3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:46:08 PM
Creation date
9/12/2019 2:11:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1809-027
Year
2018
Notes
INSLATT NEW COMPRESSORON GROUND FLOOR DRYER PADS MEZZANINE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBSTATIONS 11-1 AND 11-2 SECTION 26 11 16 <br /> PROJECT#22349762 SECONDARY UNIT SUBSTATIONS <br /> BOEING - EVERETT SITE SERVICES <br /> be replaced. The warranty is to include labor and material, and the repairs are to be <br /> performed at the site of the equipment installation and at the date and time scheduled by <br /> the Owner. <br /> PART2- PRODUCTS <br /> 2.01 GENERAL <br /> A. Equipment shall be UL Listed. Alternate means of having equipment acceptable for <br /> installation and operation by authority having jurisdiction shall be identified as part of the <br /> bid. <br /> B. The enclosure of the unit substation and each subassembly contained therein shall be in <br /> accordance with the protection requirements of NEMA ICS 2005 and shall be suitable for <br /> indoor use. <br /> C. The equipment shall be suitable for installation in a location accessible to qualified <br /> personnel and authorized personnel only. <br /> D. The components of the unit substation shall be coordinated by the manufacturer(s) for <br /> bolt-together assembly, flush-front arrangement. <br /> E. Provide access to all equipment via hinged doors. <br /> 1. Primary switches shall have heavy duty 3-point handle-type latch mechanism on the <br /> front and rear door. All latch mechanisms shall have provisions for padlocking. <br /> 2. Front compartments of the low voltage switchgear shall have latches. <br /> 3. All other doors shall utilize captive bolts (transition sections, transformer access <br /> doors and rear of low voltage switchgear). All captive bolts shall be 6-point, and shall <br /> engage welded nuts in the equipment structure, not tapped holes in sheet metal, <br /> cage nuts, or nuts affixed by a pressure process. The maximum width of doors must <br /> not exceed 24 inches unless identified specifically as a deviation and approved in <br /> writing. <br /> F. Provide each shipping section of the equipment with provisions for overhead lifting. <br /> G. Provide the base of each shipping section suitable for rolling on pipes or skates, and for <br /> fork lift transportation. <br /> H. All internal steel components shall be painted ANSI 61. All external steel components <br /> shall be painted the same shade of ANSI 61 light gray. The painting system shall include <br /> cleaning, phosphating, and an electro statically applied finish coat. <br /> I. All hardware used in the equipment shall be grade 5. Access and operating handles <br /> shall be stainless steel, zinc or cadmium plated. The exterior of outdoor equipment shall <br /> have hardware, exposed unpainted metal components, access handles, and operating <br /> handles of stainless steel only. <br /> J. The main metering compartment's meters and displays shall be completely readable from <br /> an eye level of 5 feet. Switchgear metering compartments' meters and displays shall be <br /> less than 6 feet. <br /> 2611 16 -5 <br /> (07/15/18) <br />
The URL can be used to link to this page
Your browser does not support the video tag.