My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 3RD FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
3RD FLOOR
>
1321 COLBY AVE 3RD FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:23:14 AM
Creation date
1/14/2021 3:05:12 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
3RD FLOOR
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> c (• <br /> - <br /> Ltr. B0206-022 <br /> July 17, 2002 <br /> Page 2 <br /> 4) Signed and sealed structural calculations should be submitted for the new window <br /> opening shown on Sheet A8.02. The listing of the reinforcement shown should be <br /> submitted for review. Any special inspections required should be noted on the cover or <br /> code data sheet. <br /> 5) Detail 2/A8.02 shows a conventional lintel for a new window and not the reinforced fiber <br /> mesh shown in Detail 4/A8.02. The intended method should be clarified. <br /> Occupancy <br /> 1) A minimum one-hour occupancy separation should be shown around Soiled Storage room <br /> B329. Section 308.8&3-C <br /> 2) Soiled Utility room doors B325, B329 and C347 should be minimum one-hour doors per <br /> Section 308.8 &Table 3-C. <br /> 3) If rooms B323, B341 and C309 are used for storage of combustible materials (even <br /> partially), then they should be shown separated by minimum one-hour occupancy <br /> separations per Table 3-C from the remainder of the building: <br /> i) Doors should be a minimum 60-minute fire-rated assemblies. Section 302.3 <br /> ii) Walls should be shown as minimum one-hour fire-resistive construction with <br /> listed wall types ke):d into the plans. Section 302.3 <br /> 4) The wall type (one-hour) for the new smoke barrier wall on the North side of Room B328 <br /> should be shown on the plans(Sheet A2.3B). Section 308.2.2.1 <br /> Exiting <br /> 1) The door schedule must be included on the plans. Section 106.3.3 <br /> 2) Doors B350, C319, C317, C321 C327, C328 (and the roll-down fire shutter) are suite <br /> doors should be shown as minimum 60-minute fire-rated assemblies. Section 1007.5.9.1 <br /> 3) Doors installei in a smoke barrier that arc across a corridor should be a pair of opposite- <br /> swinging doors without a center mullion. This effects doors C343 and the existing doors <br /> at the West end of Corridor C301. Section 308.2.2.1 <br /> 4) The North all of Room B326 is a corridor wall and should have the fire resistance <br /> continue to the underside of the floor structure above. Section 1004.3.4.3.1 <br /> 5) Toilet room door C335 should either be a 20-minute door, or comply with Section <br /> 1007.5.4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.