My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:46:08 PM
Creation date
9/12/2019 2:11:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1809-027
Year
2018
Notes
INSLATT NEW COMPRESSORON GROUND FLOOR DRYER PADS MEZZANINE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBSTATIONS 11-1 AND 11-2 SECTION 26 11 16 <br /> PROJECT#22349762 SECONDARY UNIT SUBSTATIONS <br /> BOEING - EVERETT SITE SERVICES <br /> The drawing must conform to the spacing requirements elucidated on the plan <br /> drawings included with the bid package, include the weights of the various <br /> components of the substation, and depict the conduit entrances provided. <br /> c. Provide transformer nameplate data, rating of each winding, phase relation of each <br /> winding, cooling method used to achieve each rating, temperature rise, BIL, <br /> impedance, X/R, guaranteed maximum sound levels, liquid volume (if applicable), <br /> and guaranteed voltage regulation table. <br /> E. Submittals Required Prior to Manufacturing: <br /> 1. Prior to manufacture of equipment, manufac�urer shall provide submittals for approval <br /> by Boeing Engineer. Submittals shall be provided as complete sets and shall be <br /> neatly bound under a single cover and properly indexed. Three (3) complete sets <br /> shall be provided. One (1) set will be returned with appropriate comments. Owner <br /> shall have 15 calendar days after receipt of submittals to review and return them to <br /> the manufacturer. <br /> 2. If modifications to the submittals are necessary, manufacturer shall have 15 calendar <br /> days to revise and resubmit the drawings. The Owner shall have an additional 15 <br /> calendar days to review and return them to the manufacturer, for each subsequent <br /> review required. The submittal shall contain at minimum the following. <br /> a. Bill of material, catalog cut sheets and manufacturers standard literature <br /> describing the equipment,components, options, and auxiliary devices. <br /> b. Equipment technical data, including all ratings, performance characteristics, and <br /> efficiency. <br /> c. Dimensioned outline drawings (front, rear, top, side views) of equipment with <br /> installed weights, center of gravity and weight of each shipping article. Final <br /> weights and center of gravity of the equipment when installed. <br /> d. Locations of main power bus entries, mounting details, conduit locations for <br /> auxiliary equipment, and locations for mechanical service interface points. <br /> Identify clear spaces required for maintenance around the equipment. Identify <br /> conduit entrance locations and sizes. <br /> e. One-line, three-line, and schematic wiring diagrams for the main power circuits, <br /> and auxiliary equipment. <br /> f. Instructions for handling and installation. Foundation loading diagram. <br /> g. Nameplate legends. <br /> F. Submittal Required With Delivery: <br /> a. Provide three copies of the Operating and Maintenance Manual. <br /> b. Provide three copies of Test Reports. <br /> c. Provide one set of certified, as-built drawings on compact disk. <br /> d. Shop drawings shall be provided to Boeing on AutoCAD Version 2008. <br /> e. Provide written safety procedure for operating, maintaining, and repairing the <br /> equipment. <br /> f. Provide material safety data sheets (MSDS)for all applicable substances. <br /> 1.04 QUALIFICATIONS <br /> A. The following manufacturers are acceptable. <br /> 1. Primary Duplex Switch: <br /> 2611 16 -3 <br /> (07/15/18) <br />
The URL can be used to link to this page