411 <br /> Mr. Kurt Nelson <br /> Rice Fergus Miller <br /> Plan Check Number: B2001-027,First Building Review <br /> February 7, 2020 <br /> 11. Enlarged Elevator Plan 2/A40.01 shows the elevator shaft at the Main Level. The Main Level <br /> Framing Plan on Sheet S21.01 specifies HSS columns that interrupt the fire barriers around the <br /> shaft. The columns should be shown in Plan 2/A40.01. The designer-of-record should verify <br /> that the required fire protection is not reduced by the columns interrupting the barriers. See <br /> IBC Sections 3002.1, 713.2, 713.4, and 721.1. <br /> Egress: <br /> 12.The Main Level Plan on Sheet A21.01 includes a new elevator. The elevator should specify <br /> providing a two-way communication system at each landing. See IBC Section 1009.8. <br /> Accessibility: <br /> 13.The Main Level Plan on Sheet A21.01 and the elevations on Sheet A31.01 include new exterior <br /> Door 162. The door is required to be accessible. However, it is provided with less than a 48- <br /> inch clearance to the stair edge. The Door Schedule specifies Hardware Group HW-6; the <br /> group is not defined in the drawings, but anticipated to include a door closer. The minimum <br /> door clearance should be 54 inches. Note that the door is required to be accessible regardless <br /> of whether it is located on an accessible route. See IBC Sections 1101.2 and 1103.1, and ICC <br /> A117.1-09 Figure 404.2.3.2(f). <br /> Energy: <br /> 14. Section 11/A40.01 shows the construction through the roof and walls for the elevator shaft. <br /> See IBC Section 107.2.1, and WSEC Section C503 and Table C402.1.3. The following comment <br /> should be addressed: <br /> a. The wall should specify minimum R-13 plus R-10ci insulation. The four-inch framing is <br /> sufficient for the R-13 insulation; the value should be specified. The continuous insulation is <br /> not included and should be specified. <br /> b. The roof should specify minimum R-38ci insulation. <br /> 15.The Reflected Ceiling Plan on Sheet A22.01 includes four new ceiling daylighting devices. The <br /> drawings should specify a maximum thermal rating of U=0.35 for the devices. See IBC Section <br /> 107.2.1 and WSEC Table C402.4. <br /> 16.The Main Level Plan on Sheet A21.01 and the elevations on Sheet A31.01 include a new <br /> exterior curtain wall at Grid A.1-A.5/5.2-5.6. See IBC Section 107.2.1, and WSEC Section C503 <br /> and Table C402.1.3. The following comments should be address: <br /> a. The drawings should specify a maximum thermal rating of U=0.38 for the windows. <br /> b. The drawings should specify a maximum thermal rating of U=0.60 for the door. <br /> o 3200 Cedar Street 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 0 425.257.8857 fax everettwa.gov/permi s <br /> (age 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.