3927 RUCKER AVE 2018 Plans 2022-12-02
>
Address Records
>
RUCKER AVE
>
3927
>
Plans
>
3927 RUCKER AVE 2018 Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 10:37:34 AM
Creation date
11/6/2019 11:43:19 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Permit
B1804-013
Year
2018
Notes
REPLACE BLDG CLADDING EXTEND EXISTING ADD NEW ENTRY CANPOY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�. <br /> I � A2-02 � — — � — — — — — — — — — — — — — �� <br /> — — — + — — — — — — — — — — — — — — — — — — — — — — - — — — — — ���� � ��������� <br /> I � � � � � I � � � } `�`" �` (;� . <br /> � �::,�` � �� � � 1 �� 1 � �1� � <br /> I � � <br /> ( <br /> � ( I � � I � � � I I <br /> � , I <br /> � - ' - E8 <br /> - , - - - - - - - - i <br /> � � � � i � � � � : <br /> ' I "`PROJECT NOTES� . <br /> � <br /> � 1. Remove e�osting coping-instail new coping and snap lock I <br /> I I I � flashing per detail-typical at all sides of the building unless noted I I � ( <br /> � otherwise � <br /> 2. Area of reduced parapet height(5"appro�amate clr ht)apply new <br /> �� I coping per detail <br /> wl 3 3. F�dsting coping at entry curtain wall glazing to remain-tie to new <br /> coping per detail � <br /> I � I 4. � Low roof beyond-prep and install new roof overlay-material to � � � � <br /> match existing system-verify carlisle epdm with decorative � G V N D E R�O � � <br /> � ballast, coping and associated wall flashings per details <br /> 5. Existing entry canopy beyond-basic scope-remove existing I <br /> Kalwall and store for re-use.As necessary to install the new , <br /> I I I work-Cut and remove 1 ex isting sloped frame against the I �i� � BASIC WORK-EIFS CLADDING � I 6 V ' L D ' N� � <br /> exterior wall-Re-assemble and reinstall following cladding work. - -- <br /> _ � _ _ _ _ _ _Substitute new AEP span Select seam narrow batten roofing ���-�-�_� I _ A.- -Remove existing cladding(including stone plinths — — — — D$ ' <br /> — — — — — � anels for existin corru ated metal roofin anels t���-��� <br /> P 9 9 9 P as several locations around the building.}and � R E C LA D <br /> 6. New sloped sill-AEP Span ftush metal or Select Seam Narrow � , __.,�� _t_$_ , sheathing to expose e�sting framing and 6"batt <br /> -,_ <br /> Sill- Batten panels-carry tight to exterior wall(with windows)tuck -:�TM � insulation. � <br /> I below existing window sill flashing-extend as necessary.Carry � _ B� ` ���� ` � B. Install new 5/8"Dens Glas Gold sheathing and ( <br /> � ( � projected sill across intermediate columns at contiguous recessed � �� A �-.. / ' � <br /> --�,�,_� , approved wet applied wrb materials(same as at <br /> I window conditions-Continuous head flashing at the top of - � "�-- ,�,g ' eifs) � � <br /> contiguous window recesses placed at intersection of soffit and � �. , �:f '$� � ���� C. Install new AEP Span Select Seam standing seam 3927 Rucker Ave, Everett� Wa <br /> � furthest exterior walt. Typical at all recessed window locations. �.`-�--? ' � ' metal anel claddin assume 20"wide anels, <br /> 7. Existin bus sto tem oraril remove exisitin railin reinstall `` tl�`' � � � � � p g p <br /> 9 p- P Y 9 9- I D � '-�. If �}'; F �� � centered-run continuous across all contiguous � <br /> I � � following completion of the work in that area. Coordinate with ! � , �, window recesses. I I <br /> Community Transit. B� �� � � �� �� D. Install new Dryvit Outsulation MD system in <br /> 8. E�ccavate along builidng-6-12"down 8"min from bldg-place "'�-,� = a '1 � ���' " - <br /> .� � � i �.