My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3001 OAKES AVE 2017 Plans 2022-11-23
>
Address Records
>
OAKES AVE
>
3001
>
Plans
>
3001 OAKES AVE 2017 Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 2:09:44 PM
Creation date
11/6/2019 10:55:31 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3001
Permit
B1709-011
Year
2017
Notes
RESTORATION OF EXTG INTERIOR WALLS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> AIR HANDLING UNIT SCHEDULE <br /> CARN EGI E <br /> MARK LOCATION AREA SERVED MANUFACTURER/ MODEL NO. ENT. MI COIL MAX SUPPLY RETURN HEAT HEATING PREFILTER RETURN ELECTRICAL PHYSICAL MOUNTING/ NOTES MARK B U I L D i N G <br /> OA OA FAN MARK �AN MARK EX�HA�NK ER COIL MARK MARK PRMARKER MCA MOCP LxWxH WEIGHT SUPPORT ; R E S TO R A TI 0 N <br /> (CFM) (CFM) ' . <br /> (INxINxIN) (LBS) <br /> AHU-1 ROOF LOWER LEVEL DYNAMIC AIR D-AHU-2 1200 1200 SF-01 RF-01 HX-01 GF-01 PF-01 RPF-01 ' 25.2 30 140x66x42 2600 ROOF ' 1, 2 AHU-1 3001 OAKES AVE. <br /> EVERETT, WA 98201 <br /> NOTES: <br /> 1. EQUIPMENT SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATINGS. <br /> 2. UNIT COMPLIES WITH 2O15 WSEC SECTION C403.6 DOAS WITH HEAT RECOVERY REQUIREMENTS. U � � <br /> a <br /> � <br /> � <br /> � <br /> AHU PREFILTER SCHEDULE AHU SUPPLY FAN SCHEDULE � <br /> MARK ASSOCIATED PREFILTER NOTES MARK MARK ASSOCIATED SUPPLY FAN MOTOR NOTES MARK � <br /> UNIT TYPE MERV FACE VEL INITIAL PD FINAL PD QTY/SIZE UNIT TYPE � � <br /> MAX FLOW MIN FLOW TSP ESP RPM SPEED RPM BHP HP , TYPE V/Q1 <br /> RATING (FPM) (IN WC) (IN WC) (#)-(INxINxIN) (CFM) (CFM) (IN WC) (IN WC) � CONTROL � <br /> .� <br /> - AHU-1 CARTRIDGE 8 500 0.23 1.00 1-20x20x2 PF-01 SF-01 AHU-1 PLENUM 1200 1200 2.85 1.00 2411 ECM 1750 3.8 5 � ODP 208/3 SF-01 � <br /> CC� <br /> U <br /> 2813 ROCKEFELLER AVE <br /> AHU RETURN PREFILTER SCHEDULE AHU RETURN FAN SCHEDULE EVERETT, WA 98201 <br /> MARK ASSOCIATED RETURN PREFILTER NOTES MARK MARK ASSOCIATED RETURN FAN RETURN FAN MOTOR NOTES MARK PHONE: 42 'rJ.3�7.$O�7 <br /> UNIT TYPE MERV FACE VEL INITtAL PD FINAL PD QTY/SIZE UNIT TYPE MAX FLOW MIN FLOW TSP ESP RPM SPEED RPM BHP HP TYPE V/QJ FAX: 4Z 'rJ' .3�7.8489 <br /> RATING (FPM) (IN WC) (IN WC) (#)-(INxINxIN <br /> ) (CFM) (CFM) (IN WC) (IN WC) CONTROL <br /> RPF-01 ' AHU-1 CARTRIDGE 8 500 0.23 1 1-20x20x2 RPF-01 RF-01 AHU-1 PLENUM 1200 1200 2.75 1.00 2376 ECM 1750 3.8 5 ODP 208/3 RF-01 <br /> AHU HEAT EXCHANGER SCHEDULE - <br /> MARK ASSOCIATED HEAT EXCHANGER NOTES MARK <br /> UNIT TYPE SUPPLY EXHAUST MAX APD MAX FV W SA EAT W SA LAT W EA EAT W EA LAT WINTER EFF. " <br /> (CFM) (CFM) (IN WC) (FPM) (DEG F) (DEG F) (DEG F) (DEG F) (%) <br /> HX-01 AHU-1 PLATE 1200 1200 0.5 500 95 48 70 45 60.0 HX-01 <br /> �� ��� <br /> � �.t} <br /> AHU GAS-FIRED HEATING COIL � . " <br /> �� �.�� - <br /> MARK ASSOCIATED GASFURNACE NOTES MARK <br /> UNIT �NPUT(MBH) OUTPUT EAT LAT AFUE STAGES MAX APD FLUE DIA COMB AIR RUNOUT ��1� � . <br /> (MBH) (DEG F)(DEG F) (%) (#) (IN WC) (IN) (IN) GAS (DIA} A� ��' <br /> GF-01 AHU-1 50A 40 48 70 80 MOD. 0.3 5 5 3/4" 1 GF-01 <br /> � �� <br /> FAN SCHEDULE <br /> MARK LOCATION AREA SERVED MANUFACTURER/ MODEL NO. FAN TYPE qIRFLOW AIRFLOW ESP AN RPM FAN WHEEL FAN MOTOR SPEED BACKDRAFT PHYSICAL SOUND SOUND MOUNTING/ INTERLOCK INTERLOCK NOTES MARK <br /> MAX. (CFM) CURRENT (IN WG) TYPE SIZE (IN) DRIVE CLASS RPM HP V/f7� CONTROL DAMPTER AT DxH WEIGHT INLET LEVEL SUPPORT DIV 23 DIV 26 ario REqSTERED - <br /> (CFM) FAN <br /> (INxINxIN) (LBS) (SONES) �dgq� I1RCH11ECT <br /> EF-1 ATTIC GENERAL EXHAUST GREENHECK SQ-160HP-VG IN-LINE 1200 700 0.75 1031 BI 20 DIRECT I 1600 1 120 ECM Y 26x26x29 150 6.9 56 � HUNG Y N 1 EF-1 ��� � �� <br /> NOTES: ar��ai wu►�r�aroN <br /> 1. MOTOR CONTROLLER SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDiCATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATfNGS. <br /> SCALE: AS NOTED - <br /> ISSUE DATE: 07/24/2017 <br /> DRAWN: AC <br /> �HECKED: RE <br /> �EI PROPERTY OF THE� 'ARCHITECTSMAND <br /> MAY NOT BE USED WITHOUT PRIOR <br /> CONSENT fROM THE ARCHITECT <br /> REVIEW <br /> REV. DATE DESCRIPTION . <br /> �5 26 SCHEMATIC DESIGN <br /> 08 15 PROGRESS DRAWINGS <br /> 09 08 PERMIT SET <br /> MECHANICAL SCHEDULES <br /> . � <br />
The URL can be used to link to this page
Your browser does not support the video tag.