My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3001 OAKES AVE 2017 Plans 2022-11-23
>
Address Records
>
OAKES AVE
>
3001
>
Plans
>
3001 OAKES AVE 2017 Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 2:09:44 PM
Creation date
11/6/2019 10:55:31 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3001
Permit
B1709-011
Year
2017
Notes
RESTORATION OF EXTG INTERIOR WALLS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLUMBING FIXTURE SCHEDULE AIR DEVICE SCHEDULE <br /> CARNEGIE <br /> MARK FIXTURE TYPE AIRFLOW FRAME TYPE FINISH MATERIAL ACC. NOTES MARK B U I L D I N G - <br /> WASTE VENT RL ORL CW HW NOTES MARK MARK MANUFACTURER/MODEL NO. SUPPLY/ DESCRIPTION i TYPE NECK SIZE FACE SIZE SLOT <br /> (IN) (IN) (IN) (IN) (IN) (IN) RETURN / (BORDER TYPE) (LxV� (LxV1n QTY/WIDTH RANGE <br /> EXH �,N> �,N, �#„N, <25 NC R E S TO R A TI 0 N . <br /> L-1 LAV-COUNTER MOUNT 1-1/2" 1-1/2" - - 1/2" 1/2" NOTE 9 L-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 6" DIA 24x24 - 0 - 150 1 WHITE STEEL 4 WAY A JOO� OAK ES AVE. <br /> WC-1 WATER CLOSET � 4" 2" - - 1-1/4" - NOTE 2 WC-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 8" DIA 24x24 - 170 -220 1 WHITE STEEL 4 WAY A EVERETT, WA 982�1 <br /> UR-1 URINAL 2" 1-1/2" - - 1" - NOTE 2 UR-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 10" DIA 24x24 - 250 - 350 1 WHITE STEEL 4 WAY A <br /> i U �" <br /> DS-1 SINK- BREAKROOM 1-1/2" 1-1/2" - - 1J2" 1/2" NOTE 1 DS-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 12" DIA 24x24 - 375-475 1 WHITE STEEL 4 WAY A a <br /> � � <br /> DF-1 DRINKING FOUTAIN 2" 1-1/2" - - 1/2" - DF-1 A TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN 14" DIA 24x24 - 500-650 1 WHITE STEEL 4 WAY A � <br /> � <br /> MS-1 MOP SINK 3" 2" - - 3/4" 3/4" MS-1 , � , <br /> � � <br /> NOTES: B TITUS TMSA SUPPLY SQUARE CEILING DIFFUSER HARD OR LAY-IN PER PLANS 12x12 - 0 -450 1 WHITE STEEL 4 WAY B � <br /> A. PIPE SIZES LISTED MAY BE DIFFERENT THAN THE ACTUAL FIXTURE CONNECTION. PROVIDE BRANCH PIPE OF �ISTED �I <br /> SIZE AND ALL PIPE FITTINGS AND OFFSETS REQUIRED FOR COMPLETE iNSTALLATION. C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 10x10 12x12 UP TO 450 1 WHITE ALUMINUM PFA C � <br /> �--� <br /> .�..� <br /> B. PROVIDE FINAL CONNECTIONS TO ALL FIXTURES. � <br /> C. PROVIDE WALL CLEANOUTS FOR ALL SINKS, WATER CLOSETS, AND URINALS. C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x10 24x12 UP TO 700 1 WHITE ALUMINUM PFA C � <br /> C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x22 24x24 UP TO 1600 1 WHITE ALUMINUM PFA C U <br /> NOTES: - <br /> 1. PROVIDE INSTANTANEOUS ELECTRIC WATER HEATER AS NOTED ON DRAWINGS. C TITUS 50F RET/EXH EGGCRATE RETURN GRILLE HARD OR LAY-IN 22x46 24x48 UP TO 3000 1 WHITE ALUMINUM PFA c 2813 ROCKEFELLER AVE <br /> 2. ADA COMPLIANT WHERE INDICATED ON THE ARCHITECTURAL DRAWINGS. MOUNTING HEIGHT AS INDICATED EVERETT, WA 98201 � <br /> ON ARCHITECTURAL DRAWINGS. PHONE: 425.3'I 7.