My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
R L Alia Company 12/7/2020
>
Contracts
>
Capital Contract
>
R L Alia Company 12/7/2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2021 1:38:29 PM
Creation date
12/9/2020 12:33:15 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
R L Alia Company
Approval Date
12/7/2020
Council Approval Date
11/10/2020
Department
Public Works
Department Project Manager
Tom Fuchs
Subject / Project Title
Jackson Park Area Stormwater
Public Works WO Number
UP3703
Tracking Number
0002555
Total Compensation
$12,326,000.00
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
R.L. Alia Company 5/4/2021 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
407
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS <br /> DIVISION 1 —GENERAL REQUIREMENTS- <br /> Section 1-02.4, Examination of Plans, Specifications, and Site Work, page SP-44, 1- <br /> 02.4(1) General, Bid prices shall reflect: First paragraph last sentence: Delete reference <br /> "...all necessary testing services."The City will furnish all testing services that are referenced in <br /> City standards, specifications and plans or otherwise needed to meet project requirements and <br /> address field conditions. <br /> Section 1-05.18(1) page SP-69, Contractor's Representative- <br /> Second paragraph references to 'full-time basis"for contractor's project manager and <br /> superintendent shall be revised to read"part-time basis". <br /> Section 1-08.4(3), page SP-99, Special Construction Constraints- <br /> Add the following constraint to the list: <br /> 8. The contractor shall plan, schedule and construct the new stormwater collection network <br /> beginning with the most downstream structures and pipe and then continue upstream. However, <br /> the contractor may construct new conveyance stormwater pipe elsewhere but but leaving the <br /> inlets connected to the sewer. If stormwater is introduced into the new system prior to the <br /> treatment units being functional, the contractor shall bypass stormwater flows to the existing <br /> sewer system adjacent to the treatment site and less than 100 feet away. Otherwise, estimated <br /> stormwater flow rates in the new system are as follows: <br /> If upstream inlets are connected 2-Year Storm Event 25 Year Storm Event <br /> Downstream of SD Manhole: CFS GPM CFS GPM <br /> SDMH 01 1.1 500 2.3 1050 <br /> SDMH 02 1.6 700 3.3 1500 <br /> SDMH04 2.4 1100 5.2 2300 <br /> SDMH 05 0.9 400 1,9 850 <br /> SDMH 08 7.8 3500 16.4 7400 <br /> SDMH 09 8.0 3600 16.9 7600 <br /> AB other requirements of the contract documents remain in effect. <br /> City of Everett �Z� R V , <br /> o <br /> j,- <br /> 1., <br /> y David Voigt, P.E. e. <br /> Project Manager : 2g424 9 .• <br /> *S16ALE 1*1 <br /> Addendum 2 Page 2 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425)257-8800 • Fax(425)257-8882 <br />