NELSON <br /> 2. Continuing with the previous comment, Plan 2/S1.1 shows a limited extent of floor grating <br /> and references the mechanical drawings for additional information. The architectural <br /> drawings shall show the/extend of the intended walking surface, including the stairways and <br /> grating panels intended to be temporarily removable. Where panels are intended to be <br /> removable, guards shall be provided. Details for the connection of the grating to the <br /> structural framing shall be provided. See IBC Section 107.2.1. <br /> Please see our response to the item #1 <br /> 3. The drawings do not include the stairways and intermediate platforms. Elevations, sections, <br /> and details should be provided as needed to clarify the required construction. See IBC <br /> Sections 107.2.1 and 1011. <br /> Please see our response to the item #1. <br /> 4. The structure, including the stairways and intermediate platforms, shall be provided with <br /> guards along all walking surfaces. Details for the design of the guards shall be provided in <br /> the construction drawings. See IBC Sections 505.3.3 and 1015.2. <br /> Please see our response to the item #1. As an additional note to supplement the <br /> structural response, please see 6/S3.1 for the guard rail detail. <br /> 5. The construction drawings shall require a sprinkler system to be installed on all levels of the <br /> structure. See IBC Section 505.3.2. <br /> The Sprinkler system is a deferred submittal as noted on T1.1 under"separate permit <br /> submittals" and will be tailored to meet the code requirements for every area within <br /> the building, including the mechanical mezzanine. <br /> Please see note#13 added to General Notes on sheet A2.1 stating the sprinkler <br /> system requirements for the mezzanine. <br /> Please see attached structural response letter from ENW Structural Engineers dated December <br /> 6, 2018. <br /> We hope this information answers your questions and concerns satisfactorily. Please contact <br /> me to discuss further if you should need additional information or clarification. Thank you for <br /> your attention to this matter. <br /> Respectfully, <br /> a /Amboy/ <br /> m <br /> 3S <br /> Nadia Azarova, AIA <br /> Nelson/ Formerly Craft Architects <br /> a <br /> • <br /> TerraPower Permit#61810-016 review comments response _ PagP2f+f 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.