My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20 SW EVERETT MALL WAY Geotech Report 2018-01-02 MF Import
>
Address Records
>
SW EVERETT MALL WAY
>
20
>
Geotech Report
>
20 SW EVERETT MALL WAY Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:57:23 AM
Creation date
11/18/2019 7:58:25 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
20
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Campbell-Fleury Investments/Mallwest Center <br />9 April 1986 <br />W-3103-1 <br />Page 7 <br />_ 4.3 Shallow Foundations <br />The structures may be supported by conventional shallow spread footings, continuous <br />wall footings, or extended footings. If the structure is to be founded on structural <br />fill after total removal of the fill and relic topsoil, conventional spread footings <br />and/or continuous wall footing, may be used. Al1 existing uncontrolled fill and <br />organic native soiis beneath any footings should be removed and replaced with <br />structural fill. The extent of structural fill beneath any footing should begin <br />- at least 1 foot frum the edge of the footing and slope downward and outward from <br />the footing at an angle no steeper than 1H:1V (Horizontal:Vertical) to suitable <br />_ undisturbed natural bearing soils. This would result in a compacted wedge of <br />structural fill beneath the footing and on which stresses of the footing wi11 be <br />carried, <br />If uncontrolled fill soi',s are to remain, the structure should be directly founded <br />on suitable undisturbed, natural bearing soils utilizing extended spread footings <br />to bring the foundation up to grade. <br />All footings should have a minimum width of at least 12 inches. The base of the <br />exterior footing should be located at least 18 inches below the lowest adjacent <br />ground surface or top of floor slab, whichever is lower. The interior footings <br />need only extend 12 inches below the lowest surrounding grade or slab surface. For <br />foundation elements founded on native soils or structural fill, we recommend that <br />the footings be designed with a maximum allowable bearing pressure of 2500 pounds <br />per square foot (psf). This allowable bearing pressure may be increased by up to <br />one-third to accommodate seismic or transient loads. All footings must penetrate <br />into the prescribed bearing stratum and the foundatior should not be set in or above <br />loose or disturbed soils, organic soils, or any existiny fill. <br />�-. Assuming that foundation elements are founded on the prescribed bearing stratum, <br />we anticipate that total settlements should be less than 1 inch with differential <br />,� settlements on the order of one-half of tnat total. However, if disturbed or soft <br />materials are left in the footing area prior to concrete placement, the settlements <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.