Laserfiche WebLink
Structural <br /> 3. On details 2/S602, 3/S602, and 11/5602, it appears that the existing footings are being <br /> undermined in order to install the new footings. Please clarify. Please address this <br /> condition as the size of the new footing will now bear part of the existing building as <br /> well as the load from the proposed building. Please verify that the existing footing can <br /> bear additional load when the new footing is being installed beneath the existing as <br /> well as meeting compaction requirements to install the new footing beneath the <br /> existing. <br /> If you have any questions, please email or call me at (425) 257-7287. Upon submittal of the <br /> drawings, your application will be given priority and plan reviews will recommence. All required <br /> submittals shall be sufficient detail and contain sufficient information to ensure that the proposed <br /> structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> 40,L <br /> James Bronder, PE <br /> Associate Engineer <br /> Plans Examiner <br /> Tony Lee <br /> Building Official <br /> ( 4 of 4 y.) <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8857 <br />