My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 25TH AVE SE Geotech Report 2018-01-02 MF Import
>
Address Records
>
25TH AVE SE
>
10200
>
Geotech Report
>
10200 25TH AVE SE Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:01:31 PM
Creation date
12/12/2019 2:24:16 PM
Metadata
Fields
Template:
Address Document
Street Name
25TH AVE SE
Street Number
10200
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ <br /> . � <br /> Proposed Modernization and Addirions tn Subsurface Fxplorruion, Geolagic Hazards, <br /> Eisenhower Middle Schoof and Geotechnica[Engineering Report <br /> Everett, Washington DesiRn Recommendatinns <br /> A representative from our firm should inspect the stripped/overexcavated subgrade and be <br /> present during placement of structural fill to observe the work and perform a representative <br /> number of in-place densiry tests. In this way, the adequacy of the earthwork may be evaluated <br /> as filling progresses and any problem areas may be wrrected at that tune. It is :mportant to <br /> understand that taking random compaction tests on a part-time basis will not assure uniformity <br /> or acceptable performance of a fill. As such, we are available to aid the owner in developing a <br /> suitable monitoring and testing program. <br /> 10.0 FOUNDATIONS <br /> Our explorations indicate that the foundation bearing stra[um, consisting of inedium dense to <br /> very dense till underiies the proposed buil j.ing area at depths ranging from approximately 0 to <br /> 7 fee[. Where suitable bearing stratum is shallow, conventional spread footings may be us;.d. <br /> If the existing fill is shallow, the fill can be recompacted Co a firm and unyielding condition and <br /> used for foundarion support. In those area� where the fill is deep or where space limitations or <br /> economic considerations make excavation to [he foundation bearing stratum impractical, we <br /> recommend the n;e of a deepened foundation system for foundation support. Jeotechnical <br /> design recommendatioas for conventional spread footin,� foundations, driven pipe piles, and <br /> GeopiersT"' or rock trenches are presen[ed belc�w. <br /> i0.1 Conventional Spread Footines <br /> Spread footings may be used for building support when founded on suitable native till, <br /> recompacted existing fill, or new structural fill placed as previously discussed. To limit <br /> differential setdements betwc,:n footings that bear on scructural ii;l and those on dense till, we <br /> recommend that an allowable foundation soil bearing pressure of 3,000 pounds per square foot <br /> (ps� be utilized for design purposes, including both dead and live loads. If higher bearing <br /> pressures are needed, a value of 5,000 psf may be used in areas where all footings are placed <br /> entirely on dense till. An increase of one-third may be used for short-terni wind or seismic <br /> loading. Perimeter footings should be buried at least 18 inches into the surrounding soil for � <br /> frost protection; interior footings require only 12 inches burial. However, all footings must <br /> penetrate to the prescribed bearing s[ratum and no footing should be founded in or above <br /> loose, organic, or existing fill soils. <br /> [t should be noted that the area bounded by lines extending downward at 1H:1V from any <br /> footin, must not intersect another footing er intersect a filled area which has not been <br /> compac:ed to at least 9� percent of ASTM:D 1557. In addition, a 1.SH:1V line extending <br /> down from any foo[ine must not daylieht because sloughing or raveling may eventually <br /> undermine the footing. 1'hus, footines should nut be placed near [he edge of steps or cuts in <br /> the bearing suils. <br /> Jmiunrr•?3, ZOOd ASSOClA7'ED E,IR7'f!SGENCES, LYC. <br /> ,tlT�d-REOJ:�faJ-Prt;•rttsi]2);'Jy'�ti�ItC!'-IY.K Page 14 i7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.