Laserfiche WebLink
/ 5. The elevator cab should have interior dimensions to show the clear space to accommodate an ambulance <br />stretcher, 24 by 84 inch, per Everett Municipal Code modifications to IBC section 3002.4. <br />We concur — Ref. revised 2/A461 for details <br />6. The star of life should be detailed on the elevator elevations, per Everett Municipal Code modifications to <br />IBC section 3002.4, as well as other elevator requirements identified in ICC A117.1-2009 section 407. <br />Ref. Sheet A462 Note 3. <br />7. Please identify the venting for the elevator machine room, per IBC section 3005.2 as amended by the State <br />of Washington. <br />Elevator and Mechanical systems are deferred submittals. <br />✓ 8. Please coordinate the double check detector access and size requirements with Public Works plan review <br />and the Fire Department. <br />Fire Sprinklers & Fire Alarm are deferred submittals <br />9. Please dimension the 48-inch clearance required between doors at the vestibules, per IBC section 1010.1.8. <br />We concur— Ref. revised 1/A121 for details <br />10. It is not apparent that the roof has overflow drainage provisions per IBC Section 1503.4.1. Please identify the <br />primary and secondary roof drainage systems on the roof plan, per UPC sections 1101.11.1 and 1101.11.2. <br />We concur — Ref. revised 1/A141 roof drain locations and 6/A503 <br />11. Please indicate the permanent access to the roof, per IMC section 306.5, as amended by the State of <br />Washington. <br />We concur. — Ref. revised A122 for location <br />12. Please identify safety glazing on doors on sheet A601, window schedules or elevations as required by IBC <br />section 2406.4. <br />We concur— Ref. General Note at A601. <br />Accessibility <br />i 1. Please indicate the accessible route to the building for people that arrive by public right of way to the site, <br />per IBC section 1104.1. <br />We concur — Ref. revised A100 for accessible route <br />/ 2. Accessible parking signage should indicate compliance with height and content of signage per ICC/ANSI <br />A117.1-2009 section 502.7. <br />We concur — Ref. 8/A102 for details <br />i 3. Please clarify in section whether there is a curb or it is a flat access for the accessible route to the building. <br />This is a curb Ref. A100 for details <br />4. Please identify all hardware types that are required to be accessible to meet graspability required by IBC <br />section 1010.1.9.1 on the door schedule. Please identify either hardware sets or specific hardware types to <br />demonstrate compliance on the drawings. <br />Ref. revised A601 with hardware accessibility requirement notes added IN General Door Notes #19 which <br />identifies which doors to receive this hardware through Gen Note #10 description. <br />J 5. Elevations and details of the accessible plumbing fixtures are missing from sheets A400 and A700. <br />We concur— Ref. revised A763 for details <br />ARCHITECTURE PLANNING INTERIOR DESIGN Jensen Fey <br />www ienwnfe mm . 7730 T mry Wav ReAmnnd. WA 9R052 - PHONE 425.216.031 R . FAx 425.216.0329 <br />