2. Pleasc submit the testcd asscmblies on the drawings for one-hour fire resistance rated construction and <br />reference them to all new construction. This includcs second tloor framing and supporting columns and <br />walls, new interior stairs, bearing walls on the first floor, and walls and soffits within enclosed usablc <br />spaces under enclosed and unenclosed stninvays, per IBC section 1009.5.3 and the consWction rype <br />rcquired for the building of Type Ill-A construction, per [BC table 601. <br />3. The location of &amed walls in the ficld does not match thc submitted drawings for permit. This has <br />bcen noted in an inspection report, since the perniit has not yet been issued. Please revise the drawings <br />for plan review wherc required. <br />4. The fonner elevator sl�aR has not bcen Gamed at the second floor as shown on the drawings. Plcase <br />revise the drawings for plan review. <br />5. Thc guard and handrail for the new extcrior cxit stair from the 2"� flaor does not meet minimum code <br />requirements. Plcase revis� and resubmit the drawings to indicate: <br />a. The guard is rcquircd wl�ere tlicre is more than a 30-inch drop adjaccnt to the walking surfacc, <br />per IDC section 1013.1. <br />b. The guard is required to bc 42 inclies high, per IBC section 1013.2. <br />a A 4-inch sphere should not pass through thc guard up ro a height of 34 inches, per II3C section <br />10133. <br />d. From a height of 34 inches to 42 inches, a sphere 8 inches in diameter should not pass through <br />the guard, per IBC section 10133. <br />c. The triangular opening fonned by the riscr, tread and bottom rail should not allow ti.e passagc <br />oPa G-inch sphere through the guard, per IBC section 10133. <br />f. A handrail (in addition to the guard on the outside of the stair) is required on both sides of the <br />ncw exit stair, per IBC 1009.10. <br />g. The handrail sl�oulJ be no higher than 38 inchcs and not less than 34 inches above the walking <br />surface, per I13C section 1012.2. <br />h. 1lanJrail extcnsions arc required at the top and bottom of thc stair run, per IBC section I OI2.S. <br />1'he handrails should eatcnd liorizontally at least l2 inches beyond thc top riscr and continuc to <br />slope for the depth oPone trcad bcyond the bottom riscr. <br />These comments address building issues only. Other dcpartments (such as Utilities, Planning or Pirc) may <br />require additional revisions or additions. Upon submission of hvo inscrt sets of revised dr:�wings reflecting <br />the conections rcquested, your application will be proccssed. AII required submittals must bc uf sufiicient delail <br />and information to ensure that the proposed slructurc will bc constructed in compliance with all adopted codes. <br />You can rcach me dircetly to discuss lliis Icttcr by e-mail at mhaleWr� ci.everott.wa.us or by phone at 425-: 57- <br />8813. <br />Cc: Pastor Peter Kulakevich, I larvest Christian Cenl <br />Steve Miller, P.G, COG � <br />2 <br />