t� <br /> :ry <br /> 9.0 Poundations <br /> ;� <br /> Sprcad fooiings may be uscd for buildin�� siq�•port when founded on the dense, native sediments or <br /> stnictural fili placed as previously discussed, or on Cooting trenches as discusse�l in Section 9.1 for <br /> � footings requiring overezcavation. Footin�s will require overexcavation of approsimately siz feet <br /> down to native dense soils in the vicinity of EP-6 at the west end of proposed building A, The Site <br /> and Exploration Plan, Figure l, shows the approximate limit ofoverexcavation in this area. <br /> � Footings requiring overexcavation may be extendr.d down to native soils, or structural fill should be <br /> placed in 8 inch thick lifts compacted to 95% of ASTM: D1557 over the native soils up to footing <br /> � elevations. Based on the finished tloor elevations shown on the preliminary site plan, footings for <br /> buildings B, C, D, and the east end of building A can be founded on near surface dense native soil <br /> or structtual fill placed on dense soils. It is possibic [hat additional isolated areas of fill and soft soils <br /> � exist, that were not found during our investigation, due ro past grading and existing structures. <br /> Therefore, it is imperative that all footing excava[ions be evaluated by a representative of our firm, <br /> to deter.mine if additional overexcavation is required. <br /> � We recommend that an allowable foundation soil bearing pressure of 2,500 pounds oer square foot <br /> (ps� be utilized for design purposes, inciuding botlt dead and live loads. An increase of one-third <br /> � may be used For sliort-term wind cr seismic loading. Perimeter footings should be buried at least <br /> IS inches into the surrounding soil for frost protection; interior f::otings require only 12 inches <br /> burial. However, all footings must penetrate to the prescribed bearins;stratum(ur structural fil]) and <br /> � no footing should be founded in or above loose or highly organic material. r111 footings should have <br /> a minimum width of 18 inches for the one-story struchtre. <br /> iAnticipated settlement of footines founded on the approved bearing st:atum should be on the order <br /> of one inch or less. Ho�vever, loose soii not removed from beneath the footing excavations or <br /> � recompacted prior to footing placement could result in increased settlement. .411 footing areas should <br /> be inspected by a represen[ative of our firm prior to placing concre[e to verify that the soil conditions <br /> are as assumed in this report and that construction confom�s to the recommendations contained in <br /> � this report. Such ir_spections may be required by the governin� municipality. Perimeter footing <br /> drains should be provided, as discussed under the section on Drainage Consideratio�.s. <br /> t9.1 Footing Trenches <br /> As a�t altemative to backfilling overexcavated foo[ing trenches with structural fill, footing trenches <br /> � backfilled with controlled density filUlean mix concrete(CDF) that extend down to ''�e glacial till <br /> may be used for foundation support. <br /> � The trenches should have a minimum width equa( to the width of the footings plus at le:ut 6 inches <br /> on each side of the footing (or as designated by the Pield EngineedEngineering Geologist) and be <br /> excavated down to the dense natural soils. Because of the potential for caving, the actual trench <br /> ' width may be greater than specified. The use of a larger, track-mounted backhoe will geatly speed <br /> _, trench excava[ion over the use of a conventional, rubber-tired backhoe. In order to reduce <br /> disturbance of the bearing soils exposed in the trench, it is strongly recommended that the teeth of <br /> ' the backhue bucket be co��ered with a smoodi cutting edge. <br /> � ��� <br /> ' MAYES :ESTING ENG/NEERS <br />