My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
>
Address Records
>
EVERETT AVE
>
3007
>
GLOBODYNE INDUSTRIES
>
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 1:59:00 PM
Creation date
2/6/2020 1:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
3007
Tenant Name
GLOBODYNE INDUSTRIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Brian Bodge <br /> Plan Check Number: B1901-029, First Building Review <br /> March 6, 2019 <br /> Structural <br /> 1. Structural and geotechnical special inspections are required for this project. A statement on <br /> special inspections has not been provided and shall be submitted with the permit <br /> documents. The statement shall include a table listing each type of special inspection and <br /> shall specify the extent of each inspection (e.g., continuous, periodic) per IBC Section <br /> 1704.3.1. Special inspections may include, but are not limited to: soil inspections per Table <br /> 1705.6; concrete foundations, stairs, and post-installed anchors (i.e., stair handrails) per <br /> Table 1705.3; and masonry per Section 1705.4. See IBC Sections 107.1, 1704.2.3 and <br /> 1704.3. <br /> 2. The construction drawings include work that has been deferred by the designer. A <br /> statement of deferred submittals shall be added to the construction drawings listing work <br /> designated as deferred submittals. The note shall include a statement requiring the <br /> designer-of-record to review the deferred submittals and verify conformance with the <br /> construction documents. See IBC Sections 107.2.1, 107.3.4, 107.3.4.1, and 107.4. The <br /> following is a summary based on a review of the construction documents: <br /> a. Door awning per Elevation 1/A-2.0. <br /> 3. Elevation 1/A-2.0 includes an awning attached to the existing wall. The design of the <br /> awning and the connections have been deferred by the designer-of-record to the <br /> manufacturer. The construction drawings shall specify design criteria for the design of the <br /> awning and connections to the existing wall. The drawings shall specify wind pressures <br /> including uplift on the awing, and connection loads to the wall. A diagram shall be included <br /> in the construction drawings depicting the design loads. Loads shall be determine in <br /> accordance with ASCE 7-10 Chapter 30. See IBC Sections 1603.1.8 and 1609.1. <br /> 4. Partial Plan 1/A-3.0 shows a new retaining wall adjacent to the stairs. The following <br /> comments shall be addressed: <br /> a. The wall design does not appear to be complete. Missing information includes but is not <br /> limited to: material requirements for the CMU blocks, grout, and reinforcement; rebar <br /> vertical and horizontal spacing; and foundations. See IBC Sections 107.2.1 and 1603.1. <br /> b. Structural calculations for the design of the wall shall be submitted for review. The wall <br /> is located adjacent to parking spaces and must support vehicle surcharge loads in <br /> addition to active and seismic surcharge pressures. See IBC Sections 1604.1, 1605.1.1, <br /> 1605.2, 1610.1, and 1807.2. <br /> 5. The handrail in Section A-A/A-3.0, including the base connections, shall be design for the <br /> loads per IBC Section 1607.8. Calculations substantiating the design shall be submitted for <br /> review. Additional detailing for the handrails, including but not limited to the post base <br /> plates and welding, and post maximum spacing, shall be specified in the drawings. Note <br /> that Section A-A appears to only require connections at the top and bottom post; the <br /> intended construction shall be reviewed and revised as needed. See IBC Sections 107.2.1, <br /> 1603.1, and 1604.1. <br /> 0 3200 Cedar Street CD425.257.8800 O everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.