My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5505 EVERGREEN WAY PRECISION COLLISION 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
5505
>
PRECISION COLLISION
>
5505 EVERGREEN WAY PRECISION COLLISION 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2020 9:42:43 AM
Creation date
1/28/2020 3:23:40 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5505
Tenant Name
PRECISION COLLISION
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12. The International Fire Code requires that all new structures shall provide Fire Department access roads <br /> tc within 150 feet exterior walking distance of all portions of the ground floor. Fire Department access <br /> roads (Fire Lanes) shall provide a minimum of 20 feet in width of unobstructed, paved driving surface <br /> with a minin�um clear height of 13'6". Inside tum radii must be 35 feet. Slope approach and departure <br /> angles must not exceed 10 degrees. Fire la;�e grade must not exceed 15 percent. Fire lane <br /> construction must comply wilh AASHTO ti3J load capacity. Fire Lanes will be posted and maintained <br /> as required by the Fire Department. UnoRiiodox access which meets code requirements but is too <br /> unusual for crews will not be aliowed. <br /> 13. When access to or wilhin a structure or an area is unduly difficult because of secured openings or where <br /> immediate access is r.ecessary for life saving or(ire-figl�ting purposes, the Fire Department may <br /> recommend or require a key box to be installed in an accessible location. A rapid entry system may <br /> also be desireble in order to avoid unnecessary damage whil� rr;�king entry to any buiiding during an <br /> emergency siluation. <br /> Please call (425) 257-81?_3 for further information. <br /> 14. A Knox Box is required. <br /> 15. Fire apparatus access roads shall be marked whene�ier necessary to maintain lhe unobstructed <br /> ml,�imum required width of readways. Fire lanes shall be marked as follows: <br /> a. Curbs shail he identified by red traffic paint with a 6-inch w•ide stripe on the top and front, extending <br /> the length o(lhe designated fire lane. <br /> b. Rolled curbs shall be identified by red traf(ic paint with a 6-inch wide stripe on the curb, extending <br /> the length of the designated fire lane. <br /> c. Lanes without curbs shail be identified by red tra`fic paint wilh a 6-inch wide stripe on the pavement, <br /> extending the length of lhe designaled fire lane. <br /> d. The words 'NO PARKING - FIRE LANE' shall be in 3-inch slroke white letters 18 inches in he;�ht, <br /> and placed 8 inches measured perpendicular from the red paint stripe on the pavement. In most <br /> cases, both sides of the access road shall be marked. Where lor�g drives are to be marked, lhe <br /> repetitions sl�all alternate sides of the drive. <br /> e. Marking shall also include the addition of inetal signs stating 'NO PARKING - FIRE LANE-TOW <br /> AWAY ZONG' to be installed at inlervals or locations designated by the Fire Code Official. The signs <br /> shall be approximately 12 inches in width and 18 inches in height and have red letters on a white <br /> background. Metal signs shall be installed on either 2-inch metal pipes for private property or <br /> treated 4-inch by A-inch wood posts for public property and shall be localed so that the bottom of the <br /> sign is a minimum of 7 feet above the curb. Where fire lanes aro adjacent to buildings or strvctures <br /> and when approved or direcled by lhe Fire Code Official, the signs may be placed on the face of the <br /> building or structure. <br /> f. Where directed by the Fire Code O(fcial, specific areas shall be designated and those areas are to <br /> be marked with diagonal striping across the width of the fire lane. Diagonal marking shall be used in <br /> conjunction with painted curbs ancllor edge striping and shall run at an angle of 30 te GO degrees <br /> (rom one side to the other. These diagonal lines shall be in red fraf(ic paint, parallel with each other, <br /> al least 6 inches in width and 24 inches apart. Leltering shall appear as above. <br /> 16. Fire ilow for this project is 1,500 gpm. <br /> 17.A portable fre extinguisher wilh a minimum U.L. raling of 2-A:10-B:C shall be provided within 75 feet of <br /> travel on all floors of each building during construclion and prior to occupancy. <br /> / <br /> `�S <br />
The URL can be used to link to this page
Your browser does not support the video tag.