The wheel chair lift does not provide access through the fire wall. Access to <br /> and from the wheelchair lift is through door 115A, which is listed as a 90- <br /> minute fire rated door on the door schedule on sheet A9.1 . <br /> 5) The glazed openings within the fire wall as shown on the north elevation <br /> require 90-minute fire-resistive protection. <br /> Sheet A1.3 - Add keynote 1 .3 "EXISTING WINDOW TO BE REMOVED. <br /> INFILL OPENING WITH BRICK TO MATCH EXISTING." <br /> Sheet A4.1 - Add keynote 4.11 "EXISTING WINDOW TO BE REMOVED. <br /> INFILL OPENING WITH BRICK TO MATCH EXISTING." <br /> 6) As the fire wall turns north from Grid line B to Grid Line 8 it should continue <br /> vertically until the edge of the eave over hang. See exceptions in Section <br /> 706.5.2. <br /> Sheet A1.1 - Add wall type D6 callout. <br /> - Add dimension to read " EXTENT OF 2HR BRICK VENEER" <br /> Sheet A8.0 - Add wall type D6 - 2HR BRICK VENEER <br /> Egress: <br /> 1 ) The location and nomenclature of the maximum occupant load signs for the <br /> assembly spaces should be shown on the plans. Section 1004.3. <br /> Sheet G1.1 - Add note - "MAXIMUM OCCUPANT LOAD SIGN PER IBC <br /> SECTION 1004.3. SIGN TO READ "NOTICE FOR YOUR SAFETY <br /> OCCUPANCY IS LIMITED TO 890 PERSONS BY ORDER OF THE CODE <br /> OFFICIAL. KEEP POSTED UNDER PENALTY OF LAW."" <br /> 2) A sign stating Exit in raised characters and braille and complying with ICC <br /> Al 17.1 should be shown adjacent to the exterior exit doorways. Section <br /> 1013.4. <br /> Sheet G1 .1 - Add note "EXIT SIGN W/ RAISED CHARACTERS AND <br /> BRAILLE PER IBC SECTION 1013.4 AND ICC A117.1 ." <br /> 3) All of the exit doors should be shown with panic hardware on the door <br /> schedule. <br /> Sheet A9.1 - Add note in remarks column of door schedule for doors 101 B, <br /> 101 C, 111C, 111 D, 121A, to read "PROVIDE PANIC HARDWARE" <br /> 4) The treads in stair detail 4/A8.6 should be shown to be a minimum of 11 " of <br /> run. Section 1011 .5.2. <br /> Sheet A8.6 - Detail 4 shows the tread depth to be 11" minimum. <br /> 5) Handrails should be detailed on the plans in accordance with Section <br /> 1014.6. <br /> _3/5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.