Laserfiche WebLink
1 Section 7-02, Culverts <br /> 2 April 2, 2018 <br /> 3 7-02.2 Materials <br /> 4 In the first paragraph, the references to "Portland Cement" and "Aggregates for Portland <br /> 5 Cement Concrete" are revised to read: <br /> 6 <br /> 7 Cement 9-01 <br /> 8 Aggregates for Concrete 9-03.1 <br /> 9 <br /> 10 7-02.3(6)A4 Excavation and Bedding Preparation <br /> 11 The first sentence of the third paragraph is revised to read: <br /> 12 <br /> 13 The bedding course shall be a 6-inch minimum thickness layer of culvert bedding material, <br /> 14 defined as granular material either conforming to Section 9-03.12(3) or to AASHTO Grading <br /> 15 No. 57 as specified in Section 9-03.1(4)C. <br /> 16 <br /> 17 Section 7-05, Manholes, Inlets, Catch Basins, and Drywells <br /> 18 August 6, 2018 , <br /> 19 7-05.3 Construction Requirements <br /> 20 The fourth sentence of the third paragraph is deleted. <br /> 21111 <br /> 22 Section 7-08, General Pipe Installation Requirements <br /> 23 April 2, 2018 <br /> 24 7-08.3(3) Backfilling <br /> 25 The fifth sentence of the fourth paragraph is revised to read: <br /> 26 <br /> 27 All compaction shall be in accordance with the Compaction Control Test of Section 2- <br /> 28 03.3(14)D except in the case that 100% Recycled Concrete Aggregate is used. <br /> 29 <br /> 30 The following new sentences are inserted after the fifth sentence of the fourth paragraph: <br /> 31 <br /> 32 When 100% Recycled Concrete Aggregate is used, the Contractor may submit a written 11133 request to use a test point evaluation for compaction acceptance. Test Point evaluation <br /> 34 shall be performed in accordance with SOP 738. <br /> 35 <br /> 36 Section 8-01, Erosion Control and Water Pollution Control , <br /> 37 April 1, 2019 <br /> 38 8-01.1 Description <br /> 39 This section is revised to read: <br /> 40 <br /> 41 This Work consists of furnishing, installing, maintaining, removing and disposing of best <br /> 42 management practices (BMPs), as defined in the Washington Administrative Code (WAC) <br /> 43 173-201A, to manage erosion and water quality in accordance with these Specifications <br /> 44 and as shown in the Plans or as designated by the Engineer. <br /> 45 <br /> City of Everett Page AM-68 Amendments <br /> Everett Station 80 Stall Parking Expansion June 2019 <br /> I <br />