Mr. Randy Heltne <br /> Everett Housing Authority <br /> Plan Check Number: B1807-032, Second Review <br /> October 17, 2018 <br /> wood sill plate, must be naturally-durable or preservative-treated wood if the clearance from <br /> top-of-wall to soil is less than 8 inches or the clearance from top-of-wall to concrete sidewalk is <br /> less than 2 inches. The construction drawings shall be reviewed and revised to be consistent, <br /> and provide additional changes as required based on the intended construction. See IBC <br /> Sections 107.2.1, 1012, 2304.12.1.2 and 2304.12.1.5. <br /> 23. No additional comment. <br /> 24. No additional comment. <br /> 25. No additional comment. <br /> Energy: <br /> 26.This comment has not been completely addressed. The original comment stated that R-10 <br /> foundation insulation is required for a depth of 24 inches below the top of the slab. The <br /> response states that Section B-B/A-6 has been revised to specify the insulation. However, <br /> Detail 7/S3.1 is not consistent with Section B-B/A-6, and will not provide the required depth <br /> depending on the height of the stem wall. The construction drawings should be revised for <br /> consistency. The thermal break between the slab and foundation wall should be specified in <br /> Detail 7/S3.1 to ensure it is constructed properly. See WSEC-15 Table C402.1.3. <br /> Miscellaneous: <br /> 27. No additional comment. <br /> 28. No additional comment. <br /> 29. No additional comment. <br /> 30.This comment has not been completely addressed. A note has been added to Sheet A-2 <br /> requiring the floors to have a non-absorbent surface per IBC Sections 1210.2.1. The note shall <br /> be revised to also required the walls to be non-absorbent per Section 1210.2.2. See IBC <br /> Section 107.2.1. <br /> 31.This comment has not been completely addressed. The multi-use room on Sheet A-2 appears <br /> to include a domestic oven-range appliance with a hood. A note shall be added specifying the <br /> appliance as a domestic oven-range. The note shall limit the use of the appliance to boiling, <br /> steaming, and warming precooked food. See IMC Table 507.1.2"Community"Spaces Type 1. <br /> Additional Comments: <br /> 32. Structural drawings have been added to the construction drawing set that were not included in <br /> the original submittal. The architectural drawings include structural information that duplicates <br /> or differs from information provided in the structural drawings. A note shall be provided on <br /> Sheet A-0 stating: "The architectural drawings include structural information that is duplicated <br /> Page 4 of 10 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257-88 <br />