My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD 2020-09-18
>
Address Records
>
RIVERSIDE RD
>
607
>
607 RIVERSIDE RD 2020-09-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2020 2:41:10 PM
Creation date
7/2/2020 11:14:34 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Notes
WO 3591-02
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
525
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iii. C2.2: <br /> 1. Please include the City's standard storm drainage notes. <br /> PORT RESPONSE: City's standard storm drainage notes have been added. <br /> iv. C3.5: <br /> 1. The existing catch basin in the 8th St ROW must be removed and the <br /> associated storm drainage pipes abandoned appropriately. Storm <br /> drainage structures within the trail easement should also be <br /> removed. <br /> PORT RESPONSE: Note added to plans to remove catch basin and abandon <br /> associated storm drainage pipes. <br /> v. C4.0: <br /> 1. Because maintenance of the CDS unit requires the unit to be drained, <br /> and because the outlet pipe of the CDS unit will be submerged and <br /> below the normal water elevation in the pond, a gate valve or some <br /> other means of"closing off"the pond from the unit must be provided <br /> in order for maintenance of the unit to be effectively accomplished in <br /> the future. <br /> PORT RESPONSE:A gate valve has been added to the outlet pipe of the CDS <br /> unit. <br /> vi. C4.4: <br /> 1. Please extend the drawing to the southern end of the pavement. <br /> Please also include notes stating that runoff from Lot 8,to the east <br /> and south of Riverside Rd, shall not be allowed to enter the road— <br /> and include measures to prevent this from occurring (such as an <br /> asphalt lip across the southern end of the road pavement). Please <br /> also indicate that the pipes coming into CB#30 from the east and <br /> south are plugged. <br /> PORT RESPONSE: Drawing viewport has been extended to show the south end <br /> of existing pavement. Measures to prevent runoff from the specified areas and <br /> associated notes have been added to the plans. Note has been added for CB <br /> #30 regarding plugged pipes. <br /> 2. Some of the information given on the profile view for CB#28A <br /> doesn't make sense—isn't there just one pipe coming in from the <br /> east,that is, a 6" force main? <br /> PORT RESPONSE: CB#28A has 12"gravity storm drain pipes connected from <br /> the north and south,which are shown on sheet C4.4 in the profile for the <br /> gravity storm drain system on Riverside Road.The 6"storm drain force main <br /> from the east is shown on sheet C4.5 in the profile for the storm drain system <br /> coming from 8th street. The respective callouts have been revised for clarity. <br /> vii. C4.5: <br /> 1. For clarity, please do not show any demolished storm drainage <br /> infrastructure on this sheet—such as the underdrain, associated catch <br /> basin and outlet pipe in 8th St near proposed CB#5. <br />