My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY 2022-05-23
>
Address Records
>
EVERGREEN WAY
>
8417
>
8417 EVERGREEN WAY 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:28:37 AM
Creation date
1/28/2021 9:01:05 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Mr. McIlvain <br /> CRM Architects&Planners, Inc. <br /> Plan Check Number: B1805-010, First Review <br /> August 1, 2018 <br /> included. Based on Section 27.2, the nominal wind base shears are approximately 50 kips and <br /> 80 kips, which exceed the values of 34.7 kips and 58.1 kips in the calculations. See IBC <br /> Section 1604.4 and 1609.1. The following comments should be addressed: See structural <br /> response letter <br /> a. The procedure used to determine the wind loading should be clarified. The notes on Sheet <br /> SO.0 should be revised as needed. <br /> b. Calculations substantiating the base shear in each direction using the wind pressures of the <br /> selected procedure shall be submitted for review. If the procedure in IBC Section 1609.6 is <br /> used, calculations for the wind pressures shall be included. <br /> c. Wind pressures on the parapets for the selected procedure shall be calculated at the <br /> parapet height and for both the windward and leeward side. See ASCE 7-10 Section 27.4.5 <br /> as an example. <br /> 23.The distribution of the wind forces to the shear wall lines appears to be based on tributary <br /> widths only and does not include torsion. The lateral wind loads shall include torsional effects <br /> as required by the selected procedure. Forces shall be increased in each line as required. See <br /> IBC Sections 1609.1 and 1609.6.4.1, and ASCE 7-10 Figure 27.4-8 and 28.4-1. See structural <br /> response letter <br /> 24. Sheet S2.0 specifies shear wall Mark 3 for the walls on Grids 1 and 4, identified in the <br /> structural calculations as SW1, SW2, and SW3. The calculations indicate a maximum 3-inch <br /> edge nail spacing. Mark 3 specifies a 4-inch spacing. The shear wall specifications on Sheet <br /> S2.0 should be revised. See IBC Section 1603.1. See structural response letter <br /> 25.The design shear wall load in the"Shear Resisting System Geometry"schedule for Wall SW3 is <br /> 15.1 kips. The input load in the spreadsheet for this wall is 13.9. The wall design should be <br /> revised. See IBC Section 1604.2. See structural response letter <br /> 26.The calculation of the holdown forces is included in the shear wall design spreadsheet. The <br /> following comments should be addressed: See structural response letter <br /> a. The holdown force includes the entire dead load in resistance. The force shall consider . <br /> 0.6D per IBC Equation 16-15. <br /> b. The holdown force based on seismic loading shall be calculated per IBC Equation 16-16. <br /> The dead load component shall be further reduced considering vertical effects per ASCE 7- <br /> 10 Sections 12.4.2.2 and 12.4.2.3 Equation 8. The earthquake component shall be <br /> increased per ACI 318-14 Section 17.2.3.4.3; see the following comment for additional <br /> information. See IBC Section 1604.10. <br /> 27.The shear wall holdown design should be performed for the earthquake loading. The <br /> earthquake component of the holdown forces exceeds 20% of the total uplift. The earthquake <br /> component shall be increased per the provisions of ACI 318-14 Section 17.2.3.4.3. In <br /> addition, the anchorage utilizies post-installed anchors and shall satisfy the provisions of <br /> Section 17.2.3.3. Revised calculations substantiating the holdown design should be submitted <br /> for review. See IBC Sections 1604.10 and 1901.2. See structural response letter <br /> 28.The shear wall holdown anchors are specified on Sheet S1.0. See IBC Section 107.2.1. The <br /> following comments should be addressed: See structural response letter <br /> Page9o,1-1"/TN) <br /> � <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 25 857 — <br />
The URL can be used to link to this page
Your browser does not support the video tag.