Laserfiche WebLink
PLUMBING FIXTURE SCHEDULE AIR DEVICE SCHEDULE <br /> CARNEGIE <br /> MARK FIXTURE TYPE AIRFLOW FRAME TYPE FINISH MATERIAL ACC. NOTES MARK B U I L D I N G - <br /> WASTE VENT RL ORL CW HW NOTES MARK MARK MANUFACTURER/MODEL NO. SUPPLY/ DESCRIPTION i TYPE NECK SIZE FACE SIZE SLOT <br /> (IN) (IN) (IN) (IN) (IN) (IN) RETURN / (BORDER TYPE) (LxV� (LxV1n QTY/WIDTH RANGE <br /> EXH �,N> �,N, �#„N, <25 NC R E S TO R A TI 0 N . <br /> L-1 LAV-COUNTER MOUNT 1-1/2" 1-1/2" - - 1/2" 1/2" NOTE 9 L-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 6" DIA 24x24 - 0 - 150 1 WHITE STEEL 4 WAY A JOO� OAK ES AVE. <br /> WC-1 WATER CLOSET � 4" 2" - - 1-1/4" - NOTE 2 WC-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 8" DIA 24x24 - 170 -220 1 WHITE STEEL 4 WAY A EVERETT, WA 982�1 <br /> UR-1 URINAL 2" 1-1/2" - - 1" - NOTE 2 UR-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 10" DIA 24x24 - 250 - 350 1 WHITE STEEL 4 WAY A <br /> i U �" <br /> DS-1 SINK- BREAKROOM 1-1/2" 1-1/2" - - 1J2" 1/2" NOTE 1 DS-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 12" DIA 24x24 - 375-475 1 WHITE STEEL 4 WAY A a <br /> � � <br /> DF-1 DRINKING FOUTAIN 2" 1-1/2" - - 1/2" - DF-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 14" DIA 24x24 - 500-650 1 WHITE STEEL 4 WAY A � <br /> � <br /> MS-1 MOP SINK 3" 2" - - 3/4" 3/4" MS-1 , � , <br /> � � <br /> NOTES: B TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN PER PLANS 12x12 - 0 -450 1 WHITE STEEL 4 WAY B � <br /> A. PIPE SIZES LISTED MAY BE DIFFERENT THAN THE ACTUAL FIXTURE CONNECTION. PROVIDE BRANCH PIPE OF �ISTED �I <br /> SIZE AND ALL PIPE FITTINGS AND OFFSETS REQUIRED FOR COMPLETE iNSTALLATION. C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 10x10 12x12 UP TO 450 1 WHITE ALUMINUM PFA C � <br /> �--� <br /> .�..� <br /> B. PROVIDE FINAL CONNECTIONS TO ALL FIXTURES. � <br /> C. PROVIDE WALL CLEANOUTS FOR ALL SINKS, WATER CLOSETS, AND URINALS. C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x10 24x12 UP TO 700 1 WHITE ALUMINUM PFA C � <br /> C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x22 24x24 UP TO 1600 1 WHITE ALUMINUM PFA C U <br /> NOTES: - <br /> 1. PROVIDE INSTANTANEOUS ELECTRIC WATER HEATER AS NOTED ON DRAWINGS. C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x46 24x48 UP TO 3000 1 WHITE ALUMINUM PFA c 2813 ROCKEFELLER AVE <br /> 2. ADA COMPLIANT WHERE INDICATED ON THE ARCHITECTURAL DRAWINGS. MOUNTING HEIGHT AS INDICATED EVERETT, WA 98201 � <br /> ON ARCHITECTURAL DRAWINGS. PHONE: 425.3'I 7.$O�7 <br /> D TITUS FLOWTEE SUPPLY LINEAR DIFFUSER W/ PLENUM HARD OR LAY-IN PER PLANS 48x10 PER PLANS 0-400 1 WHITE STEEL 1 WAY NOTE 1 o FAX: 425.3'I 7.8489 <br /> E TITUS 272RL SUPPLY SIDE WALL SUPPLY GRILLE HARD OR LAY-fN PER PLANS PER P�ANS - PER PLANS 1 WHITE STEEL 2 WAY E ` <br /> NOTES: <br /> 1. REFER TO PLANS FOR MODEL NUMBER, INLET SIZE, SIZE AND NUMBER OF SLOTS, ETC. PROVIDE FIELD-BUILT PLENUM TO SUIT AVAILABLE SPACE ABOVE CEILING. <br /> CABINET UNIT HEATER SCHEDULE <br /> MARK LOCATION AREA SERVED MANUFACTURER/MODEL NO. TYPE AIRFLOW FAN MOTOR EL.ECTRIC HEATING COIL