My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST 9TH FLOOR 2022-01-20
>
Address Records
>
13TH ST
>
1700
>
9TH FLOOR
>
1700 13TH ST 9TH FLOOR 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:05:06 PM
Creation date
5/4/2021 2:09:34 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Tenant Name
9TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT <br />Public Works Department <br />March 6, 2019 <br />Holly Shoubridge <br />Mortenson Construction <br />10230 NE Points Drive <br />Kirkland, WA 98033 <br />Holly.shoubridae@mortenson.com <br />Owner: Providence Health and Services - Washington <br />Job Address: 1700 — 13th Street <br />Plan Check No: B1903-002 <br />RE: Building Permit Review Letter, PRMCE — D Wing LVL 9 <br />Dear Ms. Shoubridge, <br />In response to the application for a building permit, the plans have been examined and you are <br />advised that revisions may be necessary before a permit can be issued. Please review and <br />respond to the comments below. <br />Construction <br />1. UL listing U428 requires proprietary GWB. As generic Type X is not in the listing, the types <br />of approved GWB (mostly Type C) should be shown on the plans for wall types S, T & <br />W/A8.01. <br />a. Note 6 on Sheet A8.01 indicates the requirement of referring to the UL listing for <br />GWB type, however the three partition types above could cause confusion in the <br />field for the building inspectors. <br />2. It is not clear how wall type HcA/A8.01 will provide two-hour fire -resistance as the 2nd <br />layer of GWB needed for 2-hour fire -resistance stops above the ceiling. <br />3. The following comments apply to the horizontal shaft assemblies 17 & 21/A8.01 Listing <br />AER-09038): <br />a. The listing requires Type C GWB vs. the Type X GWB shown on the details. <br />b. Please verify that the studs chosen do not exceed Span Table 1 provided in the <br />listing. <br />4. Shaft detail 16/A8.01 appears to use both UL 469 for the vertical portions and AER-09038 <br />for the horizontal portions of the assembly. Please verify as UL 469 allows Type X GWB <br />for walls however AER-09038 requires Type C for horizontal applications. <br />O 3200 Cedar Street O 425.257.8810 (atlee@everettwa.gov <br />Everett, WA 98201 425.257.8857 fax everettwa.gov , je3) <br />
The URL can be used to link to this page
Your browser does not support the video tag.