Laserfiche WebLink
EVERETT <br />WASHINGTON <br />11--yanasrg .R--r <br />CITY OF EVERETT <br />Permit Services <br />C;T- <br />January 21, 2019 �`"� F =ir `I, �w " r <br />Owner: Dosunmu �l <br />Job Address: 6007 Rockefeller Ave MAY 2 Q 2020 <br />Plan Check No: C19011-030 <br />RE: Building Permit Re -review Letter <br />Dear Mr. Dosunmu, <br />CITY OF EVERETT <br />Pel`i'1"Iit Services <br />In response to the application for a building permit, the plans have been examined and you are advised that <br />revisions are necessary before a permit can be issued. Please review and respond to the comments below. <br />$raft ZIN"L„ Q Cl.:' Please provide a section drawing looking parallel to the proposed foundation and the existing <br />4QA +,.X1r+„ foundation along Bedroom 1, Bathroom 7 and Bedroom 2. Show the grade elevation change from <br />the existing foundation to the new foundation and how the new foundation is capable of supporting <br />the existing foundation (if needed). <br />e <br />j� yt�s `�` 2. P m,,i a R-10 i in ulaYo� ith therm re k at h e i er c Itio ed pace in the <br />1� AS 0144,la LA" ;If00011�fl r Ie el i id a sesc�i /detal�'1 speccli I`c to`�tTiis s ctuJree or t Mon �'�� <br />3. Define the thermal envelope at the "Base Plan" level. Is the "Entry Area" at the lower level heated? <br />Is the dumbwaiter inside of the conditioned space? 5'6 pr a�VUP10" I44 "4* � <br />, IW 70 -P4A <br />4. The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the <br />movement of liquids to a drain or toward the main vehicle entry doorway. Show the sloped floors <br />on the foundation plan. 5 "Tws ,p "1b I?V0. ^'A't? op.1w. 2 <br />Sft � LOt4w5. Specify the elevation at the top of the slab in the basement and at the top of all foundation walls on <br />the foundation plan. Include the elevation at the top of the existing east foundation wall. <br />6. Call out location and size of footings required to support the 2 point loads from the 4x4 post adjacent <br />to the fireplace. <br />� r...7. Provide gravity calculation for a multi -span beam at the garage over the water heaters and the man - <br />door into the garage. Provide construction detail to show if the floor joist it supports are attached to <br />the side of the beam or if they rest on top of the beam. <br />Provide a full height building section specific to this structure looking east through the northern <br />garage, water heater, stairs, wetbar, hall and southern garage. Show all components at each floor <br />--(.r y4►'C . level. <br />EwN�5✓' 9. Provide gravity calculations for all of the beams supporting the Main floor. <br />Ae4 cAlfac&I 10. Provide minimum 36" landing at the exterior door on the Base Plan. Provide minimum #4 rebar at <br />a"ka h4 42 4*- . 18" o.c. stubbed out of foundation to resist lateral displacement and settling. <br />11. It appears that there is no footing under the "4 — 2x10 Beam" shown in the Bonus Room. Specify <br />footing size and location on the foundation plan. <br />12. The foundation plan shows "Footing per 1S1" and designates "Detail 1S1" in three separate <br />"} locations. The foundation plan also shows a stepped stem wall in the raised portion of the concrete. <br />Page 1 of 2 <br />�_._ - <br />