ELECTRICAL PHYSICAL MOUNTING / NOTES MARK <br /> (CFM) RPM HP/WATTS TOTAL EAT LAT STAGES U�� AMPS LxWxH WEIGHT SUPPORT <br /> CAPACITY (DEG F) (DEG F) (#) (A) (INxINxIN) (LBS) � �, �,'' _ <br /> CUH-1 VESTIBULE 200 VESTIBULE 200 TRANE FFHB0302BMOCOC3BAU VERTICAL RECESSED 320 1750 .04 �4.5� 55 95 2 208/1 11.6 47x10x30 80 WALL 1 CUH-1 � �'�.,� <br /> � � �� � <br /> CUH-2 RISER ROOM 101 RISER ROOM 101 TRANE FFBB0302BMOAOH3DAU VERTICAL CABINET 320 1750 .04 4.5 40 80 2 208/1 11.6 47x10x30 80 ! FLOOR 2 CUH-2 ' <br /> � ��;t aF . <br /> �..�,. <br /> NOTES: � <br /> 11 � <br /> 1. PROVIDE WITH INTERNAL THERMOSTAT AND WALL BRACKET. � <br /> 2. PROVIDE WITH INTERNAL THERMOSTAT. �y <br /> � ����� <br /> EXISTING ROOFTOP UNIT SCHEDULE <br /> MARK LOCATION AREA SERVED MANUFACTURER / MODEL NO. NEW SUPPLY VENT. MIN NOTES MARK <br /> AIR (CFM) OA(CFM <br /> RTU-1 ROOF TRAINING 213 TRANE Y4CC3042B 1540 200 1 RTU-1 ar�a REdSTERED <br /> ARCHITECT <br /> RTU-2 ROOF TRAINING 203 TRANE Y4CC3024B 1000 100 1 RTU-2 <br /> SMIDRA J. ALDER <br /> RTU-3 ROOF LOBBY 204 TRANE Y4CC3030C 110Q 200 1 RTU-3 ������� <br /> , ` <br /> RTU-4 ROOF ! WORKSTATION 211 TRANE Y4CC3048A 1750 350 1 RTU-4 <br /> SCALE: AS NOTED <br /> ISSUE DATE: 07/24/2017 � <br /> NOTEs: DRAWN: AC <br /> 1. PROVIDE SHEAVE/BELT CHANGES AS NECESSARY TO SUIT NEW AIRFLOW REQUIREMENTS. <br /> CHECKED: RE <br /> _ (� THIS PLAN AND DES'I(�V IS AND REMAINS <br /> THE PROPERTY OF THE ARCHITECTS AND <br /> MAY NOT BE USED NATHOUT PRIOR <br /> PIPING SYSTEMS INSULATION SCHEDULE DUCT SYSTEMS INSULATION SCHEDULE CONSENT FROM THE ARCHITECT <br /> TYPE OF PIPE INSTALLATION LOCATION INSULATION TYPE PIPE SIZE INCHES INSULATION THICKNESS INCHES NOTES LOCATION OF DUCT SYSTEM TYPE DUCT CONFIGURATION INSULATION TYPE MINIMUM R-VALUE, INSULATION NOTES <br /> DUCT THICKNESS REVIEW <br /> CO�D PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS ALL SIZES 1"THICK 1 <br /> RECTANGULAR - EXPOSED RIGID BOARD � R-7, 1 LAYER, 2 INCH THICK 1, 2 � <br /> 1-1/4 INCH AND SMALLER 1" THICK 1 DUCT NOT WITHIN REV. DATE DESCRIPTION <br /> HOT PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS CONDITIONED SUPPLY AND RETURN RECTANGULAR-CONCEAL�D DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 1, 2 <br /> 1-1/2 INCH AND LARGER 1-1/2"THICK 1 SPACE 05 26 SCHEMATIC DESIGN <br /> ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 1, 2 OS 'I 'rJ PROGRESS DRAWINGS <br /> NOTES: ' <br /> 1. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. RECTANGULAR - EXPOSED RIGID BOARD '� R-3.3, 1 INCH THICK 1, 2 O9 OS PERMIT SET <br /> DUCT WITHIN <br /> CONDITIONED SUPPLY RECTANGULAR - CONCEALED DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK 1, 2 <br /> SPACE � <br /> ROUND AND OVAL DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK 1, 2 <br /> NOTES: <br /> 1. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. <br /> 2. SUPPLY AIR DUCTWORK DOWNSTREAM OF THE AIR-TERMINAL UNITS SHALL HAVE 1"THICK INTERNAUACOUSTICAL M ECH AN I CAL SCH EDU LES <br /> DUCT LINING AS SPECIFIED FOR A MINIMUM OF 10 FEET LENGTH INCLUDING AN ELBOW. <br /> • <br /> � <br />