Mr. Drew Martin <br /> Plan Check Number: B1901-029, First Building Review Letter Response <br /> April 30, 2019 <br /> Accessibility: <br /> 6. The project involves Level 2 Alterations to the building per IEBC Chapter 8, Accessibility <br /> improvements per IEBC Section 7052 shall be included in the project. Potentially <br /> inaccessible elements include, but are not limited to, the bathrooms, stairs, ramps, entryway <br /> doors, and parking. Where the building is made to be less than fully-accessible per one of <br /> the exceptions, documentation substantiating the limited accessibility improvements shall be <br /> submitted for review. See IEBC Section 806.1. <br /> Response: <br /> A new accessible restroom is proposed, a new interior ramp is proposed to provide required <br /> accessibility at entry door. Additional dimensions and information on the existing ramp, landing <br /> and handrails have been added to the drawings. See sheets A-0.1, A-1.1 &A-1.2. The existing <br /> van accessible parking space is reflected on sheet C-1.0. <br /> 7 SheetA-1.1 specifies installation of new Door D1O2, The doorway and exterior landing shall <br /> be modified to provide the required maneuvering clearance per ICC A117.1-09 Section <br /> 404,23.2 and Figure 404.2.3.2(f); the Door Schedule shall state in the notes that a door <br /> closer shall not be provided unless a minimum 54-inch width is provided. Alternatively, the <br /> door swing may be reversed to provide the maneuvering clearance per Figure 4O4.2.3.2(g); <br /> the door loser shall similarly not be provided. See IEBC Sections 806.1 and 705.1, and IBC <br /> Section 1101.2, <br /> Response: <br /> Dimensions have been added for the exterior landing to clarify existing conditions, maneuvering <br /> clearance has been called out. No door closer will be provided, note has been added. See sheet <br /> A1.1 DOOR & HARDWARE NOTES. <br /> 8. The Basement Floor Plan throughout the construction drawings indicates that the ramp does <br /> not include extensions of the northeast and southwest ramp handrail. Note that the <br /> handrails included the required extensions under the previous permit B1601-014. The <br /> railing shall be shown if existing or added. The construction, whether new or existing, shall <br /> extend horizontally over the top and bottom landings for a minimum of 12 inches. See IBC <br /> Section 1014.6. <br /> Response: <br /> The Floor Plan drawing has been corrected to include extensions of the northeast and <br /> southwest ramp handrail as required under the previous permit B1601-014. The railing shall <br /> extend horizontally over the top and bottom landings for a minimum of 12 inches. See sheet A- <br /> 0.1. <br /> O523 61'ST SE 0 425.879.3437 © brianbodge@msn.com <br /> Everett, WA 98203 <br /> 071-0) <br />