My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9600 SHARON DR EXPLORER MIDDLE SCHOOL 2016-05-27
>
Address Records
>
SHARON DR
>
9600
>
MSD TEACHING AND LEARNING CENTER
>
9600 SHARON DR EXPLORER MIDDLE SCHOOL 2016-05-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2019 3:55:58 PM
Creation date
5/27/2016 10:52:21 AM
Metadata
Fields
Template:
Address Document
Street Name
SHARON DR
Street Number
9600
Tenant Name
MSD TEACHING AND LEARNING CENTER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
339
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P1 <br /> engineering pl c <br /> Figure 2.2 was used to determine if any additional requirements apply.The proposed <br /> improvements will not exceed 50% of the assessed value of existing site improvements therefore <br /> no additional requirements are applicable. <br /> Minimum Requirements for this project: <br /> • Minimum Requirement#1: Stormwater Site Plan Preparation <br /> This document is the Stormwater Site Plan. It outlines the existing and proposed site and <br /> drainage conditions, describes the flow control systems,and presents the stormwater <br /> analysis. <br /> • Minimum Requirement#2: Construction Stormwater Pollution Prevention <br /> The CSWPP Plan in accordance with Volume II, Chapter 2 of the 2010 City of Everett <br /> Stormwater Management Manual is included in Section IV of this report. <br /> • Minimum Requirement#3: Source Control of Pollution <br /> There are sources of pollutants proposed as part of this project. Runoff from these surfaces <br /> will be treated in accordance with Volume IV of 2010 City of Everett Stormwater <br /> Management Manual.These are outlined in Section V of this report. <br /> • Minimum Requirement#4:Preservation of Natural Drainage Systems and Outfalls <br /> The proposed drainage system maintains the existing flow distribution from the two <br /> threshold discharge areas and maintains the discharge points from the site. <br /> • Minimum Requirement#5: On-site Stormwater Management <br /> On-site stormwater management BMPs provided for this project include BMP 12.20 Soil <br /> Amendments,Quality and Depth,BMP 12.50 Downspout Dispersion Systems and BMP <br /> 12.70 Sheet Flow Dispersion. <br /> • Minimum Requirement#6: Runoff Treatment <br /> The project proposes less than 5,000 square feet of new and replaced pollution generating <br /> surface,therefore runoff treatment is not required. <br /> • Minimum Requirement#7: Flow Control <br /> Table 2.2 Flow Control Requirements by Threshold Discharge Area states that flow control <br /> facilities are only required for threshold discharge areas with more than 5,000 square feet <br /> of net new impervious surface. Due to the large quantity of removed impervious surface in <br /> each threshold discharge area,neither area meets this criterion,therefore flow control <br /> facilities are not proposed. <br /> • Minimum Requirement#8: Wetlands Protection <br /> There are no wetlands located within the site. <br /> • Minimum Requirement#9: Operation and Maintenance <br /> See Section VIII.G of this report for the Operation and Maintenance Plan for the proposed <br /> stormwater management systems. <br /> LPD Engineering, PLLC Page 5 Mukilteo School District Teaching and Learning Center <br /> Stormwater Site Plan,July 22, 2014; Revised August 25, 2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.