BEFORE WORKING INSIDE <br /> 2. For tie breaker and compartments which contain separate sources of power. <br /> WARNING: 2400 VOLTS <br /> THIS CUBICLE CONTAINS VOLTAGE FROM <br /> MULTIPLE SOURCES <br /> LOCK OUT ALL SOURCES, <br /> TEST AND GROUND OUT BEFORE WORKING INSIDE <br /> 3. Provide signs on the rear wiring compartment of all feeder breakers using the <br /> wording. <br /> WARNING: 2400 VOLTS <br /> THE CABLE TERMINALS MAY BE ENERGIZED <br /> LOCKOUT SOURCE,TEST AND GROUND OUT <br /> BEFORE WORKING INSIDE <br /> 2.02 PRIMARY SWITCH <br /> A. General Requirements: <br /> 1. Dual three pole, single throw, dead front, metal enclosed, with manual stored energy <br /> operator, with fuses mounted on a single frame,complying with IEEE C37.20.3. <br /> 2. Key interlocking shall be provided to accomplish the following: <br /> a. Inhibit both switches from being closed simultaneously. <br /> b. Guard both switch front access doors from being opened when either duplex <br /> switch is closed, or the secondary main/isolation is closed. <br /> c. Inhibit opening and closing of either primary switch with the secondary <br /> main/isolation switch closed. <br /> 3. Phase barriers: Located between blades and fuses of each phase, designed for <br /> easy removal, allows visual inspection of switch components when barrier is in place. <br /> 4. Accessory Set: Tools and miscellaneous items required for interrupter switchgear <br /> test, inspection, maintenance, and operation. Include fuse-handling tool as <br /> recommended by switchgear manufacturer. <br /> 6. Continuous-Current Rating: 600 A. Switch Interrupting Rating: 600A <br /> 7. Minimum No Load Duty (Operations): 500A <br /> 8. Short-Circuit Rating: <br /> a. Short-time momentary asymmetrical fault rating of 61 kA. <br /> b. 2-second symmetrical rating of 38-kA RMS. <br /> 2611 16 - 6 <br /> (07/15/18) <br />
The URL can be used to link to this page
Your browser does not support the video tag.