My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 3RD FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
3RD FLOOR
>
1321 COLBY AVE 3RD FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:23:14 AM
Creation date
1/14/2021 3:05:12 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
3RD FLOOR
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C . <br /> Ltr. B0206-022 <br /> July 17,2002 <br /> Page 3 <br /> 6) It should be shown that the 'slide/swing' type doors (Door type F) used for some patient <br /> rooms adjoining a corridor are tight fitting, smoke- and draft-control assemblies and are <br /> provided with positive latches (roller latches are prohibited) as per Exceptions 3 & 6 to <br /> Section 1007.5.4. A cut sheet should be provided. <br /> 7) Glazing type WF in Room C305 should be shown to be either 45-minute, fixed fully- <br /> tempered, or laminated glass. Section 1007.5.4, Exception 4 <br /> Accessibility <br /> 1) The hot water supply and drain for accessible lavatories should be shown recessed, <br /> insulated or guarded against contact. Section 1106.11.7.4 <br /> 2) The accessibly transfer shower in room C326 should comply with the following criteria: <br /> i) A folding or fixed scat should be provided per Section 1106.11.10.3: <br /> (a) Should be mounted not less than 17 inches and nor more than 19 inches <br /> above the floor. should be provided. <br /> (b) Should be L-shaped and extend the full depth of the stall. <br /> (c) The leading edge of the scat may be set back not more than 1 1/2 inches <br /> from the leading edge of the shower stall (not along the back wall as <br /> shown). <br /> (d) The size of the seat should conform to Section 1106.11.10.3. <br /> ii) The shower controls: • <br /> (a) Should be mounted on the wall opposite of the seat. Section 1106.11.10.3 <br /> (b) Should be located within 18 inches of the open side of the shower stall (not <br /> along the back wall as shown). Section 1106.11.10.5 <br /> iii) The half-height wall must continue to a height above the seat back or controls. <br /> iv) The floor should be sloped to drain with a flush or beveled threshold (maximum <br /> edge height of%inch and maximum slope of IV: 2H. Section 1106.11.10.6 <br /> v) The location of the seat should be along the East wall to provide for the 12" <br /> minimum clear floor space extension as noted in Section 1106.11.10.2 • <br /> 3) The transfer _Flowers in rooms B352 and B353 should also comply with Section <br /> • <br /> 1106.11.10 <br /> 4) If the rooms in the C Wing are used for patient care which specializes in treating <br /> • <br /> conditions that affect mobility, than all rooms must be accessible per Section 1103.1.6: <br /> i) The in-room toilets must be provided with grab bars that comply with Section <br /> 1106.11.5.3. <br /> ii) The lateral distance from the center line of the water closet to the nearest side wall <br /> (excluding grab bars) must be 18 inches. Section 1106.11.5.1 <br /> 7y • <br /> • <br />
The URL can be used to link to this page
Your browser does not support the video tag.