Laserfiche WebLink
Plan Check Number: B1907-001, First Building Review <br /> 1225 E Casino Road, Everett, 98203 <br /> August 7, 2019 <br /> Page 2 <br /> Structural <br /> Structural Correction Item #1: <br /> The "Applicable Codes and Standards"section of the General Notes on Sheet S-1.00 <br /> specifies the latest editions IBC and IRC as the governing codes. The notes shall be revised <br /> to specify the 2015 editions. See the Everett Municipal Code Section 16.005.030 Articles A <br /> and B. <br /> Response to Structural Correction Item #1: <br /> The drawing general notes, "Applicable Codes and Standards" have been updated to specify <br /> the 2015 editions of the IBC and the IRC. <br /> Structural Correction Item #2: <br /> Geotechnical special inspections are required for this project. A statement on special <br /> inspections has not been provided and shall be submitted with the permit documents. The <br /> statement shall include a table listing each type of special inspection and shall specify the <br /> extent of each inspection (e.g., continuous, periodic) per IBC Section 1704.3.1. See IBC <br /> Sections 107.1, 1704.2.3 and 1704.3. <br /> Response to Structural Correction Item #2: <br /> The drawing general notes have been expanded to include a Special Inspections section per <br /> IBC Table 1705.6. <br /> Structural Correction Item #3: <br /> Structural observation during construction is required for this project. The structure shall be <br /> observed for instability and damage during the structural jacking operations. A note <br /> specifying the requirement for structural observation by the structural engineer shall be <br /> added to the General Notes on Sheet S-1.00. See IBC Section 1704.6. <br /> Response to Structural Correction Item #3: <br /> The drawing general notes have been expanded to include a Structural Observations section <br /> per IBC section 1704.6 <br /> Foundation System: <br /> Structural Correction Item #4: <br /> The proposed work is not clear. The Repair Plan 2/S-1.00 and Section 2/S-2.00 appear the <br /> interior footing and posts are new. However, Repair Plan includes a note referencing one of <br /> the footings and states "(E) POST AND FOOTING, LOCATIONS APPROXIMATE,TYP". The <br /> required work shall be clarified. If the interior foundation system includes both existing and <br /> new foundations,the drawings shall be revised to clearly differentiate between the <br /> foundations. See IBC Sectcion 107.2.1. <br /> TOWER ENGINEERING COMPANY l *-*<-- <br /> 21907 <br /> --21907 64th Avenue West, Suite 140, Mountlake Terrace, WA 98043-2298 <br />