Laserfiche WebLink
V <br /> Plan Check#B1807-032 <br /> Page ' <br /> 28. The ground floor bathrooms on Sheet A-2 shall have ventilation per IMC 403.3.1.1 and Table <br /> 403.3.1.1. The construction drawings shall be revised to the existing systems or indicate new <br /> system components satisfying these requirements. See IBC 1204.1. <br /> The new ground floor toilet rooms require ventilation fans of 50 cfm. This is noted on Sheet A- <br /> 2. <br /> 29. The building shall meet meet the ventilation and heating requirements of IBC Sections 1203.1 <br /> 1204.1. The construction drawings shall specify modifications to the existing systems or indicate <br /> new system components satisfying these sections. See IBC Section 107.2.1. <br /> The existing building is heated by electric baseboard panels. The new addition will also be <br /> heated by electric baseboard. The ventilation requirements are noted on the floor plan on <br /> Sheet A-2. <br /> 30. The floors and walls in the ground floor bathrooms on Sheet A-2 shall have a non-absorbent <br /> surface per IBC Sections 1210.2.1 and 1210.2.2, respectively. Modification to the main floor <br /> bathrooms on Sheet A-1 shall similarly satisfy these sections. The construction drawings shall be <br /> revised to specify the required finish materials. See IBC Section 107.2.1 <br /> • The floors on the main floor do have non-absorbent surfaces per IBC Sections 1210.2.1 and <br /> 1210.2.3. The new toilets on the ground floor will have non-absorbent surfaces as noted in <br /> Sheet A-2. <br /> 31. The multi-use room on Sheet A-2 appears to include a domestic oven-range appliance with a <br /> hood. The hood shall comply with IMC Section 57.1.2 and Table 47.1.2. The proposed us of the <br /> oven shall be clarified, and the corresponding hood required (i.e., residential or Type I)shall be <br /> indicated in the construction drawings. If a residential hood is provided,the minimum exhaust <br /> rate shall be as specified for kitchens in private dwellings per Table 403.3.1.1. <br /> A residential hood fan will be used and have a 100 cfm per table 403.3.1.1 in IMC.This is noted <br /> on ground floor plan Sheet A-2. <br /> Sincerely, <br /> Charles E. M ran <br />