My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11611 AIRPORT RD Geotech Report 2018-01-02 MF Import
>
Address Records
>
AIRPORT RD
>
11611
>
Geotech Report
>
11611 AIRPORT RD Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:26:17 PM
Creation date
6/1/2020 1:46:38 PM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11611
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l � <br /> Geotrchnical Gngincering Rcport <br /> Proposed Ahn Warehouse <br /> May I l, 2001 <br /> CG File No. I 121 <br /> Page 10 <br /> dense, or better nahvc soils. The CDF is then placed in the excavation to planned footing <br /> subgrade elevation. Conventional shallow spread fbundauons may then be placed on the CDP <br /> hench. <br /> The hench sidewalls need to stay open for the CDF method to be successful. Severe caving of <br /> the test pit sidewalls was encountered during our explorations, after the test pits were deeper than <br /> about S feet. It would be best to excavate the CDF trenches just prior to or during the placement <br /> of the CDF, as the trenches are not expected?o stay open for an extended period of time. <br /> Design Values for Conventional Shallow Foundations: Footings should extend at least 18 <br /> inches below the lowest adjacent finished ground surface for frost protection and beanng capacity <br /> considerations. Minirrum foundation widths of 16 and 24 inches should be used for continuous <br /> and isolated spread footings,respectively. Standing water should not be allowed to accumulate in <br /> footing trenches. All loose or disturbed soil should be removed from the foundation excavation <br /> prior to placing concmte. <br /> For foundations conswcted as outlined above, we recommend an allowable design bearing <br /> pressure of 2,500 pounds per square foot (ps�be used for the footing design. Ilnifonn Building <br /> Code (UBC) guidelines should be followed when considering short-term transitory wind or <br /> seismic loads. Potential foundat�on settlement using the recommended allowable bearing <br /> pressure is es[imated [o be less than 1-inch total and 1/2-inch differentia] between footings or <br /> across a distance of about 20 feet. Higher soil bearing values may be appropriate for footings <br /> founded on the unweathered very dense till, and with wider footings. These higher values can be <br /> determined after a review of a specific design. <br /> Seismic Design: '1'he site is located within Zonc 3 of the Seismic Zone Map shown as Figure 16- <br /> 2 of the 1997 Uniform Building Code (UI3C). 7'his corresponds to a Seismic Zone Factor, Z, of <br /> 030. This, in tum, corresponds to a honzontal acceleration of P.3 g. SSte conditions best fit the <br /> lII3C description for Soil ProSie"fype Sp("Stiff Soil Prnfile"). <br /> Cornerstone Geotechnical, Inc. ( l �I a� <br />
The URL can be used to link to this page
Your browser does not support the video tag.