Laserfiche WebLink
I <br /> 11 <br /> 2 3. Compute the lower quality index (QL): <br /> I 3 <br /> 4 ,X,, —LSL <br /> I. <br /> s <br /> I 5 <br /> 6 Where: <br /> 7 LSL = 92.0 <br /> I 8 <br /> 9 4. Determine PL (the percent within the lower Specification limit which corresponds to <br /> 10 a given QL) from Table 1. For negative values of QL, PL is equal to 100 minus the <br /> 11 table PL. If the value of QL does not correspond exactly to a figure in the table, use <br /> 12 the next higher value. <br /> 13 <br /> 14 5. Determine the quality level (the total percent within Specification limits): <br /> I 15 <br /> 16 Quality Level = PL <br /> 17 <br /> I 18 6. Using the quality level from step 5, determine the composite pay factor (CPF) from <br /> 19 Table 2. <br /> 20 <br /> I 21 7. If the CPF determined from step 6 is 1.00 or greater: use that CPF for the <br /> 22 compaction lot; however, the maximum HMA compaction CPF using an LSL = <br /> 23 92.0 shall be 1.05. <br /> 24 <br /> 25 8. If the CPF from step 6 is not 1.00 or greater: repeat steps 3 through 6 using an <br /> 26 LSL = 91.5. The value thus determined shall be the HMA compaction CPF for that <br /> 27 lot; however, the maximum HMA compaction CPF using an LSL = 91.5 shall be <br /> 28 1.00. <br /> 29 <br /> 30 1-06.2(2)D1 Quality Level Analysis <br /> I 31 The following new sentence is inserted after the first sentence: <br /> 32 <br /> 33 The quality level calculations for HMA compaction are completed using the formulas in <br /> 34 Section 1-06.2(2)D5. <br /> I 35 <br /> 36 1-06.2(2)D4 Quality Level Calculation <br /> 37 The first paragraph (excluding the numbered list) is revised to read: <br /> I 38 <br /> 39 The procedures for determining the quality level and pay factors for a material, other than <br /> 40 HMA compaction, are as follows: <br /> I 41 <br /> 42 1-06.6 Recycled Materials <br /> 43 The first three sentences of the second paragraph are revised to read: <br /> I 44 <br /> 45 The Contractor shall submit a Recycled Material Utilization Plan on WSDOT Form 350- <br /> 46 075A within 30 calendar days after the Contract is executed. The plan shall provide the <br /> 47 Contractor's anticipated usage of recycled concrete aggregates for meeting the <br /> I 48 requirements of these Specifications. The quantity of recycled concrete aggregate will be <br /> 49 provided in tons and as a percentage of the Plan quantity for eligible material listed in <br /> I City of EverettPage AM-5 Amendments <br /> Everett Station 80 Stall Parking Expansion June 2019 <br /> I <br />