Laserfiche WebLink
/ <br /> . � <br /> Proposed Modernization and Addirions tn Subsurface Fxplorruion, Geolagic Hazards, <br /> Eisenhower Middle Schoof and Geotechnica[Engineering Report <br /> Everett, Washington DesiRn Recommendatinns <br /> A representative from our firm should inspect the stripped/overexcavated subgrade and be <br /> present during placement of structural fill to observe the work and perform a representative <br /> number of in-place densiry tests. In this way, the adequacy of the earthwork may be evaluated <br /> as filling progresses and any problem areas may be wrrected at that tune. It is :mportant to <br /> understand that taking random compaction tests on a part-time basis will not assure uniformity <br /> or acceptable performance of a fill. As such, we are available to aid the owner in developing a <br /> suitable monitoring and testing program. <br /> 10.0 FOUNDATIONS <br /> Our explorations indicate that the foundation bearing stra[um, consisting of inedium dense to <br /> very dense till underiies the proposed buil j.ing area at depths ranging from approximately 0 to <br /> 7 fee[. Where suitable bearing stratum is shallow, conventional spread footings may be us;.d. <br /> If the existing fill is shallow, the fill can be recompacted Co a firm and unyielding condition and <br /> used for foundarion support. In those area� where the fill is deep or where space limitations or <br /> economic considerations make excavation to [he foundation bearing stratum impractical, we <br /> recommend the n;e of a deepened foundation system for foundation support. Jeotechnical <br /> design recommendatioas for conventional spread footin,� foundations, driven pipe piles, and <br /> GeopiersT"' or rock trenches are presen[ed belc�w. <br /> i0.1 Conventional Spread Footines <br /> Spread footings may be used for building support when founded on suitable native till, <br /> recompacted existing fill, or new structural fill placed as previously discussed. To limit <br /> differential setdements betwc,:n footings that bear on scructural ii;l and those on dense till, we <br /> recommend that an allowable foundation soil bearing pressure of 3,000 pounds per square foot <br /> (ps� be utilized for design purposes, including both dead and live loads. If higher bearing <br /> pressures are needed, a value of 5,000 psf may be used in areas where all footings are placed <br /> entirely on dense till. An increase of one-third may be used for short-terni wind or seismic <br /> loading. Perimeter footings should be buried at least 18 inches into the surrounding soil for � <br /> frost protection; interior footings require only 12 inches burial. However, all footings must <br /> penetrate to the prescribed bearing s[ratum and no footing should be founded in or above <br /> loose, organic, or existing fill soils. <br /> [t should be noted that the area bounded by lines extending downward at 1H:1V from any <br /> footin, must not intersect another footing er intersect a filled area which has not been <br /> compac:ed to at least 9� percent of ASTM:D 1557. In addition, a 1.SH:1V line extending <br /> down from any foo[ine must not daylieht because sloughing or raveling may eventually <br /> undermine the footing. 1'hus, footines should nut be placed near [he edge of steps or cuts in <br /> the bearing suils. <br /> Jmiunrr•?3, ZOOd ASSOClA7'ED E,IR7'f!SGENCES, LYC. <br /> ,tlT�d-REOJ:�faJ-Prt;•rttsi]2);'Jy'�ti�ItC!'-IY.K Page 14 i7 <br />