$O�7 <br /> D TITUS FLOWTEE SUPPLY LINEAR DIFFUSER W/ PLENUM HARD OR LAY-IN PER PLANS 48x10 PER PLANS 0-400 1 WHITE STEEL 1 WAY NOTE 1 o FAX: 425.3'I 7.8489 <br /> E TITUS 272RL SUPPLY SIDE WALL SUPPLY GRILLE HARD OR LAY-fN PER PLANS PER P�ANS - PER PLANS 1 WHITE STEEL 2 WAY E ` <br /> NOTES: <br /> 1. REFER TO PLANS FOR MODEL NUMBER, INLET SIZE, SIZE AND NUMBER OF SLOTS, ETC. PROVIDE FIELD-BUILT PLENUM TO SUIT AVAILABLE SPACE ABOVE CEILING. <br /> CABINET UNIT HEATER SCHEDULE <br /> MARK LOCATION AREA SERVED MANUFACTURER/MODEL NO. TYPE AIRFLOW FAN MOTOR EL.ECTRIC HEATING COIL ELECTRICAL PHYSICAL MOUNTING / NOTES MARK <br /> (CFM) RPM HP/WATTS TOTAL EAT LAT STAGES U�� AMPS LxWxH WEIGHT SUPPORT <br /> CAPACITY (DEG F) (DEG F) (#) (A) (INxINxIN) (LBS) � �, �,'' _ <br /> CUH-1 VESTIBULE 200 VESTIBULE 200 TRANE FFHB0302BMOCOC3BAU VERTICAL RECESSED 320 1750 .04 �4.5� 55 95 2 208/1 11.6 47x10x30 80 WALL 1 CUH-1 � �'�.,� <br /> � � �� � <br /> CUH-2 RISER ROOM 101 RISER ROOM 101 TRANE FFBB0302BMOAOH3DAU VERTICAL CABINET 320 1750 .04 4.5 40 80 2 208/1 11.6 47x10x30 80 ! FLOOR 2 CUH-2 ' <br /> � ��;t aF . <br /> �..�,. <br /> NOTES: � <br /> 11 � <br /> 1. PROVIDE WITH INTERNAL THERMOSTAT AND WALL BRACKET. � <br /> 2. PROVIDE WITH INTERNAL THERMOSTAT. �y <br /> � ����� <br /> EXISTING ROOFTOP UNIT SCHEDULE <br /> MARK LOCATION AREA SERVED MANUFACTURER / MODEL NO. NEW SUPPLY VENT. MIN NOTES MARK <br /> AIR (CFM) OA(CFM <br /> RTU-1 ROOF TRAINING 213 TRANE Y4CC3042B 1540 200 1 RTU-1 ar�a REdSTERED <br /> ARCHITECT <br /> RTU-2 ROOF TRAINING 203 TRANE Y4CC3024B 1000 100 1 RTU-2 <br /> SMIDRA J. ALDER <br /> RTU-3 ROOF LOBBY 204 TRANE Y4CC3030C 110Q 200 1 RTU-3 ������� <br /> , ` <br /> RTU-4 ROOF ! WORKSTATION 211 TRANE Y4CC3048A 1750 350 1 RTU-4 <br /> SCALE: AS NOTED <br /> ISSUE DATE: 07/24/2017 � <br /> NOTEs: DRAWN: AC <br /> 1. PROVIDE SHEAVE/BELT CHANGES AS NECESSARY TO SUIT NEW AIRFLOW REQUIREMENTS. <br /> CHECKED: RE <br /> _ (� THIS PLAN AND DES'I(�V IS AND REMAINS <br /> THE PROPERTY OF THE ARCHITECTS AND <br /> MAY NOT BE USED NATHOUT PRIOR <br /> PIPING SYSTEMS INSULATION SCHEDULE DUCT SYSTEMS INSULATION SCHEDULE CONSENT FROM THE ARCHITECT <br /> TYPE OF PIPE INSTALLATION LOCATION INSULATION TYPE PIPE SIZE INCHES INSULATION THICKNESS INCHES NOTES LOCATION OF DUCT SYSTEM TYPE DUCT CONFIGURATION INSULATION TYPE MINIMUM R-VALUE, INSULATION NOTES <br /> DUCT THICKNESS REVIEW <br /> CO�D PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS ALL SIZES 1"THICK 1 <br /> RECTANGULAR - EXPOSED RIGID BOARD � R-7, 1 LAYER, 2 INCH THICK 1, 2 � <br /> 1-1/4 INCH AND SMALLER 1" THICK 1 DUCT NOT WITHIN REV. DATE DESCRIPTION <br /> HOT PLUMBING PIPING INSIDE BUILDING ENVELOPE FIBERGLASS CONDITIONED SUPPLY AND RETURN RECTANGULAR-CONCEAL�D DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 1, 2 <br /> 1-1/2 INCH AND LARGER 1-1/2"THICK 1 SPACE 05 26 SCHEMATIC DESIGN <br /> ROUND AND OVAL DUCT WRAP R-7, 1 LAYER, 3 INCH THICK 1, 2 OS 'I 'rJ PROGRESS DRAWINGS <br /> NOTES: ' <br /> 1. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. RECTANGULAR - EXPOSED RIGID BOARD '� R-3.3, 1 INCH THICK 1, 2 O9 OS PERMIT SET <br /> DUCT WITHIN <br /> CONDITIONED SUPPLY RECTANGULAR - CONCEALED DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK 1, 2 <br /> SPACE � <br /> ROUND AND OVAL DUCT WRAP R-3.3, 1 LAYER, 1-1/2 INCH THICK 1, 2 <br /> NOTES: <br /> 1. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. <br /> 2. SUPPLY AIR DUCTWORK DOWNSTREAM OF THE AIR-TERMINAL UNITS SHALL HAVE 1"THICK INTERNAUACOUSTICAL M ECH AN I CAL SCH EDU LES <br /> DUCT LINING AS SPECIFIED FOR A MINIMUM OF 10 FEET LENGTH INCLUDING AN ELBOW. <br /> • <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.