My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3323 HOYT AVE C D 2020-06-17
>
Address Records
>
HOYT AVE
>
3323
>
3323 HOYT AVE C D 2020-06-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 1:18:37 PM
Creation date
6/17/2020 1:17:48 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
3323
Unit
C D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14641-86-4- P. 9 - <br /> Continuing with the previous comment, the portal frame beams support both gravity and <br /> seismic loads. Calculations substantiating the design of the beams shall be submitted for <br /> review. The seismic loads shall include holdown forces at Grids A.5/1.5 and A.5/4.5 from <br /> the second story shearwalls. The holdown forces shall include overstrength per ASCE 7-10 <br /> Section 12.3.3.3. The design shall include the seismic load combinations per Section <br /> 12.4.3.2. See IBC Sections 1604.1, 1604.4, and 1613.1. <br /> Response: <br /> The portal frame supports lateral loading but not vertical loading. There is a girder joist <br /> supporting loads from above. See attached APA technical data and supplemental <br /> clarifications for requested portal frame engineering design capacity. <br /> .6.The wood shear walls appear to be missing holdowns at the ends of multiple walls on <br /> Sheets S-4.0, S-5.0, and S-6.0. Holdowns shall be provided connecting the boundary <br /> elements (i.e., studs at the wall ends) across floor framing and to the foundation at all wall <br /> ends. Calculations substantiating the design of the holdowns and boundary elements <br /> should be submitted for review. See IBC Sections 1604.1, 1604.8.1, 1604.10, 2304.10.6, <br /> and 2306.1, and NDS-15 SDPWS Sections 3.4, 4.L4, and 4.3.6.4.2. <br /> Response: <br /> Hold-downs have been provided at locations uplift is occurring. See prior as well as. <br /> attached hold-down and uplift tabulations included in woodworks analysis as well as <br /> Simpson strong-tie hold down information for the requested calculations clarifications and <br /> supplemental information. <br /> 27 Hold-downs connecting to the concrete foundation shall comply with the load requirements <br /> of ACI 318-14 Section 17.2.3.4. The design does not appear to consider this criteria. <br /> Calculations substantiating the hold-down design including this criteria shall be submitted <br /> for review. IBC Section 190L2. <br /> Response: <br /> See attached requested supplemental information (Email 5/31/18)from Simpson Strong-tie <br /> (Mr. Jim Benton P.E.) and ESR 2611. <br /> he s`ear was on Grid 3 are 5-is- <br /> discontinuous to the foundation, resulting in a Type 4 <br /> �h <br /> Horizontal Structural Irregularity per ASCE 7-10 Table 12.3-1. The first-story wood posts, <br /> wall-to-post connections, wall-to-beam connections, beam-to-post connections, post-to- <br /> foundation connections, and foundations on Grid 3/C-E shall be designed considering the <br /> over-strength factor per Section 12.3.3.3. The design shall include the seismic load <br /> combinations per Section 12.4.3.2. The design shall provide a complete load path to the <br /> foundation. See IBC Sections 1604.2, 1.604.4, and 1613.1. <br /> Response; <br /> See attached requested supplemental calculations per your request <br /> 817 Metcalf Street, Suite 207 <br /> Office: 360.855.2333 Ext. 207 <br /> Sedro-Woolley,WA 98284 Cell: 360.982.0928 <br />
The URL can be used to link to this page
Your browser does not support the video tag.