My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
830 SE EVERETT MALL WAY HARVEST CHRISTIAN CENTER 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
830
>
HARVEST CHRISTIAN CENTER
>
830 SE EVERETT MALL WAY HARVEST CHRISTIAN CENTER 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/7/2019 3:08:17 PM
Creation date
10/7/2019 2:52:20 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
830
Tenant Name
HARVEST CHRISTIAN CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
206
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. Pleasc submit the testcd asscmblies on the drawings for one-hour fire resistance rated construction and <br />reference them to all new construction. This includcs second tloor framing and supporting columns and <br />walls, new interior stairs, bearing walls on the first floor, and walls and soffits within enclosed usablc <br />spaces under enclosed and unenclosed stninvays, per IBC section 1009.5.3 and the consWction rype <br />rcquired for the building of Type Ill-A construction, per [BC table 601. <br />3. The location of &amed walls in the ficld does not match thc submitted drawings for permit. This has <br />bcen noted in an inspection report, since the perniit has not yet been issued. Please revise the drawings <br />for plan review wherc required. <br />4. The fonner elevator sl�aR has not bcen Gamed at the second floor as shown on the drawings. Plcase <br />revise the drawings for plan review. <br />5. Thc guard and handrail for the new extcrior cxit stair from the 2"� flaor does not meet minimum code <br />requirements. Plcase revis� and resubmit the drawings to indicate: <br />a. The guard is rcquircd wl�ere tlicre is more than a 30-inch drop adjaccnt to the walking surfacc, <br />per IDC section 1013.1. <br />b. The guard is required to bc 42 inclies high, per IBC section 1013.2. <br />a A 4-inch sphere should not pass through thc guard up ro a height of 34 inches, per II3C section <br />10133. <br />d. From a height of 34 inches to 42 inches, a sphere 8 inches in diameter should not pass through <br />the guard, per IBC section 10133. <br />c. The triangular opening fonned by the riscr, tread and bottom rail should not allow ti.e passagc <br />oPa G-inch sphere through the guard, per IBC section 10133. <br />f. A handrail (in addition to the guard on the outside of the stair) is required on both sides of the <br />ncw exit stair, per IBC 1009.10. <br />g. The handrail sl�oulJ be no higher than 38 inchcs and not less than 34 inches above the walking <br />surface, per I13C section 1012.2. <br />h. 1lanJrail extcnsions arc required at the top and bottom of thc stair run, per IBC section I OI2.S. <br />1'he handrails should eatcnd liorizontally at least l2 inches beyond thc top riscr and continuc to <br />slope for the depth oPone trcad bcyond the bottom riscr. <br />These comments address building issues only. Other dcpartments (such as Utilities, Planning or Pirc) may <br />require additional revisions or additions. Upon submission of hvo inscrt sets of revised dr:�wings reflecting <br />the conections rcquested, your application will be proccssed. AII required submittals must bc uf sufiicient delail <br />and information to ensure that the proposed slructurc will bc constructed in compliance with all adopted codes. <br />You can rcach me dircetly to discuss lliis Icttcr by e-mail at mhaleWr� ci.everott.wa.us or by phone at 425-: 57- <br />8813. <br />Cc: Pastor Peter Kulakevich, I larvest Christian Cenl <br />Steve Miller, P.G, COG � <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.