Page 3 <br /> November 18, 2019 <br /> City of Everett, Public Works—Water Treatment Plant, Emergency Generator Replacement <br /> Contract Amendment—Professional Architectural and Engineering Services <br /> E. Mechanical Engineering: <br /> 1. Heating,ventilating, and exhaust system design, in compliance with minimum <br /> requirements of IBC, IMC, UPC,WAC, State of Washington Energy Code. <br /> 2. Plumbing: Plumbing design, cold water, building drainage systems, and roof <br /> drainage system. <br /> 3. Fire Suppression System; performance specifications. <br /> 4. Generator set fuel storage, piping,fuel polishing and pumping system,with leak <br /> detection. <br /> 5. Generator set cooling and exhaust. <br /> 6. Construction cost estimating assistance. <br /> F. Electrical Engineering: <br /> 1. Generator Plant: A complete electrical energy facility will be designed with <br /> generators and switchgear to meet the following objectives. The generators will <br /> be sized to support current site demand loads with N+1 redundancy plus addition <br /> of a future generator, and capable of independent operation in the event utility <br /> power is unavailable for extended periods. The main switchgear will provide <br /> utility connection, paralleling control of installed and future permanent <br /> generators, distribution to existing site transformers, and outdoor switchboards <br /> for connecting temporary generators at transformer secondaries. The switchgear <br /> design will be modular and maintainable without site shutdown or exposure to <br /> excessive arc flash risk. The existing 480volt generators and their paralleling <br /> equipment will be removed after the new generator plant is in service. The <br /> existing utility recloser replaced and connection to Portal 2 modified as <br /> coordinated with the serving utility. <br /> Site Distribution: A new underground site distribution system will be designed to <br /> provide power to the existing transformers. The distribution system will be <br /> designed for maintainability with limited impact to site operations. <br /> 2. Included in the work is an upgrade to following Motor Control Centers; <br /> MCC HFB/HFBG, replace both MCCs with single panelboard with discrete <br /> starters as required. <br /> MCC HFWPS/HFWPSG, replace both MCCs with single MCC or <br /> panelboard. Finish Water Pump#3 (250hp) starter will be replaced with VFD. <br /> MCC HW/HWGA, replace both MCCs with single unit. Two soft start and two <br /> line starters will be provided. Existing plug-based pump selection cabinet will be <br /> removed. <br />