r <br /> AIR HANDLING UNIT SCHEDULE <br /> CARN EGI E <br /> MARK LOCATION AREA SERVED MANUFACTURER/ MODEL NO. ENT. MI COIL MAX SUPPLY RETURN HEAT HEATING PREFILTER RETURN ELECTRICAL PHYSICAL MOUNTING/ NOTES MARK B U I L D i N G <br /> OA OA FAN MARK �AN MARK EX�HA�NK ER COIL MARK MARK PRMARKER MCA MOCP LxWxH WEIGHT SUPPORT ; R E S TO R A TI 0 N <br /> (CFM) (CFM) ' . <br /> (INxINxIN) (LBS) <br /> AHU-1 ROOF LOWER LEVEL DYNAMIC AIR D-AHU-2 1200 1200 SF-01 RF-01 HX-01 GF-01 PF-01 RPF-01 ' 25.2 30 140x66x42 2600 ROOF ' 1, 2 AHU-1 3001 OAKES AVE. <br /> EVERETT, WA 98201 <br /> NOTES: <br /> 1. EQUIPMENT SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATINGS. <br /> 2. UNIT COMPLIES WITH 2O15 WSEC SECTION C403.6 DOAS WITH HEAT RECOVERY REQUIREMENTS. U � � <br /> a <br /> � <br /> � <br /> � <br /> AHU PREFILTER SCHEDULE AHU SUPPLY FAN SCHEDULE � <br /> MARK ASSOCIATED PREFILTER NOTES MARK MARK ASSOCIATED SUPPLY FAN MOTOR NOTES MARK � <br /> UNIT TYPE MERV FACE VEL INITIAL PD FINAL PD QTY/SIZE UNIT TYPE � � <br /> MAX FLOW MIN FLOW TSP ESP RPM SPEED RPM BHP HP , TYPE V/Q1 <br /> RATING (FPM) (IN WC) (IN WC) (#)-(INxINxIN) (CFM) (CFM) (IN WC) (IN WC) � CONTROL � <br /> .� <br /> - AHU-1 CARTRIDGE 8 500 0.23 1.00 1-20x20x2 PF-01 SF-01 AHU-1 PLENUM 1200 1200 2.85 1.00 2411 ECM 1750 3.8 5 � ODP 208/3 SF-01 � <br /> CC� <br /> U <br /> 2813 ROCKEFELLER AVE <br /> AHU RETURN PREFILTER SCHEDULE AHU RETURN FAN SCHEDULE EVERETT, WA 98201 <br /> MARK ASSOCIATED RETURN PREFILTER NOTES MARK MARK ASSOCIATED RETURN FAN RETURN FAN MOTOR NOTES MARK PHONE: 42 'rJ.3�7.$O�7 <br /> UNIT TYPE MERV FACE VEL INITtAL PD FINAL PD QTY/SIZE UNIT TYPE MAX FLOW MIN FLOW TSP ESP RPM SPEED RPM BHP HP TYPE V/QJ FAX: 4Z 'rJ' .3�7.8489 <br /> RATING (FPM) (IN WC) (IN WC) (#)-(INxINxIN <br /> ) (CFM) (CFM) (IN WC) (IN WC) CONTROL <br /> RPF-01 ' AHU-1 CARTRIDGE 8 500 0.23 1 1-20x20x2 RPF-01 RF-01 AHU-1 PLENUM 1200 1200 2.75 1.00 2376 ECM 1750 3.8 5 ODP 208/3 RF-01 <br /> AHU HEAT EXCHANGER SCHEDULE - <br /> MARK ASSOCIATED HEAT EXCHANGER NOTES MARK <br /> UNIT TYPE SUPPLY EXHAUST MAX APD MAX FV W SA EAT W SA LAT W EA EAT W EA LAT WINTER EFF. " <br /> (CFM) (CFM) (IN WC) (FPM) (DEG F) (DEG F) (DEG F) (DEG F) (%) <br /> HX-01 AHU-1 PLATE 1200 1200 0.5 500 95 48 70 45 60.0 HX-01 <br /> �� ��� <br /> � �.t} <br /> AHU GAS-FIRED HEATING COIL � . " <br /> �� �.�� - <br /> MARK ASSOCIATED GASFURNACE NOTES MARK <br /> UNIT �NPUT(MBH) OUTPUT EAT LAT AFUE STAGES MAX APD FLUE DIA COMB AIR RUNOUT ��1� � . <br /> (MBH) (DEG F)(DEG F) (%) (#) (IN WC) (IN) (IN) GAS (DIA} A� ��' <br /> GF-01 AHU-1 50A 40 48 70 80 MOD. 0.3 5 5 3/4" 1 GF-01 <br /> � �� <br /> FAN SCHEDULE <br /> MARK LOCATION AREA SERVED MANUFACTURER/ MODEL NO. FAN TYPE qIRFLOW AIRFLOW ESP AN RPM FAN WHEEL FAN MOTOR SPEED BACKDRAFT PHYSICAL SOUND SOUND MOUNTING/ INTERLOCK INTERLOCK NOTES MARK <br /> MAX. (CFM) CURRENT (IN WG) TYPE SIZE (IN) DRIVE CLASS RPM HP V/f7� CONTROL DAMPTER AT DxH WEIGHT INLET LEVEL SUPPORT DIV 23 DIV 26 ario REqSTERED - <br /> (CFM) FAN <br /> (INxINxIN) (LBS) (SONES) �dgq� I1RCH11ECT <br /> EF-1 ATTIC GENERAL EXHAUST GREENHECK SQ-160HP-VG IN-LINE 1200 700 0.75 1031 BI 20 DIRECT I 1600 1 120 ECM Y 26x26x29 150 6.9 56 � HUNG Y N 1 EF-1 ��� � �� <br /> NOTES: ar��ai wu►�r�aroN <br /> 1. MOTOR CONTROLLER SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDiCATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATfNGS. <br /> SCALE: AS NOTED - <br /> ISSUE DATE: 07/24/2017 <br /> DRAWN: AC <br /> �HECKED: RE <br /> �EI PROPERTY OF THE� 'ARCHITECTSMAND <br /> MAY NOT BE USED WITHOUT PRIOR <br /> CONSENT fROM THE ARCHITECT <br /> REVIEW <br /> REV. DATE DESCRIPTION . <br /> �5 26 SCHEMATIC DESIGN <br /> 08 15 PROGRESS DRAWINGS <br /> 09 08 PERMIT SET <br /> MECHANICAL SCHEDULES <br /> . � <br />