Laserfiche WebLink
Geologically Hazardous Areas; Geotechnical Letter <br /> Kennedy Single Family Residence <br /> 3815 Shore Avenue <br /> March 23, 2018 <br /> RN File No. 3279-001A <br /> Page 8 <br /> foundation excavation prior to placing concrete. Loose or disturbed soil was observed in the <br /> explorations to depths of approximately 4 feet. <br /> For foundations constructed as outlined above,we recommend an allowable design bearing <br /> pressure of 2,500 pounds per square foot (pal) be used for the footing design, IBC guidelines <br /> should be followed when considering short-term transitory wind or seismic loads. Potential <br /> foundation Settlement using the recommended allowable bearing pressure is estimated to be <br /> less than 1-inch total and 1/2-inch differential between footings or across a distance of about 30 <br /> feet Higher soil bearing values may be appropriate with wider footings. These higher values <br /> can be determined after a review of a specific design. <br /> Lateral Loads <br /> The lateral earth pressure acting on retaining walls is dependent on the nature and density of <br /> the soil behind the wall,the amount of lateral wall movement, which can occur as backfill is <br /> placed, and the inclination of the backfill. Walls that are free to yield at least one-thousandth of <br /> the height of the wall are in an "active" condition. Walls restrained from movement by stiffness <br /> or bracing are in an "at-rest" condition.Active earth pressure and at-rest earth pressure can be <br /> calculated based on equivalent fluid density. Equivalent fluid densities for active and at-rest <br /> earth pressure of 35 pounds per cubic foot (pcf) and 55 pcf, respectively, may be used for <br /> design for a level backslope. These values assume that the on-site soils or imported granular fill <br /> are used for backfill,and that the wall backfill is drained. The preceding values do not include <br /> the effects of surcharges, such as due to foundation loads or ether surface loads. Surcharge <br /> effects should be considered where appropriate. <br /> Seismic lateral loads are a function of the site location, soil strength parameters and the peak <br /> horizontal ground acceleration (PGA) fora given return period. We used the,US Geological <br /> Survey program "U.S. Seismic Design Maps Web Application" to compute the PGA for the <br /> site. The design maps summary report for the 2012/1518C is included in this report as <br /> Appendix A. The above drained active value should be increased by a uniform pressure of 8.5H, <br /> when considering seismic conditions. H represents the wall height.. <br /> The above lateral pressures may be resisted by friction at the base of the wall and passive <br /> resistance against the foundation.A coefficient of friction of 0.5 may be used to determine the. <br /> base friction in the native glacial soils. An equivalent fluid density of 200 pcf may be used for <br /> passive resistance design. To achieve this value of passive pressure, the foundations should be <br /> poured "neat" against the native dense soils, or compacted fill should be used as backfill <br /> against the front of the footing, and the soil in front of the wall should extend a horizontal <br /> distance at least equal to three times the foundation depth. A resistance factor of 0.67 has <br /> been applied to the passive pressure to account for required movements to generate these <br /> pressures. The friction coefficient does not include a factor of safety. <br /> All wall backfill should be well compacted. Care should be taken to prevent the buildup of <br /> excess lateral soil pressures due to overcompaction of the wall backfill. <br /> Robinson Noble, Inc. <br />