��n; thicknesses noted on the drawings- <br /> � retaining mtls per detail,drain pipe and drain rock to maintain �'� �--``� ��� r,_ • Refer to Dryvit details OPMD 0,0,01,02 <br /> separation from bottom of cladding to grade.Tie to e�asting �''�-4 ' � , �, �; and 06/A3-02 for typical manufacturer's <br /> � footing drain-Altemately pravide 12°diameter drywell2'deep in ' �` �� - details � A2-01 . <br /> j A2 02 i Z I � � landscaping.Det 02/A3-01.b � � � I�" � • assume two finish colors- ( � <br /> ' I , a. Minor ad justment of e�stin g grade at buildin g to create • I n s t a l l p r e c a s t c o n c r e t e a c c e n t p a n e l s a t <br /> r drainage swale at area indicated to the south side of the � the three building entrances as indicated. <br /> — — — — — — � building. — — — — — � — — — — � — — — — — D'� <br /> � 9. � Typical recladdin work betow existing curtain wall element. <br /> 10. i coo ' es a ensi ' to r ' pera'onal � <br /> ( � � during all constructio activities. lash existing sheet met cover � BAS1C RECLADDING WORK I I I <br /> with new sheet metal flashing per detail 04/A3-01 b 1/4�� - 1�-��� <br /> ; I 11. Temporarily remove exisitng canvas canopy at 1st flr East si e- <br /> i Reinstall at completion of work � <br /> _ j _ _ _ _ _ � _ _ _ _ _ 12 _Sign Location-confirm location of mounting points for the _ _ _ _ _ _ _ _ — �_ — — — — _ ('�G , , <br /> e�sting sign to be reinstalled-coordinate with owner. Trea vJ 04 25 18 <br /> ._ � I � � � mounting points in conformance with Dryvit details. I "EIFS"NOTE � � <br /> 13. Own t onfirm e 'ment s' e d rou ning r ' ed for � For Construction <br /> ceme . Ve t wall ' g is fr to this Use of the EIFS label on these drawings relates directly to the • <br /> , I criteria, and modify as required to conform if not,This minimally specified Dryvit system:Outsulation Plus MD System. The details <br /> requires a head track at the top and double studs at the jambs of contained on sheets A3-02,A3-03 and A3-04 are the manufacturer's <br /> the required opening. standard detaits for a wide range of conditions that exist at the I <br /> �', I I 14. I Continuous metal flashing at transition from 4"to 2"rigid I Gunderson building. These details illustrate the typical application <br /> ', ' � insufation aligned with the bottom sill condition of the first floor and installation requirements for the specified product. Other project <br /> windows. Typical-refer to detail A3-01 a specific details or scope notes that may conflict with the requirements ��� �����-����� <br /> 15 Contino eal ali ith the ashing 'ions at of these standard details will be brought to the attention of the <br /> _ _ _ _ _ _ _ _ _ _ _ _ reces o the 2n rd floo detail 0 - 1a _ Architect for clarification and resolution. --I— — — — — — — — — — B9 �;��i�"'���'��;T <br /> 16. Paint concrete sidewalls and rails at level landing to e�asting I I _ <br /> � � I � garage and the curved connecting stair. � <br /> 17. P int all exteri r hollow met I doors in are s of new EIFS to <br /> � � tch ne colors i I EIFS NOTE - <br /> � <br /> ' 1/4" = 1'-0" <br /> I 1� *Project notes are referenced from multiple drawings in this � , <br /> I ( I I drawing set � I I �,�) �� '�. 1���..�� <br /> I � �fi�TE �� "�''�hill'�l�fi��1 <br /> - - - - - ! - - - - - ! - - - - - - - - - - - - - - - - B4 <br /> � <br /> i I i i I i i � <br /> ► ► <br /> � <br /> � i .. <br /> � i i i I i � i . <br /> I rev-1 - date-topic addendum 1 -05 0918 <br /> — — — — — — � — — — — — � — — — — — — — — — — — — A7 rev-2-date-topic . <br /> I � <br /> I I � I I I � rev-3 - date-topic <br /> I I S���- rev-4-date- topic <br /> 01 <br /> I I 3-01 rev-5-date- topic <br /> I I � I I � I I I <br /> rev-6-date-topic <br /> - - - - � - - - - - A1 � <br /> � i � i i i i � . <br /> i i i i � i i i <br /> � <br /> 8 7 6 5 4 3 2 1 <br /> 2 <br /> A2-01 � <br /> THIRD FLOOR PLAN <br /> � LEVEL 3 �� <br /> , 1/8 = 1 0 ; <br /> , <br /> I - <br /> � <br /> ; EVOLUTION � <br /> i ARCHITECTURE - INC <br /> 6264 ELLIS AVE S , . <br /> Seattle, Washington, _ <br /> ph 206 588 <br /> I info@evolutionarchitecture.net ' <br /> � <br />