My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
>
Address Records
>
EVERETT AVE
>
3007
>
GLOBODYNE INDUSTRIES
>
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 1:59:00 PM
Creation date
2/6/2020 1:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
3007
Tenant Name
GLOBODYNE INDUSTRIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Drew Martin <br /> Plan Check Number: B1901-029, First Building Review Letter Response <br /> April 30, 2019 <br /> Accessibility: <br /> 6. The project involves Level 2 Alterations to the building per IEBC Chapter 8, Accessibility <br /> improvements per IEBC Section 7052 shall be included in the project. Potentially <br /> inaccessible elements include, but are not limited to, the bathrooms, stairs, ramps, entryway <br /> doors, and parking. Where the building is made to be less than fully-accessible per one of <br /> the exceptions, documentation substantiating the limited accessibility improvements shall be <br /> submitted for review. See IEBC Section 806.1. <br /> Response: <br /> A new accessible restroom is proposed, a new interior ramp is proposed to provide required <br /> accessibility at entry door. Additional dimensions and information on the existing ramp, landing <br /> and handrails have been added to the drawings. See sheets A-0.1, A-1.1 &A-1.2. The existing <br /> van accessible parking space is reflected on sheet C-1.0. <br /> 7 SheetA-1.1 specifies installation of new Door D1O2, The doorway and exterior landing shall <br /> be modified to provide the required maneuvering clearance per ICC A117.1-09 Section <br /> 404,23.2 and Figure 404.2.3.2(f); the Door Schedule shall state in the notes that a door <br /> closer shall not be provided unless a minimum 54-inch width is provided. Alternatively, the <br /> door swing may be reversed to provide the maneuvering clearance per Figure 4O4.2.3.2(g); <br /> the door loser shall similarly not be provided. See IEBC Sections 806.1 and 705.1, and IBC <br /> Section 1101.2, <br /> Response: <br /> Dimensions have been added for the exterior landing to clarify existing conditions, maneuvering <br /> clearance has been called out. No door closer will be provided, note has been added. See sheet <br /> A1.1 DOOR & HARDWARE NOTES. <br /> 8. The Basement Floor Plan throughout the construction drawings indicates that the ramp does <br /> not include extensions of the northeast and southwest ramp handrail. Note that the <br /> handrails included the required extensions under the previous permit B1601-014. The <br /> railing shall be shown if existing or added. The construction, whether new or existing, shall <br /> extend horizontally over the top and bottom landings for a minimum of 12 inches. See IBC <br /> Section 1014.6. <br /> Response: <br /> The Floor Plan drawing has been corrected to include extensions of the northeast and <br /> southwest ramp handrail as required under the previous permit B1601-014. The railing shall <br /> extend horizontally over the top and bottom landings for a minimum of 12 inches. See sheet A- <br /> 0.1. <br /> O523 61'ST SE 0 425.879.3437 © brianbodge@msn.com <br /> Everett, WA 98203 <br /> 071-0) <br />